15.1 DICOM, PACS, Display Standards & De-Identification
Key Takeaways
The DICOM hierarchy uses Study, Series and SOP Instance UIDs for object identity. Patient identifiers need their issuing context.
Transfer syntax specifies the encoding of the data set. Worklist, storage, query/retrieve and Storage Commitment serve distinct purposes.
GSDF addresses grayscale presentation. Diagnostic display QA also measures luminance, contrast response, uniformity and the effect of ambient light.
Apply the relevant PS3.15 profile and options. Inspect pixel annotations, private data, linked objects and recognisable anatomy where applicable.
Under the GDPR, pseudonymisation with a separately held key is a safeguard. Assess identifiability and release conditions in the relevant context.
Identify the Patient, Study, Series and Instance
DICOM (Digital Imaging and Communications in Medicine) defines information objects, data encoding, files and communication services. In the composite imaging model, a patient has studies, a study contains series, and a series contains instances. An instance may hold a single image, a multiframe set, a segmentation or a structured report. A study may contain several acquisitions, reconstructions or derived result series. Order and visit details are managed separately and checked against the imaging record.
A Patient ID belongs to an issuing context. An accession number identifies the imaging service request in its issuing context. Study Instance UID, Series Instance UID and SOP Instance UID identify the relevant instances across systems. For example, a CT acquisition and a separate thin-section reconstruction may use different Series Instance UIDs within the same study. The receiver groups imported objects using these identifiers and positions the slices from image geometry. Arrival order and file name carry no guarantee of anatomical order.
Each data element has a tag expressed by hexadecimal group and element numbers. Examples include (0010,0010) Patient Name, (0008,0060) Modality and (0020,000D) Study Instance UID. A value representation (VR) defines the type of value, such as PN for Person Name, DA for Date and UI for Unique Identifier. With explicit VR the type is encoded within the element. With implicit VR the standard dictionary provides the VR where defined. Sequences may contain nested data sets.
A transfer syntax describes the data set encoding, including byte order, VR encoding and how pixel data is represented. Classic DICOM participants negotiate acceptable presentation contexts for an association. A file carries its transfer syntax in its file meta information. Lossless encoding preserves the reconstructed pixel values, while lossy encoding can change them. The diagnostic feasibility of a chosen compression depends on the task and local validated policy. Re-encoding previously lossy data in a lossless syntax cannot recover the discarded information.
Follow the Order from Acquisition to Reporting
| Workflow or service | What it does |
|---|---|
| RIS or hospital information system | Receives the order, schedules the examination and supports reporting and delivery of results to the clinical record. IHE Scheduled Workflow.b defines interoperable system roles. |
| Modality Worklist | Provides patient and scheduled-procedure details using the DICOM worklist query so they can be reconciled at acquisition. Staff still verify identity and procedure. |
| Storage and retrieval | Classic DICOM uses C-STORE for storage, C-FIND for query and C-MOVE or C-GET for retrieval in the relevant services. DICOMweb supplies HTTP services including STOW-RS, QIDO-RS and WADO-RS. |
| Storage Commitment | The archive takes an explicit safekeeping commitment for specified instances under its declared implementation. A C-STORE success response by itself carries no such commitment. Follow local retention and recovery policy before discarding a modality copy. |
| PACS, viewer and clinical record | PACS links stored imaging objects and retrieval to the viewing workflow. The viewer uses the study, series and object references. HL7 messages or FHIR resources can carry details such as orders and results in the clinical workflow. |
IHE profiles specify how participating actors use DICOM, HL7 or other standards for a workflow. For example, if two hospitals give an order the same accession string, use the accession issuer where available and reconcile patient and study identity before merging work. A cancelled order left on the worklist needs reconciliation between the order and scheduling systems. A clinical report and its structured image analysis may have different delivery paths.
Check the Display and Image Presentation
DICOM PS3.14 defines a Grayscale Standard Display Function (GSDF) that relates presentation values, perceived through just-noticeable-difference steps, to luminance. The model is defined over 0.05–4,000 cd/m². This is the range of the mathematical function. The acceptance criteria for actual displays depend on the intended task. Calibration and periodic QA evaluate the measured luminance response, minimum and maximum luminance, uniformity and ambient light. A diagnostic mammography display and a ward review display have different task requirements.
