12.2 Diagnostic Breast Ultrasound, MRI, Axilla & Implants

Key Takeaways

  • Select the diagnostic examination by age, symptom and prior imaging. A suspicious clinical finding remains actionable even if ultrasound or mammography does not provide an explanation.

  • Use the modality-specific BI-RADS v2025 lexicon. Assess the shape, orientation, margin, echo pattern and posterior features together, and distinguish fluid with debris from a lesion with a solid component.

  • Assess axillary morphology, including the cortex, hilum and comparison with other nodes. Use image-guided sampling when the result can change management.

  • On MRI, judge morphology and distribution together with enhancement kinetics. Find a confident correlate before using ultrasound for a target first found on MRI.

  • Use noncontrast silicone-sensitive imaging for implant integrity when indicated. A new delayed peri-implant effusion or mass needs a separate diagnostic pathway.

Last updated: November 2026

Choose the Initial Examination for a Symptom

A focal breast symptom needs diagnostic assessment, even in a screening-age patient. In the EUSOBI symptomatic pathway, ultrasound is first in a woman younger than 30 and generally the modality of choice at ages 30–39, with mammography or digital breast tomosynthesis (DBT) added when indicated. At older ages diagnostic mammography or DBT and targeted ultrasound are often complementary. Adapt the examination to the finding, prior imaging, and pregnancy or lactation. A clinically suspicious palpable finding without a convincing imaging explanation still warrants specialist assessment. MRI is reserved for specific indications such as cancer staging, occult primary or selected unresolved diagnostic questions.

Document the site's clock position, distance from the nipple and whether the finding corresponds to symptoms or another modality. On ultrasound, examine in two planes and assess the tissue beyond the lesion as well as the margins. The BI-RADS v2025 ultrasound lexicon continues to use non-parallel orientation and non-circumscribed margins such as angular, indistinct, microlobulated and spiculated. Lobulated is a shape, distinct from the microlobulated margin. The ultrasound terminology differs from mammography. Non-mass lesions are distinguishable alterations of tissue that do not form a discrete mass. Describe their distribution, echo pattern and associated features. Doppler and elasticity can provide adjunctive information. Shadows and stiffness can also occur in benign tissue, particularly scar.

Ultrasound findingDecision
Simple cystAnechoic with a thin or imperceptible wall and typical through-transmission. A concordant asymptomatic simple cyst needs neither biopsy nor imaging follow-up. Aspiration can relieve symptoms if needed.
Complicated cystDebris or low-level echoes without a discrete solid component. Use mobility, fluid–debris layering and Doppler as appropriate to assess whether the contents are fluid. Management depends on diagnostic confidence and symptoms.
Clustered microcystsSeveral small cysts with thin septa and no discrete solid component. A classic appearance is benign.
Mixed solid and cystic massA genuine solid component such as a mural nodule raises suspicion. The older ultrasound term was complex cystic and solid. Biopsy should adequately sample the solid target.

See the EUSOBI symptomatic assessment recommendations and ACR v2025 ultrasound lexicon.

Assess the Axilla and Interpret MRI Enhancement

An oval or reniform axillary node usually has a preserved fatty hilum and a thin, even cortex. Focal cortical thickening, a rounded contour, displaced or effaced hilar fat and non-hilar vascularity raise suspicion. A cortex of 3 mm or less is a normal feature in the v2025 ultrasound lexicon, but the number alone does not distinguish reactive change from metastasis. Compare with the other side and integrate recent vaccination, infection and a known breast cancer. If sampling can change staging or treatment, target the most suspicious accessible node under ultrasound, with core biopsy or cytology according to local practice. Mark a proven positive node before systemic treatment where retrieval is planned.

On contrast-enhanced breast MRI, distinguish a three-dimensional enhancing mass from non-mass enhancement (NME) apart from background parenchymal enhancement. Describe NME distribution, such as focal, linear, segmental, regional or diffuse, and its internal pattern, such as homogeneous, heterogeneous, clumped or clustered ring. New segmental clumped enhancement warrants assessment in the appropriate setting. The morphology alone does not establish ductal carcinoma in situ.

Use both early and delayed enhancement to describe kinetics. In v2025, delayed washout means a signal decrease greater than 10% relative to the early phase, persistence is an increase greater than 10%, and plateau is a change within that band. For example, a decline from 200 to 170 signal units is (200 − 170) ÷ 200 = 15%, meeting the washout description if the measurement is technically reliable. Washout raises suspicion with other findings. Persistent enhancement does not exclude cancer. Normal glandular enhancement, motion and clip-related susceptibility can limit assessment. Document such limitations and avoid delaying urgent cancer work-up solely to optimise elective scheduling.

