11.4 Suspected Physical Abuse, Safeguarding & Paediatric Dose
Key Takeaways
Classic metaphyseal lesions and unexplained rib fractures in young infants raise serious concern. Interpret the findings with developmental ability, history, other injuries and potential medical mimics.
In the ESR/ESPR pathway, perform a dedicated skeletal survey in children younger than two years and a limited follow-up survey at 11–14 days. Initial head CT decisions depend on age and findings.
Abnormal head CT or ongoing high clinical suspicion can require MRI brain and whole spine within 2–5 days in the European acute pathway.
Describe the observed healing and the limits of timing. Document direct communication and continue the multidisciplinary safeguarding assessment.
Adapt protocols to child size and diagnostic task. The EU recommends weight-based body diagnostic reference groups and age-based head groups.
Fracture Patterns and Context
Assess each fracture in the context of age, developmental ability, the reported event and associated injuries. Classic metaphyseal lesions (CMLs) and unexplained rib fractures, including posteromedial lesions, raise particular concern in an infant. A corner fragment and a curved bucket-handle fragment can be projectional appearances of the same metaphyseal injury. Review both projections and obtain targeted views with the paediatric radiologist if uncertain.
| Finding | How to interpret it |
|---|---|
| Classic metaphyseal lesion or unexplained rib fractures in an infant | High concern. Document distribution and any concurrent injuries, and involve the child-protection team. |
| Multiple fractures, differing healing appearances or a fracture lacking a plausible explanation in a nonambulant child | Look for additional injury and seek clinical context. Fracture pattern and developmental history both matter. |
| Long-bone shaft or skull fracture | Describe site and morphology. A linear skull fracture or a spiral shaft fracture can occur accidentally. The entire history and examination determine concern. |
Consider fractures related to birth or treatment when the timing and clinical history support them. Possible mimics or contributing disease include osteogenesis imperfecta, rickets and metabolic bone disease of prematurity. Review bone density, metaphyseal appearance, history and supporting laboratory or genetic findings through the specialist team. The absence of a family history or blue sclerae does not exclude osteogenesis imperfecta.
Patterned bruising, or any otherwise unexplained bruise in a nonmobile infant, deserves careful clinical assessment. In the validated TEN-4-FACESp screening rule for a bruised child younger than four years, relevant features include bruising of the torso, ears, neck or specified facial or oral sites, any bruise in an infant younger than five months (published cutoff 4.99 months), and patterned bruising. A positive screen calls for clinical evaluation. The imaging decision depends on the wider assessment.
Skeletal Survey, Neuroimaging and Communication
In the ESR/ESPR pathway, use a dedicated initial skeletal survey in children younger than two years when physical abuse is suspected. Images include separate, collimated views of the skeleton, oblique views of both rib cages and focused views where indicated. A whole-body single projection misses detail. Skull radiographs may be omitted when suitable CT with multiplanar and three-dimensional reconstructions already provides equivalent assessment under the adopted protocol. At age two years and older, determine the need for a survey or targeted views case by case.
A limited follow-up survey at 11–14 days can disclose injuries that were occult initially and clarify indeterminate findings. The UK RCR/SCoR guidance specifies 11–14 days with an outer limit of 28 days. Follow the current local view list and image suspicious sites again when appropriate.
| Scenario | ESR/ESPR acute neuroimaging approach |
|---|---|
| Child younger than one year with suspected physical abuse | Noncontrast head CT with multiplanar and 3D reformats at initial assessment, in addition to the survey. |
| Child one to under two years | Decide on head CT case by case, using neurological findings, evidence of trauma and the level of concern. |
| Abnormal initial head CT, or normal CT with abnormal neurology or persisting high suspicion | MRI brain and whole spine within 2–5 days in the acute pathway. Coordinate with the safeguarding and paediatric teams. |
Check the relevant national pathway. The UK RCR/SCoR guideline also recommends initial head CT in children under one year with suspected physical abuse and uses clinical indications in older children. MRI characterises parenchymal injury, extra-axial collections and spinal injury. Record the distribution and appearance of blood or fluid. Mixed CT attenuation in a subdural collection has several explanations and cannot establish the number or timing of injury episodes.
Describe healing without false precision. Periosteal reaction, callus and remodelling occur over overlapping time intervals. Explain what was visible and compare prior images. Discuss urgent concerns directly with the referring and safeguarding teams, document the communication and follow jurisdiction-specific reporting procedures. Imaging informs a multidisciplinary assessment that considers clinical findings, other investigations and the history.
Paediatric Radiation Protection
Justify each ionising examination by weighing its benefit and risk. Use ultrasound or MRI where they can answer the question in the required time. The paediatric head CT in the acute pathway above illustrates a justified exposure. For any ionising study, optimise the technique for the child and the diagnostic task.
| Practical measure | Application |
|---|---|
| Child-specific technique and centring | Set protocols for size and task. Use tube-current modulation when configured for the examination and appropriately centre the child. |
| Scan coverage and phases | Cover the clinical area of interest. Use a single CT acquisition phase when adequate, and justify extra phases separately. |
| Reconstruction and image quality | Iterative reconstruction can support a lower exposure when validated for the relevant task. Evaluate diagnostic quality when revising the protocol. |
| Fluoroscopy | Collimate the field, use the lowest appropriate pulse rate and use last-image hold when suitable. |
Diagnostic reference levels (DRLs) are optimisation benchmarks for comparable groups of examinations. They do not set an individual patient dose limit. The 2026 Euratom recommendation favours weight groups for body examinations and age groups for head examinations in children. Compare local dose quantities with the applicable group and review image quality as well as dose. The European patient contact shielding consensus recommends against routine gonadal shielding in diagnostic X-ray imaging. A shield can obscure anatomy or interfere with automatic exposure control, so follow the procedure-specific protocol.
ESR/ESPR suspected abuse imaging · UK RCR/SCoR radiological investigation · AAP childhood fracture report · TEN-4-FACESp validation · Fracture healing cohort · Euratom Directive 2013/59 · Euratom Recommendation 2026/403 · European contact shielding consensus · Paediatric CT practice parameter
A 5-month-old infant has an unexplained posteromedial fracture of the left sixth rib. According to the ESR/ESPR approach, which next step is most appropriate?
Escalate promptly to the safeguarding team and arrange the initial skeletal survey and noncontrast head CT
Report the fracture as an incidental birth-related injury and take no further action
Repeat the chest radiograph in six weeks to confirm healing before any referral
Request a bone scan and defer any discussion with the clinical team until the result is available
Which statement best describes the radiologist's role when imaging raises concern about non-accidental injury?
The radiologist should state in the report that the child has been abused, because imaging provides the diagnosis
Radiology has no independent role and should simply report the films without comment on mechanism
Describe and document the findings and their limits, communicate the concern urgently and contribute to multidisciplinary assessment
The radiologist should assign an exact calendar date to each fracture so that a perpetrator can be identified
Which statements about paediatric radiation protection are correct? (Select all that apply)
Select all that apply
Routine gonadal shielding is the most effective way to reduce diagnostic radiography exposure in all children
Limit CT coverage to the diagnostic region and use size-appropriate acquisition and validated reconstruction settings
Use ultrasound or MRI when it can answer the clinical question safely and in time
A paediatric diagnostic reference level is the legal dose limit for each individual patient
Sections you finish are checked off in the contents.