12.3 Image-Guided Biopsy, Localisation & Concordance
Key Takeaways
Choose guidance that depicts the actual target. An ultrasound finding must match the mammographic or MRI abnormality if it is used as a surrogate biopsy target.
For suspicious calcifications, check the sampled tissue with specimen radiography and reconcile calcification with pathology. A marker clip records the site and should not substitute for that check.
A benign histological diagnosis must explain the imaging and clinical finding. Resolve a suspicious mismatch promptly with review and further sampling or surgical excision.
For B3 lesions, consider the lesion type, atypia, extent, biopsy technique, residual finding and patient preference in multidisciplinary planning.
Choose the Guidance That Shows the Target
Review all relevant modalities before biopsy. Use ultrasound-guided core biopsy when the suspicious target is confidently visible and accessible. Real-time imaging can confirm needle position. For a target seen only on mammography, such as suspicious calcifications or distortion, use stereotactic or tomosynthesis guidance according to the lesion and local equipment. The parallax from paired images in stereotaxis or localisation in reconstructed tomosynthesis slices helps establish depth. MRI-guided biopsy is appropriate when a suspicious target is visible only on MRI and needs sampling. Make sure the intended target is safe to access before choosing a method.
Vacuum-assisted biopsy (VAB) can acquire larger-volume samples than standard core biopsy and is often used for mammographic calcifications or other small, difficult targets. Vacuum-assisted excision (VAE) is a distinct intent, used to remove selected lesions that merit that approach. A biopsy sample can remove all of the visible imaging target without proving all disease is gone. When sampling calcifications, obtain specimen radiographs to establish whether the target deposits were retrieved and communicate what was seen. If the specimen radiograph does not show the suspicious deposits, verify adequacy and reassess the target before accepting a benign result.
For example, segmental fine pleomorphic calcifications are visible on magnification views and there is no reliable ultrasound correlate. Use a mammographic guidance method and check the cores for calcifications. A coincidental small cyst in the same quadrant cannot serve as the target. EUSOBI image-guided biopsy and localisation recommendations.
Before biopsy, check consent, the planned side and target, relevant allergies, bleeding history, antithrombotic treatment and the ability to maintain the required position. Discuss any medication change with the responsible team using the local policy and the planned procedure, since interruption can also cause harm. Explain why a marker or additional imaging might be needed and arrange how the patient will get the result. After sampling, assess bleeding or haematoma and document any factor that makes concordance harder to judge.
Mark and Localise, Then Verify
A marker can preserve the original site when a small target is removed, a haematoma obscures the site or neoadjuvant treatment may erase the visible abnormality. The 2026 European pre-operative consensus also supports placement after MRI-guided sampling of an MRI-only lesion to aid later localisation. Document the marker type and location and its relation to the target, including any displacement. If a marker is deployed, two-view mammography can document its position under the European consensus pathway. An apparently well-positioned marker cannot confirm that sampling was representative.
For surgery on a non-palpable target, choose a wire, seed or other locally approved locator that the team can use reliably. Multiple localisers may bracket a larger extent when planned with surgery. Document the target and locator positions. In surgery for a calcification or marker target, specimen radiography can document whether these are present, help guide pathology sampling and inform intraoperative discussion. A clip in the specimen does not establish histological margin clearance. 2026 EUSOBI/ESSO/ESP/ESTRO pre-operative consensus.
Decide Whether the Pathology Explains the Imaging
Concordance means the pathology adequately accounts for the sampled appearance in its clinical context. A simple benign label can be entirely concordant for one target and unsafe for another. Check the intended site, procedural images, specimen findings and pathology. Consider whether the pathologist examined the calcified tissue when calcification was the target.
If a markedly irregular spiculated mass returns fibroadenoma or normal tissue without an adequate explanation, discuss discordance promptly with pathology and the breast team. Determine whether sampling missed the lesion or was insufficient. Arrange repeat image-guided sampling with the method that best targets it, potentially using larger-volume VAB, or surgical excision as appropriate. A routine six-month study does not resolve a suspicious discordance. A rapidly growing lesion with an earlier benign result also merits clinical and imaging reassessment.
Certain B3 lesions have uncertain malignant potential at the sampled site and may carry future risk. The European multidisciplinary guidance uses subtype, atypia, sampling and residual imaging findings to choose among surgery, selected vacuum-assisted excision and follow-up:
| Result | Questions for the breast team |
|---|---|
| Atypical ductal hyperplasia | How much was sampled, how extensive is the lesion, and is there any discordance? Surgical excision is generally preferred, with selected alternatives under a defined pathway. |
| Classical lobular neoplasia or flat epithelial atypia | Was it incidental or does it explain the targeted lesion? What remains after sampling? Non-classical lobular variants need a different assessment. |
| Radial scar or papilloma | Is atypia present? Is the lesion adequately sampled and concordant? Small lesions without atypia can have different treatment from those with atypia or inadequate sampling. |
A 61-year-old has an irregular non-parallel mass with angular margins. Ultrasound-guided core biopsy shows fibroadenoma and the team finds no explanation for the suspicious appearance. What is the best next step?
Accept the benign label and return to routine screening.
Defer all action until a repeat ultrasound in six months.
Resolve the discordance promptly with radiology–pathology review and appropriate repeat sampling or surgical excision.
Change the imaging assessment to BI-RADS 2 because a clip was placed.
A mammography-guided biopsy is performed for suspicious calcifications. The marker is well placed but specimen radiography shows no target calcifications. What should be done?
Accept benign histology automatically because of clip position.
Evaluate whether the target was sampled and arrange further targeting or sampling as needed.
Assume microscopic calcifications have been completely excised.
Use the marker position alone to report clear margins.
Sections you finish are checked off in the contents.