3.1 Radiation Protection, ICRP/Euratom Principles & Pregnancy Imaging

Key Takeaways

  • Justification and optimisation govern patient medical exposure. Occupational and public limits apply to distinct exposure categories.

  • Diagnostic reference levels compare typical exposures for groups of similar examinations. Repeated high institutional values support review of technique and image quality.

  • Gray measures absorbed dose. Sievert is used for equivalent and effective dose, quantities with different purposes.

  • Tissue reactions have effect-specific approximate thresholds. Stochastic risk is managed using a model in which probability rises with dose.

  • Assess clinical probability and available imaging in suspected pulmonary embolism in pregnancy. Negative leg ultrasound alone cannot exclude embolism.

Last updated: November 2026

Justification, optimisation and dose limits

European radiation protection draws on the International Commission on Radiological Protection (ICRP) and the European Union Basic Safety Standards in Council Directive 2013/59/Euratom, implemented through national law. The three principles are justification, optimisation and dose limitation. They answer different questions about the same examination.

  • Justification asks whether the expected benefit exceeds the potential detriment, given the patient's clinical question and reasonable alternatives. The practitioner and referrer take part in justification as specified in national law. Check prior imaging before repeating an exposure.
  • Optimisation requires exposure as low as reasonably achievable while obtaining the information needed. Choose coverage, phases and settings relevant to the indication. A low-dose image that misses the finding and must be repeated defeats the purpose.
  • Dose limitation applies to regulated occupational and public exposures. It does not impose an annual radiation allowance on an individual patient's justified medical exposures. A patient who has reached a high cumulative dose may still need an urgent study if the result will guide care.

The Directive distinguishes the referrer, authorised to refer an individual for exposure, from the practitioner, who has clinical responsibility for the exposure and participates in justification and optimisation. The medical physics expert advises on dosimetry, optimisation, equipment testing and significant unintended exposures at a level appropriate to the practice. Exposure information belongs in the procedure report under Article 58. Article 63 requires systems to learn from unintended exposures and mechanisms to notify significant events under national requirements.

Compare the right quantities

Absorbed dose is energy deposited per unit mass, measured in gray (Gy). Equivalent dose applies a radiation weighting to the dose in a tissue and is expressed in sievert (Sv). Effective dose also applies tissue weighting. It is a reference protection quantity for comparative use and does not give an individual patient's organ dose or personal cancer risk. CT dose index, dose–length product and air kerma–area product describe aspects of examination output. Select the indicator appropriate to the modality and question. A fetal absorbed dose estimate uses the examination details and anatomy rather than simply re-labelling the CT scanner index.

Diagnostic reference levels (DRLs) help departments recognise techniques needing review. Under Commission Recommendation (Euratom) 2026/403, the usual national DRL is the 75th percentile of the distribution of facility typical values, commonly medians for comparable examinations. A single high reading may be justified by the task and patient size. Repeated high typical values for comparable patients and protocols call for investigation. Check patient groups, equipment, coverage and clinical indication, and confirm that image quality remains adequate after a change. The DRL guides optimisation and does not set an individual limit.

Biological effects

EffectDose relationshipExamples
Stochastic effectProtection models assume that the probability increases with dose without a threshold. This is a model for radiation protection rather than a precise prediction at very low dose.Cancer and heritable effects in the protection framework.
Tissue reactionUsually described by an approximate threshold for a defined effect and incidence. Above it, frequency and severity generally rise with dose. Exposure duration and tissue sensitivity matter.Skin erythema, epilation and lens opacity.

For an exam comparison, early transient skin erythema may occur after a local absorbed dose of about 2 Gy, and temporary epilation after about 3 Gy. These are approximate tissue-response values. A displayed fluoroscopy reference air kerma is not the local skin dose. ICRP Publication 118 estimated a threshold of approximately 0.5 Gy for vision-impairing lens injury, with uncertainty. The statutory equivalent-dose limit for workers is a different quantity, discussed in the occupational section.

Pregnancy and special populations

When pregnancy is possible and relevant, ask about it and follow the local pathway. Article 62 calls for particular attention to justification, urgency and optimisation when pregnancy cannot be ruled out, especially for examinations of the abdomen or pelvis. Ultrasound or non-contrast MRI can answer many questions. If an ionising examination is indicated, select a protocol that preserves the required information and limits unnecessary coverage or acquisitions. Do not use a universal menstrual-date rule to decide whether urgent imaging can proceed. In children, adapt exposure to the child's size and the clinical question and check that repetitions are necessary.

For an inadvertently exposed pregnancy, establish whether the uterus was in the primary beam and involve medical physics when an individual dose estimate could affect counselling. Fetal effects depend on developmental stage and absorbed dose. ICRP advises that a fetal dose below 100 mGy does not justify termination on radiological grounds alone. This is a counselling statement. It does not establish a universal threshold for every effect or remove the need for justification. An optimised chest examination normally gives much less fetal exposure than a scan in which the uterus is directly irradiated.

Worked clinical distinction

In a stable pregnant patient with suspected pulmonary embolism, the 2025 European Society of Cardiology (ESC) guideline uses clinical assessment and D-dimer in a structured pathway, with venous ultrasound when indicated. A negative venous scan alone does not exclude pulmonary embolism. When chest imaging is still indicated after negative or inconclusive venous ultrasound, the ESC Figure 10 pathway uses CT pulmonary angiography (CTPA) if available. Its fallback is chest radiography and a perfusion lung scan when CTPA is unavailable. Compare maternal and fetal exposure, diagnostic yield and access in the local pathway. A normal chest radiograph alone does not decide whether the patient needs chest imaging or exclude embolism. With haemodynamic instability, follow the urgent assessment and resuscitation pathway rather than using a routine stable-patient algorithm.

See 2013/59/Euratom, 2026/403 DRL recommendation, ICRP 118, ICRP 117, and ESC 2025 pregnancy guidance, section 11.4 and Figure 10.

Test Your Knowledge

Under ICRP Publication 103 and Council Directive 2013/59/Euratom, which regulatory tool is used to support optimisation of patient doses during routine CT examinations?

A

An individual annual effective dose limit of 20 mSv for patients

B

Diagnostic reference levels, normally set nationally at the 75th percentile of comparable facility typical values

C

An individual annual effective dose limit of 1 mSv for outpatient diagnostic imaging

D

Mandatory pregnancy testing for all patients prior to thoracic CT

Test Your Knowledge

A stable pregnant patient with suspected pulmonary embolism still requires chest imaging after clinical assessment and negative venous ultrasound. In the 2025 ESC pregnancy pathway, CT pulmonary angiography is available and there is no contraindication. What is the next imaging test?

A

Pregnancy-optimised CT pulmonary angiography

B

Routine dual-phase chest CT plus CT venography in every case

C

Gadolinium-enhanced MR pulmonary angiography

D

Deferred chest imaging until postpartum