15.2 Reporting, Quality Improvement and AI Governance
Key Takeaways
Match communication to the risk and urgency. Use an approved alert and a verified route to a responsible team, document the contact and escalate if required.
A useful report answers the clinical question, records important limits, compares relevant prior imaging and states a supported next step when indicated.
Audit practice against a defined standard, implement change and repeat measurement. Address risks to the patient separately from educational case review.
EU device software classification is based on intended purpose and potential impact. The current EU AI Act has a phased application calendar.
Assess a model for the intended clinical workflow, subgroup performance and failure modes. Review relevant changes and monitor outcomes after deployment.
Deliver the Result to a Team That Can Act
Separate a critical finding associated with immediate or acute harm from an important unexpected finding that can use a less urgent pathway. An imaging finding suggesting acute spinal cord compression or free intraperitoneal gas in an unwell patient may need rapid action. A suspected malignancy on unrelated imaging also needs an agreed follow-up route, with timing determined by the context and local standard. For incidental pulmonary nodules, verify the applicable population and use morphology, size and clinical risk. The Fleischner incidental guideline allows some small solid nodules in low-risk adults to be left without routine follow-up. Screening and oncology pathways have distinct rules.
The UK RCR recommendations use a critical alert on the reporting platform, with a direct verbal route when needed. Use the local pathway for the right urgency, including a backup if the original referrer cannot respond. Confirm that the intended clinical team receives and understands the finding and has a plan. Read-back is one way to check a high-risk handover when required or helpful. Document the patient, finding, time, recipient and next action or unsuccessful contact and escalation. A teaching example is new free gas with an unacknowledged digital alert. Contact an appropriate on-call clinical team via the urgent pathway, and track the alert and response.
| Part of a report | What it contributes |
|---|---|
| Indication and technique | The question, examination and any important limitation that changes interpretation. |
| Comparison and findings | Identify relevant comparison dates and localise and measure findings when appropriate. State important positive and negative findings in context. |
| Impression and next step | Give a diagnosis or ranked differential, meaningful uncertainty and urgency, and a supported next step where indicated. |
| Addendum and notification | Keep the report history. If a significant change could alter care, use the appropriate notification pathway and document it. |
In a multidisciplinary meeting, present the relevant images, clarify the management question and document important changes to a clinical interpretation. For example, if review contests the feasibility of resection because of a vessel relationship, show the critical planes and record the updated interpretation and uncertainty. Discuss results with patients within the agreed care pathway, using respectful language and addressing uncertainty and next steps. Patients should understand what to expect and whom to contact. Confidentiality and consent obligations continue in remote reporting and at case conferences.
Audit, Correct and Learn
Start a clinical audit by choosing an explicit standard and defining a denominator, exclusions, numerator and data source. Measure current practice, identify reasons for any gap, make a change and remeasure. For example, a department can check the proportion of critical alerts acknowledged in its specified window. State who will review unacknowledged cases and when the revised escalation process will be measured. The initial measurement is part of an audit. Remeasurement shows whether the change worked. Audit asks how practice compares with a standard, while research asks a question designed to produce new knowledge. Determine the oversight requirements for the specific activity.
When a discrepancy comes to light, first consider risk to the patient. Take needed corrective action, amend the report and communicate it through the appropriate clinical pathway. Follow local incident and candour requirements. Then consider the case for de-identified learning. An RCR Radiology Events and Learning Meeting is formative and kept separate from investigation, performance management and individual candour processes. Review workload, protocol, the images and information available at the time, and other system factors. A later diagnosis can make a subtle sign seem more obvious in hindsight. Double reading has a defined role in some programmes and a service should specify if readings are independent and how disagreement is resolved.
Euratom Directive 2013/59, Articles 55, 57 and 58, requires medical exposures to be justified in advance, involves the referrer and practitioner as specified by Member States, places clinical responsibility with the practitioner and requires referral guidance and clinical audit under national procedures. Use the locally applicable guidance. For a department choosing teleradiology or an AI product, include oversight, workforce and interpretation coverage, equipment compatibility, support, total cost, reporting latency and the failure pathway. Test the workflow before accepting it.
Evaluate an AI System in its Intended Workflow
For EU medical device software, the MDR's Annex VIII Rule 11 generally assigns software providing information used for diagnostic or therapeutic decisions to class IIa, rising to IIb or III according to the consequences specified by the rule. Significant distinctions include serious health deterioration or surgical intervention in IIb, and death or irreversible deterioration in III. Classification depends on the intended purpose. A generic archive's role and a diagnostic decision-support tool have different regulatory questions. CE marking indicates the applicable conformity procedures were followed. Evaluate the intended use and the evidence behind the claimed performance.
The EU AI Act entered into force on 1 August 2024. The general application date was 2 August 2026, with provisions phased in. An AI system is high-risk under Article 6(1) when it is a product, or a safety component of a product, covered by Annex I legislation and that product is required to undergo third-party conformity assessment. After the 2026 amendment, the provisions linked to this classification apply from 2 August 2028. Applicable device-law obligations continue according to their own timetable.
Before deployment, ask whether the independent test set and reference standard represent likely patients, equipment, image protocols and disease spectrum. In a local evaluation, compare performance with and without the tool for the actual task, record missing outputs and look for subgroup differences. Examples include lower sensitivity on an underrepresented scanner and false alarms that make an urgent-reading queue less usable. Check latency and route failed cases for ordinary clinical review.
After deployment, assign responsibility for monitoring, escalation and reassessment after significant changes. Data drift can occur when referral patterns or reconstruction methods change. Error patterns and outcomes may also change because the disease definition or model version changed. Automation bias can lead a reader to accept a false finding or overlook a condition the model failed to flag. Design supervision and training so the reader can see the underlying images, understand the tool's limits and override its result. CE marking and local performance answer different questions.
RCR reporting standards · RCR critical alerts recommendations · Fleischner incidental nodule guideline · HQIP clinical audit · RCR 2026 case learning standards · EU Euratom Directive · EU MDR Annex VIII · MDCG 2025 guidance on software classification · EU AI Act consolidated after the July 2026 amendment · Five-society clinical AI implementation guidance
A CT shows an urgent unsuspected pneumoperitoneum. The digital critical alert remains unacknowledged and the referring clinician cannot be reached. What is the appropriate next action?
Wait for the report to be opened on routine review
Send the report to an unrelated ward
Assume the referrer received it since the alert was generated
Use the local escalation route to contact the responsible on-call team, verify receipt and document the exchange
Which statements correctly describe clinical audit and imaging AI governance? Select all that apply.
Select all that apply
Audit compares practice with an explicit standard and measures again after a change to evaluate improvement
CE marking guarantees the model will reproduce published performance at every hospital
Automation bias can lead a reader to accept a false software result despite contrary image findings
An educational radiology learning meeting is separate from correcting the patient’s report and appropriate clinical notification