11.4 Exterior, Site, Parking, and Roadway Lighting
Key Takeaways
IES RP-8 addresses roadway and parking facility applications. Use the applicable edition and agency requirements.
Roadway luminance depends on pavement and driver geometry. Compute each ratio on its specified grid or observation basis.
Check pedestrian and driver visibility, obstructions and daylight transitions in parking facilities.
Installed light at the boundary and reflected sky glow depend on the whole layout, including aiming and schedule.
Roadway: pavement, targets and driver views
A local agency is evaluating lighting for a collector street. Identify roadway classification, traffic and pedestrian conflicts, and the design method and criteria specified by the agency. The current IES title Lighting Roadway and Parking Facilities, RP-8, covers both types of application. RP-20 is a historical parking reference. Use the project’s required edition and any controlling agency criteria.
Pavement luminance describes light leaving the pavement toward the observer. It depends on road surface reflectance and the directions of incident and viewed light. Two pavements at the same horizontal illuminance can have different luminance in a driver’s view. Visibility also depends on the luminance contrast of the object, whether it is darker or brighter than its background, and on glare. Use the specified design method and grid. An intersection or crossing can call for checking pedestrians and vertical planes in addition to the pavement.
For a luminance-based check, compare average luminance and the required measures of uniformity. For example, average-to-minimum and maximum-to-minimum express different comparisons. If a project specifies a longitudinal check, use the designated samples along the lane. Computing that ratio with a minimum taken from an unrelated lane or grid can give a different result. Veiling luminance represents the contrast-reducing effect of disability glare under the model. Check the ratio and observer positions specified by the project.
At a highway interchange, compare candidate distributions from the proposed mounting heights and locations. A high-mast system may serve a large, complex layout. Verify that its measured distribution covers ramps and conflict points and controls glare in the specified driver views. Consider access for maintenance, aiming and effects beyond the road. The mounting style and optic label cannot substitute for these checks.
Parking: navigation, faces and the day-to-night entrance
For a surface lot, identify aisles, pedestrian crossings, curbs, stairs and doors. Check horizontal lighting where people walk and drive. Where the project includes identifying faces or monitoring entry, verify relevant vertical illumination and camera conditions. Vehicles and columns can block light, so inspect the occupied lot as well as the empty photometric model.
A covered garage receives daylight at its entrance but little near the center. Study the approach, ramp and first interior section during bright daylight and at night. A separate entrance control zone can help manage the transition when justified by the actual geometry and adopted criteria. Avoid assigning a universal daylight or nighttime entrance level. Check views, approaching vehicles and pedestrian routes, then test the control change and any required emergency response.
Site: the property line and actual operating conditions
A neighborhood retail site borders homes. Mark the property line, openings and late-night route before comparing equipment. Look at installed aiming and the specific photometry, including selected shields. A low backlight grade can aid initial selection. Calculate the actual boundary light and verify the applicable ordinance or project requirement. Direct uplight and reflected light can both contribute to sky glow. A low uplight rating does not establish the outdoor effect by itself.
Use light for the occupied routes and tasks, direct it where needed and set the operating schedule. Check available spectrum options and actual site requirements. Compare the post-closing scene, any presence response and the restoration sequence, including legitimate late-night access. Measure the relevant conditions after installation and correct aiming or controls as needed.
For a walking route through the site, compare a shielded low-mounted system and a taller pole layout using the specified views and measured distributions. Check whether a low-mounted source itself is visible from a seated approach or becomes hidden by landscaping, and whether the taller layout lights areas outside the path. Arrange the final aiming check after the pavement and adjacent surfaces are in place.
Worked ratio check
A hypothetical project calls for average pavement luminance of at least 0.80 cd/m², an overall average-to-minimum ratio no greater than 3.5, a specified lane maximum-to-minimum ratio no greater than 5, and a veiling-luminance-to-average ratio no greater than 0.30. These are project inputs. Its reported overall average and minimum are 0.90 and 0.25 cd/m², the specified lane maximum and minimum are 1.15 and 0.28 cd/m², and maximum veiling luminance is 0.36 cd/m².
The average passes. The overall ratio fails. The lane ratio passes. The glare ratio fails. Review the locations of the low pavement readings and the contribution to glare in the relevant driver view. Try changes to distribution or layout and calculate all criteria again. An adjustment that resolves one ratio can change the others.
References: IES current roadway and parking practice, IES current and deprecated editions, FHWA Lighting Handbook, IES TM-15 outdoor classification, and DarkSky and IES responsible outdoor lighting principles.
A roadway project limits average-to-minimum, lane maximum-to-minimum and veiling-luminance-to-average ratios to 3.5, 5.0 and 0.30. Average luminance is 1.00 and overall minimum is 0.30 cd/m². The designated lane has maximum 1.35 and minimum 0.30 cd/m². Veiling luminance is 0.45 cd/m². Which check fails?
All three ratios fail.
Only the veiling-luminance ratio fails.
Only the lane maximum-to-minimum ratio fails.
All three ratios pass.
Drivers entering a covered garage from bright daylight report a sharp change in visibility. Pedestrians also report shadows near parked vehicles. Which review is most relevant?
Check a single annual average of connected lighting watts.
Increase exterior-only uplight at the site boundary.
Verify the merchandise color of a nearby retail shop.
Evaluate the entrance transition by day and night and verify pedestrian routes, vertical views and obstructions in the parking area.
A parking site borders homes. The proposed fixtures have low backlight. What additional evidence best demonstrates that the planned installation addresses the boundary criterion?
The manufacturer’s nominal CCT alone.
The published backlight rating on an alternate optic.
Boundary calculations using the selected fixture, shield and installed aim, followed by field verification in relevant operating scenes.
The average horizontal light level in the center of the lot only.