6.2 Reading Photometric Reports and IES LM-63 Files

Key Takeaways

  • A Type C plot commonly uses 0° at nadir, 90° at horizontal, and 180° at zenith.

  • Spacing criterion times mounting height above the workplane gives a preliminary spacing check in the specified axis.

  • Absolute photometry already incorporates the optics of the measured complete luminaire.

  • ANSI/IES LM-63 defines electronic transfer of photometric data. Check model, coordinate type, angle grids and input power.

  • Use near-field data or an appropriate optical model when the luminaire is large relative to its distance from the task.

Last updated: November 2026

Every photometric calculation—from manual lumen-method checks to point-by-point software models—relies on data published in a luminaire photometric report and its electronic file. Reading each section accurately and distinguishing relative from absolute photometry prevents costly specification errors.

Core Components of a Photometric Report

Read these common elements in a report or its associated calculation output. Confirm the product identifier and conditions of the test.

1. Candlepower (Candela) Distribution Polar Curve

The candela polar plot graphs luminous intensity (cd\text{cd}) radially from 0 cd0\text{ cd} across vertical angle γ\gamma. In Type C coordinates, 0∘0^\circ is straight down (nadir), 90∘90^\circ is horizontal, and 180∘180^\circ is straight up (zenith).

A circular distribution may have the same pattern in all horizontal planes. A rectangular or asymmetric distribution can vary substantially by direction. Read the specific report’s orientations and consider how the actual fixture will be rotated in the layout. A wallwasher intended to face a wall may perform very differently if the layout uses the photometry with the wrong orientation.

2. Zonal Lumen Summary

The zonal lumen summary tabulates lumens and percentages across standard bands: 0∘0^\circ–30∘30^\circ (nadir task punch), 0∘0^\circ–40∘40^\circ, 0∘0^\circ–60∘60^\circ (useful downward zone), 0∘0^\circ–90∘90^\circ (total downward), 90∘90^\circ–180∘180^\circ (total upward), and 0∘0^\circ–180∘180^\circ (total flux). High output in 60∘60^\circ–90∘90^\circ signals potential direct glare.

3. Utilization data

Use the reported room cavity ratio and reflectance assumptions. In IES terminology, coefficient of utilization (CU) uses reference lamp lumens as its denominator and includes luminaire efficiency. Room utilization factor (utilance) uses delivered luminaire lumens, as for absolute photometry. A report or software may use a generic table label. Identify which lumen basis the values actually use.

4. Luminance and glare data

An average luminance table can help screen high-angle output from specified viewing directions. Confirm the apparent emitting dimensions. An average may hide bright patches or images of individual sources. Evaluate glare for the observer’s position and the method required by the project.

5. Spacing Criterion (SC)

The Spacing Criterion (SC) estimates center-to-center spacing for a regular array based on its direct component at the workplane:

Smax⁡=SC×MHwpS_{\max} = \text{SC} \times MH_{wp}

Always use mounting height above the work plane (MHwpMH_{wp}), not floor-to-ceiling height. Reports can give separate SC values at 0∘0^\circ and 90∘90^\circ. Identify the axis on the drawing before laying out rows.

Worked Example: Spacing Criterion

An office has a 10.0 ft10.0\text{ ft} ceiling, recessed 2×42\times 4 troffers, a 2.5 ft2.5\text{ ft} desk work plane, SC0∘=1.25\text{SC}_{0^\circ} = 1.25, and SC90∘=1.35\text{SC}_{90^\circ} = 1.35. Here MHwp=10.0−2.5=7.5 ftMH_{wp} = 10.0 - 2.5 = 7.5\text{ ft}, giving Smax⁡,0∘=1.25×7.5=9.38 ftS_{\max, 0^\circ} = 1.25 \times 7.5 = 9.38\text{ ft} and Smax⁡,90∘=1.35×7.5=10.13 ftS_{\max, 90^\circ} = 1.35 \times 7.5 = 10.13\text{ ft}. An 8 ft×10 ft8\text{ ft} \times 10\text{ ft} grid fits the estimate when assigned to the respective axes, while 10 ft×10 ft10\text{ ft} \times 10\text{ ft} exceeds it in the 0∘0^\circ direction. Verify actual project performance in the layout.


Relative vs. Absolute Photometry (LM-79)

In relative photometry, the distribution may be referenced to a known lamp output. Compare the documented lamp test basis and any separate ballast correction. If a test with two lamps at 2,950 lm each measures 4,425 lm leaving the luminaire, the optical efficiency in the example is 4,425/(2×2,950)=75%4{,}425/(2\times2{,}950)=75\%.

Absolute photometry reports measured output of the assembled product. A complete unit delivering 4,425 lm and drawing 38.0 W has measured efficacy of 4,425/38.0≈116.4 lm/W4{,}425/38.0\approx116.4\text{ lm/W}. The absolute convention gives no assertion of 100% optical efficiency. Use the measured lumens with the matching utilization data and apply only relevant light-loss factors.

Electronic Files (IES LM-63 / EULUMDAT) and Goniophotometry

ANSI/IES LM-63 defines an electronic format for photometric distribution and associated data. The file can contain product and test identifiers, tilt information, a candela multiplier, the coordinate type, luminous opening dimensions, input watts, and vertical and horizontal angle lists followed by the candela array. Read the multiplier and documented symmetry before interpreting raw intensities. Check that the file represents the actual wattage, optics and setting you intend to model.

The LM-63 photometric type field uses 1 for Type C, 2 for Type B, and 3 for Type A. Type C is commonly used for architectural and roadway products. Type B is common in reports for aimed floodlighting. Read the actual coordinate conventions before rotating an asymmetric optic. EULUMDAT, commonly exchanged in an LDT file, is a distinct format.

Far-field intensity describes the distribution when the luminaire is sufficiently distant relative to its size and optical geometry. A long linear grazer near a wall may need near-field data or a validated model. Always consider the measurement method and the task distance before using a point-source approximation.

References: IES spacing criterion, IES LM-63 format, Lighting Analysts LM-63 documentation, IES CU and utilance definitions, and IES near-field modeling.

Loading diagram...
Relative Photometry vs. LM-79 Absolute Photometry in Lumen-Method Calculations
Test Your Knowledge

A surface-mounted linear luminaire’s luminous plane is 10.5 ft above the floor and the desk workplane is at 2.5 ft. The spacing criterion across the rows is 1.30. What is the preliminary row-to-row spacing check?

A

14.30 ft

B

11.05 ft

C

10.40 ft

D

8.00 ft

Test Your Knowledge

An absolute test report gives a complete fixture’s delivered lumens. Which input should you pair with utilization data explicitly based on delivered luminaire lumens?

A

The measured delivered lumens.

B

The bare-source lumens multiplied by an additional fixture loss.

C

Input power multiplied by wall reflectance.

D

Peak candela treated as total lumens.