5.2 LED Testing and Lifetime Standards (LM-79, LM-80, TM-21)
Key Takeaways
ANSI/IES LM-79-24 measures optical and electrical performance of solid-state lighting products under stated test conditions.
LM-80-21 records maintenance of light-output characteristics for LED sources such as packages, arrays and modules. TM-21-21 projects source flux maintenance from applicable data.
Compare in-situ component temperature and operating current against the data supporting a projection. Report a compliant bound when the computed time exceeds the method’s horizon.
LM-84 and TM-28 address maintenance testing and projection at the lamp or luminaire level. A flux-maintenance metric is distinct from risk of sudden system failure.
Ask what was tested
The name of a test method matters because it tells you what the number represents. For a substitution, ask for evidence from the exact luminaire configuration and operating mode. Then distinguish a measurement of its initial output from a projection based on the light sources inside it.
| Method | Specimen or inputs | What you can learn |
|---|---|---|
| ANSI/IES LM-79-24 | A solid-state lighting product | Measured optical and electrical performance including total flux, input power, efficacy, distribution, and color quantities under the reported conditions. |
| ANSI/IES LM-80-21 | LED packages, arrays, or modules | Measured changes in light output and color characteristics over operating time under controlled conditions. |
| ANSI/IES LM-98-24 | Components in an operating lamp or luminaire | In-situ temperatures of identified components under the method’s specified test conditions. |
| ANSI/IES TM-21-21 | Applicable LM-80 source data | Projection of the source’s flux maintenance, with conditions and limits on what can be reported. |
| ANSI/IES LM-84-20+E1 and TM-28-20 | LED lamp or luminaire data. LM-84 also addresses light engines. | LM-84 measures maintenance over time. TM-28 projects lamp or luminaire luminous flux maintenance from product test data under its direct or combined method. |
Initial output and distribution
A complete LED luminaire measured using absolute photometry reports the flux leaving the assembled product. For a design, enter that flux and the matching distribution. A goniophotometer measures output by direction, while an integrating-sphere system can measure total flux. The test report and distribution file should identify the tested model and configuration. Changing the board, diffuser, or drive current can make a previously measured report unsuitable.
In a relative photometric description of a replaceable-lamp system, separate lamp output and luminaire optical performance may be part of the calculation. An absolute complete-luminaire result already incorporates the optical behavior of the tested fixture. Applying an additional fixture-efficiency multiplier would count the losses twice.
Source maintenance and operating conditions
A source report alone cannot establish how the same LED component will perform inside every luminaire. Temperature and drive current affect maintenance. Check the installed product’s operating current and measured in-situ temperature at the specified measurement point. Verify the exact source against the LM-80 conditions and use the proper interpolation or projection procedure. A source flux threshold also does not establish a chromaticity tolerance. If the project specifies color maintenance, evaluate that separately.
refers to the elapsed operating time when the stated source or product is projected or measured to retain 70% of its initial luminous flux under the stated conditions. Review what equipment and method the cited number covers. A luminaire may lose light gradually, change color, have intermittent operation, or stop operating because the driver or another component fails. The time to a flux threshold does not estimate all those failure modes or define the warranty.
Worked reporting limit
Suppose a compliant component data set contains 25 specimens tested for 8,000 hours. For an in-range operating point, the example supplies the fitted normalized flux relation , with and . Solving gives:
This equation merely evaluates the supplied fit. The DesignLights Consortium SSL V6.0 criteria apply a projection limit of six times test duration for at least 20 samples, and 5.5 times for 10 through 19 samples. For the 25-sample case, the horizon is . If the applicable report confirms the fit and sample conditions, express the result as , rather than offering the computed 86,100 h as an approved projection. With 15 samples and the same test duration and assumptions, the horizon would be .
Submittal comparison
If an owner’s specification calls for a supported 50,000-hour result, check the projection horizon first. A result bounded only beyond 48,000 hours does not show that the criterion is satisfied. Ask whether longer suitable component testing or a product-level test and projection can support the required result. The approved method and reporting evidence can matter as much as the nominal hours on a cut sheet.
For a 50,000-hour project criterion, a six-times horizon calls for at least 8,334 hours of test data if the duration is reported in whole hours. A 5.5-times horizon calls for at least 9,091 hours. In both cases these figures only establish test duration sufficient for the reporting horizon. The source must still retain enough projected flux to meet the criterion, and the applicable test conditions must support the product’s current and component temperature.
Ask a supplier to identify the exact emitter and drive condition for each proposed driver option. A dimmer setting or a revised heat sink can change how a unit runs. Compare the cited evidence with the configuration the owner will actually receive, including optics and driver access, and record any separate warranty terms in the submittal evaluation.
References: IES current standards, IES TM-21 calculator and method references, DLC SSL V6.0 and LUNA V2.0 criteria, §27.3, and DOE LED luminaire lifetime recommendations.
A project uses the DLC SSL V6.0 component projection rules. A cut sheet reports an L70 of 110,000 hours from a qualifying group of 25 LED packages tested for 10,000 hours. Which review is correct?
The sample size permits the unrestricted 110,000-hour projection.
The reporting horizon is 60,000 hours. A calculation beyond it can support a bound over 60,000 hours rather than the claimed specific time.
LM-80 must first measure driver capacitors in the complete fixture.
Report the claim as an LM-79 time to half of the samples failing.
A designer has delivered lumens and the measured distribution from absolute photometry of a complete LED fixture. Why should the designer avoid multiplying those lumens by a separate lens-efficiency factor?
The test measured only the package before installation.
Every tested LED fixture has zero optical loss.
The measured total already represents light leaving the assembled product.
The distribution measures temperature instead of emitted light.
An LED fixture’s component report gives an L70 projection. What can this value establish when properly derived under the stated conditions?
The time at which the source is projected to reach 70% of its initial luminous flux.
The scheduled replacement date of the complete fixture and driver.
The point when 70% of the LED packages fail suddenly.
The initial driver conversion efficiency.