11.1 Paediatric Chest, Airway & Neonatal Respiratory Emergencies

Key Takeaways

  • Read the neonatal film alongside gestational age, onset, ventilation and treatment. Low-volume diffuse granular opacity supports surfactant-deficient RDS, while fissural fluid favours transient tachypnoea and asymmetric coarse opacities favour meconium aspiration.

  • A child with drooling, dysphagia and a tripod position may have epiglottitis. Keep the child comfortable, alert the experienced airway team and defer examination or imaging that could destabilise the airway.

  • Normal radiographs cannot exclude foreign body aspiration. A convincing history with persistent focal signs warrants specialist bronchoscopy assessment. Stable equivocal cases can be considered for low-dose noncontrast CT.

  • Ultrasound can characterise a clinically important pleural effusion. In suspected congenital lung malformation, map cysts, any systemic feeding artery and venous drainage before an operation.

  • The smooth thymic sail is normal. The spinnaker sail sign is the thymus lifted by mediastinal air.

Last updated: November 2026

Reading the Neonatal Chest

Before reading the opacity, check gestational age, time since birth, delivery history, infection risk and respiratory support. Assess inflation alongside the distribution of lung opacity, tubes and air leak. Positive-pressure support and surfactant treatment can change the classic appearances.

ConditionTypical contextDiagnostic clues on chest radiography
Respiratory distress syndrome (RDS)Preterm infant with distress soon after birthLow volumes, diffuse fine granular or ground-glass opacity and air bronchograms. Severe cases may obscure the cardiac outlines.
Transient tachypnoea of the newborn (TTN)Term or near-term infant, often after caesarean deliveryPerihilar streaking, fluid in a fissure or small pleural effusions and normal to mildly increased lung volume. Findings usually improve over 48–72 hours.
Meconium aspiration syndromeTerm or post-term infant with meconium-stained fluidCoarse, patchy, often asymmetric opacities with air trapping, sometimes alternating with atelectasis. Check for air leak.
Neonatal pneumoniaInfection risk or systemic illnessPatchy or focal opacity, consolidation or pleural fluid. Diffuse appearances can overlap with RDS.

In RDS, surfactant deficiency promotes alveolar collapse. Antenatal corticosteroids in appropriate pregnancies reduce risk, and exogenous surfactant and respiratory support change subsequent imaging. With clinical infection risk, a film resembling RDS cannot rule out pneumonia. Lung ultrasound can provide bedside information in trained hands and complements the radiograph and clinical assessment.

Air Leak in the Neonate

Pulmonary interstitial emphysema (PIE) can develop in a ventilated preterm infant. Air dissects along the pulmonary interstitium, producing coarse linear or small cyst-like lucencies, sometimes predominantly in one lung. Look separately for pleural air. Chronic lung disease of prematurity can show coarse or cyst-like changes later in the clinical course.

In a supine infant, pleural air can collect anteriorly, medially or at the base. A very lucent hemithorax or a deep costophrenic sulcus can be the clue to pneumothorax. With sudden cardiorespiratory deterioration, alert the neonatal team immediately. Suspected tension physiology requires emergency action without waiting for radiographs. In pneumomediastinum, air outlining and lifting the thymus creates the spinnaker sail sign.

Worked case. A 28-week infant with initially small, granular lungs is receiving positive-pressure ventilation. On day three, oxygen needs rise and branching lucencies appear inside one lung. This distribution suggests PIE. Check for a separate pleural line or deep sulcus and communicate both the interstitial air leak and any suspected pneumothorax.

Paediatric Stridor and Suspected Aspiration

In typical croup, barking cough, hoarseness and inspiratory stridor establish a clinical diagnosis. Routine radiographs are unnecessary. When a radiograph has been obtained in a stable child with diagnostic uncertainty, smooth subglottic tapering can produce the steeple sign. Severe or deteriorating obstruction needs experienced airway support.

Consider epiglottitis in a febrile child with abrupt dysphagia, drooling, muffled voice and a preference for sitting forward. Hib vaccination has changed its frequency. An enlarged epiglottis may produce a thumb sign on a lateral image already available.

Warning

In a child with a threatened airway, allow the position of comfort, minimise distress and immediately alert experienced paediatric airway staff. Defer transport for imaging and avoid a forced oropharyngeal examination until the airway can be managed safely.

A toxic child with rapidly progressive stridor and thick secretions may have bacterial tracheitis. The airway team may use endoscopy to identify and clear obstructing material. Fever, neck pain, torticollis and dysphagia can suggest retropharyngeal infection. After airway assessment, contrast-enhanced CT helps map a suspected deep-space infection, including extension towards the mediastinum. Prevertebral soft-tissue width on a lateral radiograph is sensitive to neck position and does not establish an abscess.

