12.1 Mammography, Digital Breast Tomosynthesis & BI-RADS
Key Takeaways
Check craniocaudal and mediolateral oblique views together. Use posterior tissue, the pectoral shadow and the inframammary fold to assess coverage and resolve genuine asymmetries.
Breast density can both obscure cancer and increase underlying risk. Supplemental screening depends on breast composition, other risk factors and the programme used.
Tomosynthesis reduces superimposition. A synthetic 2D image does not require a separate planar exposure, although total dose depends on protocol, system and breast thickness.
Use current BI-RADS v2025 mass descriptors, calcification morphology and distribution, and interval comparison. A new or more conspicuous focal asymmetry can warrant biopsy even if ultrasound shows no correlate.
An incomplete screening assessment requests additional evaluation or priors. After work-up, distinguish probably benign surveillance from a suspicious finding requiring tissue diagnosis.
Check Positioning Before Assessing an Apparent Lesion
For routine bilateral screening, the craniocaudal (CC) and mediolateral oblique (MLO) views show tissue from different directions. CC helps assess the medial and lateral extent. MLO uses an angle suited to the pectoral orientation to include posterior tissue, the axillary tail and the lower breast. A lesion can be visible on one view because tissue was excluded or because it is masked on the other. Review both views and prior images before deciding whether a focal density is summation.
| Quality check | How to use it |
|---|---|
| Posterior coverage | Assess retroglandular tissue and the pectoral extent on MLO. Seek coverage to nipple level or the posterior nipple line when feasible, and use the other coverage criteria in anatomic variants. |
| Nipple and lower breast | Seek a profile of the nipple on at least one view and check for the inframammary fold on MLO. A non-tangential nipple may mimic a superficial opacity. |
| Artefact and compression | Check for motion, skin folds and obscuring objects. Appropriate compression immobilises and spreads tissue and reduces thickness, scatter and dose for a given acquisition. |
| Comparison between views | Verify that medial, lateral and posterior tissue is included. A targeted repeat or alternative projection can be needed before calling a limitation acceptable. |
Breast composition ranges from mostly fatty (A) through scattered fibroglandular areas (B) and heterogeneously dense (C) to extremely dense (D). Categories reflect image appearance and can be impacted by masking; a fixed percentage should not be inferred. Dense tissue can obscure a cancer and is also independently associated with increased cancer risk. European policies for supplemental testing vary. EUSOBI recommends offering MRI every two to four years for women aged 50–70 with extremely dense breasts where feasible, while ECIBC evaluates supplemental screening for the specified organised programme and population separately. State the guideline and clinical population. NHS screening mammography guidance, EUSOBI dense-breast recommendations and ECIBC recommendations.
Use Tomosynthesis to Resolve Tissue Overlap
Digital breast tomosynthesis (DBT) obtains a set of low-dose projections over a limited arc and reconstructs planes through the compressed breast. Scroll through contiguous slices to follow the relationship of the finding to the surrounding tissue. A true distortion can have a centre of convergence across nearby slices. Seemingly radiating tissue that separates cleanly into normal structures can reflect summation. If doubt remains, use the appropriate additional projection, spot compression or targeted ultrasound. A negative ultrasound does not by itself resolve a suspicious mammographic finding.
A synthetic 2D image is reconstructed from projection or reconstructed DBT data, depending on the system, and avoids a separate digital mammography exposure. The total dose varies with equipment, breast thickness and protocol. A full extra 2D acquisition adds radiation. In the German TOSYMA randomised trial, DBT plus synthetic 2D detected more invasive cancers at screening than digital mammography. Detection at one round does not directly measure interval cancers or mortality. TOSYMA primary trial, TOSYMA dose analysis.
