5.1 Cardiac CT, Coronary Artery Disease & Valvular Assessment

Key Takeaways

  • Coronary CT angiography depicts coronary anatomy and is particularly useful to exclude obstructive disease at low or moderate likelihood of chronic coronary syndrome. Heavy calcium, motion and irregular rhythm can make an individual segment unreadable.

  • A standard Agatston examination weights each calcified plaque area by peak attenuation. Coronary calcium indicates atherosclerotic burden. It cannot directly grade stenosis, and a score of zero does not exclude non-calcified plaque.

  • CAD-RADS codes the most severe evaluable stenosis and reports plaque burden, unreadable segments and modifiers when applicable. An unreadable segment is not normal.

  • For lesion-specific CT-derived fractional flow reserve, CAD-RADS 2.0 separates I+ at 0.75 or below, I± at 0.76–0.80, and I− above 0.80. Use the result with symptoms, anatomy and image quality.

  • For transcatheter aortic valve implantation, assess annular size in a high-quality preferably systolic plane, coronary and root relationships, calcium and arterial access. The Heart Team applies the intended device requirements.

Last updated: November 2026

Choose the Coronary Examination and Acquisition

In stable symptoms suspicious for chronic coronary syndrome, estimate the clinical likelihood of obstructive coronary disease. The 2024 ESC guidelines favour coronary CT angiography (CCTA) to rule out obstruction and identify plaque in patients with low or moderate likelihood when image quality is expected to be adequate. Functional imaging can assess inducible ischaemia when the anatomical result is inconclusive, an intermediate lesion needs assessment, or the baseline likelihood and clinical question favour functional imaging. CCTA cannot substitute for urgent assessment in a patient with signs of an acute coronary syndrome.

Trace the left main bifurcation and the left anterior descending, circumflex and right coronary arteries. Dominance is assigned by the origin of the posterior descending artery. Describe an anomalous origin with the proximal course and ostial morphology. A coronary artery with an intramural or interarterial proximal course and ostial narrowing needs specialist assessment; a retroaortic circumflex variant has different implications. Diagnostic lumen assessment requires adequate coronary enhancement, a reproducible breath-hold and sampling through the least-motion portion of the cardiac cycle.

AcquisitionWhen it helpsLimitation
Prospective ECG-triggeredA stable rhythm permits acquisition in a selected quiescent window, often mid to late diastole at low heart rates.Less flexibility with rate variation unless the scan allows padding.
Retrospective ECG-gated spiralWider phase coverage can rescue motion-limited segments or provide functional data when clinically needed.Greater radiation exposure than a narrow prospective window under otherwise comparable conditions.
Single-beat high-pitch or wide-coverageCan reduce motion-related slab discontinuities with suitable equipment, rhythm and trigger timing.Availability and phase flexibility depend on the scanner and acquisition strategy.

At faster rates the quiet diastolic window can shorten; review a systolic reconstruction when available. Check ECG trigger labels and the effect of ectopy before treating a step at a slab boundary as disease. Use patient- and scanner-appropriate tube potential and current. Beta blockade and sublingual nitrate can improve CCTA when indicated and safe. Screen for contraindications, including low blood pressure and recent phosphodiesterase-5 inhibitor use for nitrate, and use the prescribing and monitoring protocol of the department.

Calcium Scoring and CAD-RADS 2.0

The Agatston score on a standard noncontrast acquisition is the sum of the area of each calcified focus multiplied by a factor based on its peak attenuation:

Agatston score=∑iareai×fi\text{Agatston score} = \sum_i \text{area}_i \times f_i

For a standard 3 mm acquisition the factors are 1 at 130–199 HU, 2 at 200–299 HU, 3 at 300–399 HU and 4 at 400 HU or above. A 5 mm² focus peaking at 220 HU contributes 10 units. Use a validated acquisition and scoring method when comparing measurements or applying thresholds. The score measures calcified atherosclerotic burden; it cannot determine how much the lumen has narrowed. A high score can also limit lumen analysis because calcium blooms on angiographic reconstructions. Zero indicates no calcification detected with that method, with non-calcified plaque still possible.

