14.3 Basic Nuclear Medicine & Radionuclide Scintigraphy

Key Takeaways

  • A collimated gamma camera records single photons. SPECT reconstructs activity from multiple directions. PET uses coincidence detection of annihilation photons.

  • Match tracer handling to the clinical question. Collecting-system drainage, renal cortical function, tissue perfusion and receptor expression require different protocols.

  • A pulmonary vascular mismatch is assessed with the interpretation rules for the acquired technique. The 2026 joint standard defines a positive V/Q SPECT pattern at one segment or two subsegments.

  • An anomalous uptake pattern can reflect physiology, technical error or several diseases. Read the tracer’s distribution with the anatomical images and clinical history.

  • EU law distinguishes diagnostic optimisation from individually planned therapy. Document the activity and give appropriate patient instructions under national implementation.

Last updated: November 2026

From Radionuclide to Image

Choose the radionuclide for its emissions, physical half-life and practical availability. Choose the chemical form for the biological question. A radionuclide may be part of a labelled compound or administered as an ion. Technetium-99m has a physical half-life of about 6 hours and emits a principal photon around 140 keV, suitable for a gamma camera. Patient retention also depends on biological clearance. Section 2.6 works through physical, biological and effective half-life.

A gamma camera uses a collimator to accept photons along selected directions. Planar imaging superimposes activity through depth. SPECT uses multiple projections to reconstruct a volume, improving localisation. SPECT/CT can combine that volume with anatomical information and attenuation correction. PET uses paired 511 keV annihilation photons and coincidence timing to estimate a line of response. In PET/MR, MR supplies anatomy and other tissue information while the system must separately estimate attenuation.

Before interpreting a focal finding, check count statistics, motion, calibration or uniformity indicators and hybrid registration. If attenuation correction introduces a focus near metal or a tissue boundary, compare the corrected and uncorrected data and anatomical images. Choose imaging delays and positioning for the target, and review the normal distribution before calling abnormal uptake.

From Bone Turnover to Infection

Bone scintigraphy with a technetium-99m-labelled diphosphonate reflects blood flow and bone turnover. Three-phase imaging compares dynamic perfusion, early blood-pool images and delayed skeletal uptake. Increased uptake on all phases can support osteomyelitis, with lower specificity after trauma, surgery or prosthesis. Review anatomy and consider MRI or another targeted evaluation when the location or cause remains uncertain.

A superscan shows striking skeletal uptake relative to soft tissue, often with faint renal activity. Widespread osteoblastic metastases and metabolic bone disease can produce this pattern. Distribution, skeletal morphology, renal function and clinical context help distinguish them. Treatment-related healing also may increase uptake. Review the staging or response framework before changing management.

In selected cases of suspected prosthetic joint infection, labelled leukocyte imaging can be compared with marrow scintigraphy. Leukocyte uptake discordant with marrow supports infection. Concordant uptake can reflect altered marrow distribution after surgery. Use the clinical and microbiological criteria alongside imaging.

Endocrine, Renal and Hepatobiliary Questions

Clinical questionBiological process and pattern
Hyperthyroidism or a thyroid nodule with low TSHIodine-123 is trapped and organified. Technetium-99m pertechnetate is trapped without organification. Diffuse increased uptake supports Graves disease, focal uptake with suppressed background supports autonomy, and markedly reduced uptake can occur with destructive thyroiditis or recent iodine exposure.
Localisation before parathyroid surgeryConsider ultrasound and technetium-99m sestamibi or other localising imaging after biochemical diagnosis. Delayed relative retention can help, with overlap between parathyroid lesions and thyroid nodules. SPECT/CT gives an anatomical target, including ectopic sites.
Is a dilated collecting system obstructed?Dynamic technetium-99m MAG3 with a diuretic assesses relative function and drainage. Adequate hydration, renal function, timing and bladder emptying affect drainage. Technetium-99m DTPA is filtered and can be selected for particular functional questions.
Is there renal cortical injury or reduced relative cortical function?Technetium-99m DMSA maps functioning renal cortex. Interpret defects in the clinical context and distinguish acute defects from persistent scarring with appropriately timed follow-up.
Is tracer able to enter the gallbladder or pass into bowel?A hepatobiliary iminodiacetic acid tracer follows hepatocyte uptake and biliary excretion. Persistent gallbladder nonvisualisation after the indicated delayed or augmented imaging supports cystic duct obstruction in the appropriate setting. Check fasting, severe illness and liver function.

In suspected renal obstruction, a technically valid MAG3 washout half-time below 10 minutes excludes obstruction in the adult diuretic renography guideline. A long value in isolation is insufficient. For example, if a large collecting system retains tracer during supine imaging but empties well after voiding and upright drainage, review those images and renal function before diagnosing obstruction.

For a thyroid nodule, correlate scintigraphy with ultrasound to establish that the same nodule is hyperfunctioning. The 2023 European Thyroid Association guideline generally avoids biopsy of a hyperfunctioning nodule unless it is highly suspicious. For a hypofunctioning nodule, use ultrasound risk and size criteria to decide on sampling.

