13.5 Interventional Work-up, Vascular Access & Safety

Key Takeaways

  • Define the treatment goal, alternatives, relevant test results and recovery plan before selecting an access site.

  • Use a checklist and a team pause to confirm identity, target, equipment, patient risks and rescue resources.

  • Use ultrasound and other applicable imaging to check access anatomy and verify where needles, wires and catheters are before proceeding.

  • Monitor sedation, perfusion, bleeding and radiation appropriately. Technical success requires clinical review and clear handover.

Last updated: November 2026

Define the Goal and Anticipate Failure

Start with the indication and expected benefit. A drainage procedure may target sepsis, decompression or sampling; a vascular procedure may target bleeding, restore flow or obtain access. Explain alternatives and risks, including the risk of no procedure. Check relevant prior imaging in the position and phase closest to the proposed treatment and think through a backup route and escalation plan. Discuss material risks, capacity and consent according to local practice. The urgency of source control or haemostasis may change how long optimisation can safely take.

Use the CIRSE safety checklist or local equivalent before starting, with the patient, team and essential equipment ready. Confirm identity, indication, site, allergies and prior contrast reactions, renal function where relevant, bleeding and antithrombotic risk, infection and any indicated antimicrobial prophylaxis. Use the procedure-specific protocol for when laboratory tests and medication changes are needed. A superficial aspiration and a new transhepatic puncture pose different risks. If delaying treatment or stopping an antithrombotic also poses harm, coordinate the decision with the relevant team. Neither a universal INR threshold nor a blanket instruction to stop all anticoagulants is appropriate for every procedure.

Plan local anaesthesia, moderate sedation or anaesthesia support according to the expected pain, duration, patient physiology and airway risk. The team needs trained personnel, appropriate observation of ventilation, oxygenation and circulation, access to equipment and rescue capability. An unexpected drop in ventilation or oxygenation requires immediate attention even when the technical step is incomplete. CIRSE Clinical Practice Manual, CIRSE checklist and ACR–SIR sedation practice parameter.

Verify the Route Through Each Exchange

Use ultrasound-guided access when feasible to assess vessel patency and nearby structures and track the needle. The artery and vein may overlap in a given position. When using common femoral arterial access, assess the relationship to the femoral head, inguinal ligament and bifurcation. A high puncture can make compression ineffective and permit retroperitoneal bleeding. A low puncture can involve a smaller branch or a region where artery and vein overlap. Radial or other access may better fit some targets and anatomy. Use the appropriate sterile preparation and confirm needle and wire position before dilation. In an over-the-wire access sequence, the guidewire maintains the route while a sheath or catheter is exchanged. If position or resistance is unexpected, stop and clarify rather than dilating blindly.

Imaging decisionApplication
UltrasoundDistinguishes adjacent vessels and can reveal thrombus or calcification that changes the route. It does not show every deep part of a wire course.
Fluoroscopy and subtraction angiographyVerify device course and display vascular filling. Motion between the mask and contrast images can mimic abnormality or obscure a branch. Compare unsubtracted images or repeat a targeted acquisition when needed.
CT or combined guidanceMaps deep structures, fluid, air and cross-sectional routes. Use a limited range and phases appropriate to the task.
Completion reviewConfirm the device or treatment endpoint, required perfusion or drainage, and complications such as extravasation or an access-site problem.

For an access-site example, hypotension with new flank or back pain after a high femoral puncture can reflect retroperitoneal bleeding even if the visible groin is not enlarged. Escalate promptly and use the safest available evaluation and source-control route. For a stable patient with a pulsatile groin lump, duplex can assess the puncture artery and a possible pseudoaneurysm or fistula.

Close the Procedure and Hand Over

Optimise fluoroscopy with collimation, appropriate pulse rate, last-image hold and imaging geometry. Prolonged procedures can concentrate dose in a single skin region. Record the system-reported dose indicators and apply the local follow-up protocol when trigger levels are reached. Dose–area product does not locate the peak skin exposure. Review shielding and staff position separately from the patient dose strategy.

At the end of the procedure, confirm access-site haemostasis and observe the patient according to the type of procedure and sedation. Communicate technical success or its limits, how and when medicines are resumed, the observation or drain plan and what changes warrant contact. New pain, fever, changing haemodynamics or unexpectedly poor organ or catheter function needs clinical assessment even if the final images looked satisfactory. CIRSE Clinical Practice Manual.

Test Your Knowledge

Before an urgent new biliary puncture, the patient is taking an anticoagulant for a recent thrombotic indication. What is the best preparation principle?

A

Hold anticoagulation for the same interval for every interventional procedure.

B

Ignore bleeding risk because the indication is urgent.

C

Assess procedure and patient bleeding risk, thrombotic risk and harm of delay, then agree the plan with the treating team.

D

Use the access-sheath diameter as the sole determinant.

Test Your Knowledge

During ultrasound-guided vascular access, the wire course is uncertain and the dilator meets unexpected resistance. What is the safest next action?

A

Advance immediately while the wire provides some resistance.

B

Stop and confirm access and wire position with appropriate imaging before progressing.

C

Proceed if the puncture was in roughly the right region.

D

Use the last dose–area product value to infer wire location.

Sections you finish are checked off in the contents.