CAD-RADS (Coronary Artery Disease Reporting and Data System) grades the greatest evaluable diameter stenosis and separately describes plaque burden and test limitations.

CategoryMaximum diameter stenosisInterpretation
00% with no plaqueNo coronary plaque or stenosis seen
11–24%Minimal stenosis, or plaque without appreciable narrowing
225–49%Mild stenosis
350–69%Moderate stenosis; consider physiological evaluation in the appropriate clinical setting
4A70–99% in one or two vesselsSevere stenosis; select further evaluation in context
4BLeft main at least 50%, or three-vessel obstructive disease (at least 70%)High-risk anatomy
5100%Occlusion; acuity and further assessment depend on context

Use P1–P4 for plaque burden from mild to extensive. Add the applicable modifiers N (non-diagnostic), HRP (high-risk plaque), I (ischaemia assessment), S (stent), G (graft) and E (exceptions for non-atherosclerotic disease). If an important segment is non-diagnostic but another has a confirmed moderate stenosis, retain the measurable grade and append N, for example 3/P2/N with moderate plaque burden. If all evaluable stenoses are below 50% and an important segment remains unreadable, CAD-RADS N communicates that obstructive disease cannot be excluded. The next test can be functional imaging or an alternative anatomical test, based on the symptoms and the reason for limitation.

Plaque Characterisation, CT-FFR and Artefacts

Describe calcified, non-calcified or mixed plaque. CAD-RADS 2.0 assigns HRP when a plaque has at least two of these high-risk CT findings. The CT signs are associated with risk without establishing histology or predicting when a lesion will rupture.

FeatureDefinition
Positive remodellingThe outer vessel diameter at the plaque is more than 1.1 times the mean outer vessel diameter of the proximal and distal reference segments.
Low-attenuation plaquePart of the non-calcified plaque measures below 30 HU.
Spotty calcificationPunctate calcification lies within the plaque.
Napkin-ring signA low-attenuation plaque region next to the lumen is surrounded by a rim of higher attenuation.

CT-derived fractional flow reserve (CT-FFR) estimates pressure loss from the CCTA data. In CAD-RADS use the lesion-specific value measured 1–2 cm distal to a stenosis. In a revascularisation-sized vessel, 0.75 or less supports an I+ designation, 0.76–0.80 is I± and greater than 0.80 is I−. The lowest pressure ratio at the end of a long vessel may reflect cumulative disease and does not independently identify a focal culprit. For a 50–69% lesion, a concordant abnormal value can support invasive assessment in a suitable symptomatic patient; a negative lesion-specific result can support deferral. The location, pressure drop across the lesion, symptoms and dataset quality still matter.

Artefacts to recognise and name:

  • Motion artefact - blurring or doubling of the contour, classically the mid right coronary artery; treat with heart-rate control, multiphase reconstruction and ECG editing.
  • Misregistration - the same segment appears offset between reconstructed slabs or phases, creating a false step in the vessel; caused by inconsistent cardiac phase or patient movement.
  • Step artefact - a visible discontinuity at a slab boundary in step-and-shoot acquisition, often mistaken for a stenosis.
  • Beam hardening and streak - dark bands radiating from dense calcium, stent struts or pacemaker leads, rendering segments non-diagnostic.
  • Blooming - calcium or stent metal appears larger than it is, systematically overestimating stenosis, particularly in small distal vessels.

Warning

A calcified plaque that produces a non-diagnostic segment (modifier N) must not be reported as a stenosis grade. State the limitation explicitly and explain the next test that could resolve the residual uncertainty when indicated.