Describe the Finding Using BI-RADS v2025
An American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) report describes the findings and gives a linked assessment and next step. Describe a mass by site, size, shape, margin and density. A three-dimensional finding can be seen on two projections or consecutive tomosynthesis slices. In v2025 the mammographic shape terms include oval, lobulated, round and irregular. Margin choices include circumscribed, obscured, indistinct and spiculated. Older reports used other terms, such as microlobulated margin. A spiculated mass raises concern, but post-procedural scarring and fat necrosis can mimic it. A circumscribed margin alone does not prove benignity.
| Calcification morphology | What to look for |
|---|---|
| Usually benign | Skin, vascular, large rod-like, round, coarse, rim, layering or suture calcifications. A classic chunky involuting fibroadenoma can show coarse calcifications. |
| Suspicious | Amorphous, coarse heterogeneous, fine pleomorphic, or fine linear and fine linear-branching calcifications. Correlate with magnification views and distribution. |
Record both morphology and distribution. Coarse morphology from involution is different from coarse heterogeneous deposits. Layering in cysts often changes from smudged dots on CC to more defined dependent shapes on a true lateral image. Grouped, linear or segmental distribution can increase concern depending on morphology; recall that linear means arranged along a line, and a segmental pattern can trace a duct and its branches. Suspicious calcifications can have benign or malignant causes, so morphology alone does not establish histology.
An asymmetry is seen on one projection, a focal asymmetry in a confined area is seen in more than one, and a global asymmetry involves a larger area such as at least one quadrant without an associated suspicious finding. New or increasing conspicuity changes the work-up. v2025 drops developing asymmetry as a separate descriptor but asks that a new or more conspicuous focal asymmetry be regarded with suspicion. Architectural distortion is altered parenchymal architecture without a definite mass. Compare with previous operations and biopsy sites. An unexplained new distortion often warrants tissue diagnosis. Record associated features such as local skin or nipple retraction. ACR v2025 mammography lexicon and official changes.
Connect the Assessment to the Next Step
| Assessment | Practical use |
|---|---|
| 0, incomplete | Specify whether additional imaging or prior mammograms are needed, and resolve the examination before a final category. |
| 1, negative or 2, benign | Usual screening interval for the programme. In a symptomatic patient, also address whether imaging accounts for the clinical finding. |
| 3, probably benign | Limited to appropriate findings after diagnostic assessment, with expected probability at most 2%. The initial short interval is generally six months. |
| 4, suspicious | Recommend tissue diagnosis. Subcategories A, B and C indicate progressively greater suspicion. |
| 5, highly suggestive of malignancy | At least 95% likelihood. Tissue diagnosis and subsequent treatment planning, with review of any benign discordant pathology. |
| 6, known biopsy-proven malignancy | For established malignancy in the appropriate treatment setting. It is not a category of suspicion before histology. |
At a screening examination, a newly visible focal asymmetry may need diagnostic imaging before a final category. Use targeted projections and ultrasound as appropriate. If there is persistent concerning mammographic change and no satisfactory benign explanation, classify it as suspicious and sample under the modality that best depicts it. An ultrasound-negative but DBT-visible target can require DBT-guided biopsy. If prior comparison explains the finding, record what resolved it. An interval cancer is diagnosed after a negative screen and before the next scheduled screen, within the screening programme's definition. Its occurrence can reflect masking, a previously missed finding or cancer becoming detectable between rounds. Interpret audit rates with the programme's interval and population.
A 54-year-old at screening has a new 15 mm focal asymmetry on two views. The prior images are available and diagnostic work-up has not been performed. What is the appropriate next assessment in a programme using BI-RADS?
BI-RADS 2 — benign finding; return to routine screening at the national interval
BI-RADS 3 — short-interval follow-up in six months
Incomplete assessment (BI-RADS 0) for additional imaging; biopsy if the finding remains suspicious
BI-RADS 6 — known biopsy-proven malignancy requiring treatment planning
Which calcification morphology is classically benign and, in a scattered distribution, does not by itself require biopsy?
Fine linear and branching calcification
Amorphous calcification
Fine pleomorphic calcification
Coarse, popcorn-like calcification
Which statements about mammographic technique, density and tomosynthesis are correct? (Select all that apply)
Select all that apply
Posterior tissue coverage and inclusion of the inframammary fold help assess positioning on the mediolateral oblique view
A density seen on only one view can be assumed to be summation artefact and reported as benign without further imaging
Dense breast tissue both masks existing cancers and is associated with an increased intrinsic risk of breast cancer
A synthetic 2D image uses tomosynthesis data and can avoid a separate planar mammographic exposure
Sections you finish are checked off in the contents.