A second-look ultrasound uses the MRI location, depth and neighbouring landmarks to find a target. A nearby benign-appearing structure is not necessarily the same lesion. If no confident correlate is found and sampling is indicated, preserve the MRI finding for MRI-guided biopsy or an equivalent local pathway. See the ACR v2025 MRI lexicon and European pre-operative breast imaging consensus.

Diffusion-weighted imaging adds information about tissue water mobility. High diffusion-weighted signal with correspondingly low apparent diffusion coefficient can support restricted diffusion. Match the finding with enhancement and morphology, and account for distortion, signal from fluid and protocol. A low value alone does not determine malignancy. Contrast-enhanced mammography uses iodinated contrast and dual-energy acquisitions to pair anatomical low-energy views with recombined views that depict enhancement. It can help in a selected diagnostic pathway when MRI is unsuitable or unavailable. It requires its own contrast assessment and lexicon. EUSOBI diffusion consensus and ACR v2025 CEM lexicon.

Separate Implant Integrity From Peri-implant Disease

Check whether the implant contains silicone or saline and identify the shell and surrounding fibrous capsule. When silicone rupture is suspected, noncontrast MRI with silicone-sensitive sequences can show gel and the shell. Ultrasound is also useful for suspected complications and for evaluating fluid and nodes. Implant integrity and cancer detection are different imaging questions. Implant-displacement views can improve mammographic coverage of native breast tissue when appropriate.

Imaging findingInterpretation
Normal radial foldA shell infolding remains continuous with the shell. Follow it through adjacent slices.
Linguine signMultiple low-signal lines from collapsed shell within silicone. Supports intracapsular rupture if the gel remains within the fibrous capsule.
Stepladder signRepeated internal echogenic lines on ultrasound support shell collapse. Check for complex normal folds that can mimic it.
Keyhole or noose appearanceSilicone tracking between the shell and fibrous capsule along an invagination can support intracapsular failure. A fold alone is insufficient.
Silicone outside the fibrous capsuleIndicates extracapsular silicone. Search for free silicone in surrounding tissues, which can produce dirty shadowing on ultrasound. Assess implant integrity and history before using silicone in a node alone to date or prove rupture.

New swelling, a delayed periprosthetic effusion or a capsular mass, especially with a history of textured implants, raises concern for breast implant-associated anaplastic large cell lymphoma among other causes. Evaluate with ultrasound and coordinate sampling with pathology, including cytology and appropriate immunophenotyping such as CD30 and ALK. CD30 expression alone is insufficient for diagnosis. Do not treat a suspicious recurrent collection as a simple seroma without work-up. See the ACR breast implant evaluation update and the UK MHRA expert guidelines.

Test Your Knowledge

A 42-year-old has a painless palpable finding. Targeted ultrasound shows a concordant oval, circumscribed, anechoic lesion with an imperceptible wall and posterior enhancement. There is no solid component or other concern. What is the appropriate interpretation?

A

Simple cyst. No lesion-specific aspiration or follow-up is needed in this setting.

B

Complicated cyst requiring aspiration of internal debris.

C

Mixed solid and cystic mass requiring biopsy of a mural nodule.

D

Clustered microcysts requiring six-month surveillance.

Test Your Knowledge

Extent-of-disease MRI for known breast cancer shows a separate irregular suspicious enhancing mass that could change surgery. Its signal falls by 15% from the early to delayed phase. What should the report and work-up convey?

A

Persistent enhancement establishes benignity.

B

It shows washout. Seek a confident ultrasound correlate for biopsy, or sample with MRI guidance if it remains MRI-only.

C

It shows plateau. Defer evaluation for six months.

D

Kinetics cannot be evaluated without a silicone-only acquisition.

Test Your Knowledge
Multi-Select

Which statements about breast implant imaging are correct? (Select all that apply)

Select all that apply

The linguine sign can depict collapsed shell as multiple low-signal lines within the gel.

A stepladder pattern is a series of internal echogenic lines that can indicate intracapsular shell collapse.

Silicone in breast tissue beyond the fibrous capsule establishes an extracapsular component in the described rupture.

The keyhole appearance is the same as free silicone within pectoralis muscle.

Sections you finish are checked off in the contents.