Foreign body aspiration is suggested by a choking episode followed by persistent cough, focal wheeze or reduced air entry. A radiolucent object may leave a normal film. Look for unilateral air trapping, collapse or consolidation. When a child is stable, radiographs are a common starting point. Strong ongoing clinical suspicion warrants specialist assessment for bronchoscopy, even with a normal film. In a stable equivocal case with negative initial radiographs, current ACR criteria favour low-dose noncontrast chest CT as the next imaging study when imaging is needed. Decubitus views are usually inappropriate in that pathway.

Chronic inspiratory stridor in infancy can reflect laryngomalacia, a dynamic supraglottic problem assessed by flexible laryngoscopy. Persistent or recurrent fixed subglottic narrowing suggests subglottic stenosis, especially after intubation, and warrants specialist assessment.

Pulmonary Infection, Congenital Lesions and Chronic Airways Disease

Imaging is usually unnecessary for straightforward community-acquired pneumonia. When a film is indicated, focal air-space consolidation, perihilar opacity and atelectasis describe patterns with overlapping causes. Rounded consolidation in a febrile child may represent round pneumonia, often solitary and posterior. Atypical features, persistent symptoms or persistent focal opacity prompt reassessment for another cause.

Use pleural ultrasound for the size and complexity of a moderate or large parapneumonic effusion. Septations guide procedural planning. The decision to drain takes account of fluid size, respiratory compromise and evidence of pus. Selected severe or complicated cases need CT to assess lung necrosis, an abscess or a suspected bronchopleural fistula. A persistent air leak or hydropneumothorax raises suspicion of a fistula in the appropriate setting. In US IDSA/PIDS guidance for children older than three months, drainage is recommended for large or purulent collections, or a moderate effusion with respiratory distress.

For a prenatally detected lung lesion, compare the postnatal findings with fetal imaging and tailor further imaging to symptoms and the surgical question. Congenital pulmonary airway malformation can form a cluster of cysts. A systemic feeding artery raises concern for sequestration or a hybrid lesion. Contrast-enhanced cross-sectional imaging maps that vessel and the venous drainage. Congenital lobar overinflation enlarges a lobe, with stretched vascular markings and possible compression of adjacent lung. Visible markings within the expanded lobe help distinguish it from a pleural air collection, which may show a pleural line.

In cystic fibrosis, look for bronchiectasis, bronchial wall thickening, mucus plugging and air trapping. PRAGMA-CF is a structured CT research measure of the extent of airways disease. European CF guidance individualises CT use and discourages routine follow-up CT in preschool children. If CT is indicated, use an optimised paediatric protocol. MRI is an option in experienced centres for selected follow-up questions. Studies of eligible children receiving CFTR modulators have shown improvement in lung function or MRI findings. In asthma, use imaging when the presentation suggests a complication or an alternative such as pneumonia, pneumothorax or foreign body.

The normal infant thymus may have a triangular sail configuration with a straight inferior edge, or a wavy lateral margin where it meets the ribs. The expected smooth contour and lack of airway compression help distinguish it from a mass.

ESPR paediatric pulmonary imaging · European RDS consensus · ERC newborn resuscitation · Supine neonatal pneumothorax · Thymic spinnaker sail case · Thymus anatomy and radiographic variants · Acute paediatric airway pathway · ESR deep-neck infections · ACR aspirated foreign body · Paediatric inhaled foreign body pathway · Paediatric laryngomalacia consensus · Post-intubation stenosis cohort · Round pneumonia cohort · IDSA/PIDS 2026 pneumonia update · European CF chest CT guidance · Original PRAGMA-CF study · Paediatric CF modulator and MRI study · GINA 2026 strategy

Test Your Knowledge

A 3-year-old has high fever, drooling and a muffled voice. He sits leaning forward and becomes distressed if asked to lie down. What is the most appropriate immediate action?

A

Use a tongue depressor to examine the throat

B

Transfer the child to radiology to obtain a lateral neck radiograph

C

Allow his position of comfort, minimise distress and immediately summon an experienced paediatric airway team

D

Observe for one hour after nebulised adrenaline and discharge if stridor settles

Test Your Knowledge

A 28-week-gestation infant ventilated for respiratory distress syndrome develops, on day three, coarse linear and cystic radiolucencies confined to the right lung, with increasing oxygen requirement. What is the most likely diagnosis?

A

Transient tachypnoea of the newborn

B

Pulmonary interstitial emphysema

C

Meconium aspiration syndrome

D

Nosocomial pneumonia with empyema

Test Your Knowledge
Multi-Select

Which statements about neonatal chest imaging are correct? (Select all that apply)

Select all that apply

A supine neonate with pneumothorax may show marked hemithoracic lucency or a deep costophrenic sulcus, with pleural air collecting anteriorly or at the base

The spinnaker sail sign describes a tension pneumothorax compressing the thymus

The normal thymus can produce a sail sign with a straight inferior border and does not displace the airway or vessels

Transient tachypnoea of the newborn typically produces coarse asymmetric infiltrates with hyperinflation in a post-term infant

Sections you finish are checked off in the contents.