Aortic Stenosis and Transcatheter Valve Planning

Echocardiography is the first-line way to assess aortic stenosis severity by combining peak velocity, mean gradient and valve area with flow and symptoms. Geometric area planimetry and the effective orifice from the Doppler continuity equation measure different quantities. If the echo measures are discordant and low-flow, low-gradient stenosis is suspected, the 2025 ESC/EACTS guideline supports use of aortic valve calcium scoring alongside the rest of the workup. Above 2,000 Agatston units in men or 1,200 in women supports severe stenosis; above 3,000 or 1,600, respectively, has higher specificity. Below 1,600 or 800 makes severe stenosis less likely. Use caution when severe stenosis can occur with relatively little calcium, as with some bicuspid or predominantly fibrotic valves. Dobutamine stress echo can help distinguish true severe from pseudo-severe stenosis in selected low-flow patients with reduced left ventricular ejection fraction.

For transcatheter aortic valve implantation (TAVI), use motion-free ECG-synchronised imaging of the root and map the access vessels separately as needed:

  1. Reformat the basal attachment points into a true annular plane. Prefer the largest high-quality systolic phase, and report area, perimeter and minimum and maximum dimensions. Match sizing to the chosen device.
  2. Measure both coronary heights from the annular plane and assess sinus dimensions, sinotubular junction and leaflet length and calcium. A low ostium combined with a small sinus or bulky leaflet can increase obstruction risk, so discuss the combined geometry and planned device rather than treating a single height as decisive.
  3. Report left ventricular outflow tract and annular calcium, bicuspid morphology, ascending aortic dimensions and any root pathology.
  4. Measure the narrowest usable arterial lumen along the access path, with calcification and tortuosity. Compare these findings with the device-specific access requirements and discuss alternatives with the Heart Team if transfemoral access is unsuitable.

CT can also map mitral annular calcification and anatomy for structural procedures, while echocardiography remains central to haemodynamic assessment. In an example with a 9 mm left coronary height and a narrow sinus, flag possible coronary obstruction for Heart Team planning rather than issuing a stand-alone procedural instruction.

See the 2024 ESC chronic coronary syndrome guideline, CAD-RADS 2.0 expert consensus, 2025 ESC/EACTS valvular guideline and ESCR transcatheter imaging consensus.

Test Your Knowledge

A 62-year-old with stable exertional symptoms has a 60% stenosis of the mid left anterior descending artery (CAD-RADS 3). CCTA is diagnostic and CT-FFR 1–2 cm distal to the lesion in a vessel of suitable calibre is 0.74. What is the best interpretation?

A

The value lies within the normal range, so the stenosis is non-flow-limiting and no further action is needed

B

This is a lesion-specific positive result under CAD-RADS 2.0 and supports discussion of invasive assessment in the clinical context

C

CT-FFR cannot be applied to intermediate stenoses and the result should be disregarded

D

The result mandates immediate surgical bypass grafting without any further assessment

Test Your Knowledge

A 66-year-old man with atypical exertional symptoms has an Agatston calcium score of 820. Which statement best describes the significance of this result?

A

It excludes obstructive coronary artery disease because calcified plaque is distributed diffusely

B

It falls in the mild range and only justifies repeating the score in five years

C

It shows a high calcified plaque burden and is relevant to cardiovascular risk, but cannot quantify luminal stenosis

D

It is diagnostic of a single haemodynamically significant left main stenosis

Test Your Knowledge
Multi-Select

Which statements about high-risk plaque features on coronary CT angiography are correct? (Select all that apply)

Select all that apply

Positive remodelling means the outer vessel diameter at the plaque is more than 1.1 times the mean outer diameter of the proximal and distal reference segments

The napkin-ring sign describes a densely calcified plaque with no low-attenuation component

Low-attenuation plaque is defined by attenuation of roughly less than 30 HU within the plaque on thin-slice images

Spotty calcification describes punctate calcium within the plaque

Sections you finish are checked off in the contents.