Match Ventilation, Perfusion and Dynamic Findings

For ventilation–perfusion (V/Q) SPECT, ventilation may be mapped with a suitable gas or aerosol and perfusion with intravenous technetium-99m macroaggregated albumin. In the 2026 joint guideline, a positive pulmonary embolism pattern comprises a mismatch of at least one segment or two subsegments, in the anatomical distribution of pulmonary vessels. On a combined study, inspect CT for structural explanations. For example, a peripheral wedge of reduced perfusion with preserved ventilation that occupies a segment and has no alternate explanation supports PE. A matched defect with corresponding consolidation offers a different explanation and the entire examination still needs review. Interpret planar or perfusion-only acquisition according to its own scheme and context.

Gated myocardial perfusion SPECT compares tracer distribution at stress and rest. A stress defect that improves at rest supports inducible ischaemia. A fixed defect may represent infarct or attenuation. Check gated wall motion and thickening, motion and the corrected images before assigning scar.

For intermittent gastrointestinal bleeding, serial labelled red-cell imaging can reveal a focus that appears outside normal blood pool, increases and moves along bowel over time. Localise the first appearance before bowel transit displaces the tracer. In a patient needing urgent localisation and intervention, the immediate pathway depends on haemodynamic status and available services. A Meckel scan with technetium-99m pertechnetate detects functioning ectopic gastric mucosa. Its diagnostic question is distinct from localisation of active bleeding.

Receptors, Treatment and Radiation Safety

Tracer or agentApplication and interpretation
Gallium-68 or copper-64 somatostatin-receptor PET agentMaps somatostatin-receptor expression in appropriately selected neuroendocrine tumours. Use clinical and anatomical correlation.
PSMA PET agentMaps PSMA-targeted uptake in defined prostate cancer settings. Physiological uptake and selected benign or other malignant processes can be avid.
Iodine-123 MIBGImages adrenergic uptake in neuroblastoma and selected phaeochromocytomas and paragangliomas. Match the tracer to disease and imaging purpose.
Iodine-123 ioflupaneMaps striatal presynaptic dopaminergic terminal integrity in selected parkinsonian presentations. It cannot reliably identify a single degenerative parkinsonian syndrome from the deficit alone.
Lymphatic radiocolloidMaps initial drainage to sentinel nodes in eligible patients. The scan localises the node for sampling. Histology determines whether it contains tumour.
Amyloid or tau PETMay answer a defined clinical question in selected patients with cognitive symptoms after evaluation. Indication and availability depend on the tracer and jurisdiction.

Theranostic pairs use related targeting for imaging and treatment. In EU practice, lutetium-177 DOTATATE has a defined indication for progressive, unresectable or metastatic well-differentiated, somatostatin-receptor-positive gastroenteropancreatic neuroendocrine tumours. Lutetium-177 vipivotide tetraxetan also has specific EU eligibility for PSMA-positive metastatic castration-resistant prostate cancer. Imaging demonstrates the target. The treatment team separately checks the approved indication, prior treatment, organ function and relevant contraindications.

For a diagnostic examination, justify the indication, verify patient and activity, check pregnancy and breastfeeding when relevant, and optimise administered activity and CT exposure for the clinical task. Diagnostic reference levels guide protocol review. Apply local handling, contamination checks, shielding, staff monitoring and incident processes. For therapeutic use, EU radiation protection law requires individual planning and appropriate verification. Provide written instructions before the patient leaves after radionuclide therapy. Assess discharge under the applicable national and local criteria and give situation-specific advice covering carers, contact and possible contamination.

Test Your Knowledge

A prosthetic knee has focal labelled leukocyte activity. Which comparison best tests whether that focus reflects altered marrow distribution rather than providing specific support for infection?

A

Planar ventilation–perfusion scintigraphy

B

Marrow scintigraphy alongside the labelled leukocyte study

C

DMSA renal cortical imaging

D

PERCIST measurement on the leukocyte image

Test Your Knowledge

Under the 2026 joint V/Q SPECT standard, a patient has two peripheral, vascular-shaped segmental perfusion defects with preserved ventilation. CT shows no alternative cause at those sites. How should this pattern be classified?

A

Negative for PE because ventilation is preserved

B

Indeterminate until a third segment is involved

C

Positive for PE because the vascular mismatch meets the SPECT criterion

D

Positive for PE only if both areas also show reduced ventilation

Test Your Knowledge
Multi-Select

Which tracer and intended diagnostic question are paired correctly? Select all that apply.

Select all that apply

Technetium-99m DMSA for renal cortical defects and relative cortical function

Iodine-123 MIBG for adrenergic uptake in selected neuroblastoma

Technetium-99m MAG3 as the standard tracer for mapping renal cortical scars

Technetium-99m sestamibi for demonstrating pulmonary vascular mismatch

Sections you finish are checked off in the contents.