Ambient reflection can increase the displayed black level and reduce the visibility of low-contrast detail. Evaluate the screen in its normal reading environment with an appropriate test pattern and, where indicated, a calibrated measurement device. When a finding appears differently across monitors, compare the source series, hanging protocol, window settings and display QA before attributing the difference to hardware.
De-identify the Objects and Check the Release
DICOM PS3.15 Annex E describes the Basic Application Level Confidentiality Profile and options. Determine what must be removed, replaced or consistently remapped across associated objects. Match the options to the approved purpose. For a longitudinal research dataset, modified dates may preserve usable intervals under an explicitly selected option while reducing exposure of original dates.
- Burned-in text. A name in the pixel values of an ultrasound image survives changes to metadata. The Clean Pixel Data Option requires the relevant identification to be removed from stored pixel data. A display-only mask leaves the original values accessible. Use a workflow appropriate to the acquisition, such as validated automated detection and visual checking where indicated.
- Other pixels and content. Distinguish burned-in text from graphics, structured content and recognisable facial anatomy. The profile has separate options for these risks. Check the relevant images and derived objects, including reports, segmentations, overlays and reconstructions where applicable.
- Private data. Private elements can contain technical settings or identifiers. The basic profile calls for removing private attributes unless the applicable safe-retention option is used for attributes known to be safe. Removing only familiar public identifiers is incomplete.
- Linkage and context. Retain only approved linkage, with coherent identifier remapping and a separate protected key when required. Under GDPR Article 4(5) and Recital 26, pseudonymisation is a safeguard and data remain personal to a controller able to re-identify the patient. Assess anonymity in view of the means reasonably likely to be used for identification, including linkage with other information. Escalate the assessment of a specific release to the responsible governance team.
For example, consider exporting a study with a remapped image series, a reformatted screenshot and an AI result. Check that the screenshot contains no identifying text, the AI object's references follow the remapping and any intended appearance or date retention is authorised. Validate the export with representative cases before release.
Deliver Structured Results to the Correct Study
DICOM Structured Report (SR) represents findings as a tree with coded concepts and typed values. Some reports use templates for consistent measurements and observations. A DICOM Segmentation (SEG) object can carry masks linked to the relevant image instances. For example, an AI result can use measurement SR and a referenced SEG. The IHE AI Results profile specifies how participating systems exchange, store and present such outputs. Link the result to the study and the source objects required to display it correctly. Verify that the result arrives within the intended workflow, that failures are visible and that the radiologist can compare it with the source images.
DICOM PS3.3 Series modules · DICOM PS3.4 modality worklist · DICOM PS3.4 Storage Commitment · DICOM PS3.5 data set encoding · DICOM PS3.5 UIDs · DICOM PS3.14 GSDF · AAPM TG270 display QA · DICOM PS3.15 Annex E options · DICOM PS3.18 DICOMweb · IHE Scheduled Workflow.b · IHE AI Results · GDPR Article 4 and Recital 26
After CT images have been copied individually to a research server, which statement describes the role of the Series Instance UID?
It identifies the patient across every hospital encounter, so it must remain stable for life
It identifies the series to which the instances belong, so a receiver can group those objects even when they arrive separately
It declares the encoding and compression of the pixel data so the receiver knows which codec to use
It records which radiographer authorised the acquisition and therefore who owns the images
A registry applies the DICOM Basic Application Level Confidentiality Profile to attributes in obstetric ultrasound images. The export process does not inspect or alter the image pixels. Which identifier could survive the process?
Patient Name as an attribute retained by default under the basic profile
A patient identifier encoded by the pixel compression codec
The patient’s name burned into the ultrasound pixel values
The radiologist’s identity embedded in the transfer syntax
Which statements about PACS integration and diagnostic display standards are correct? (Select all that apply)
Select all that apply
Storage Commitment provides an explicit safekeeping commitment for the specified instances, beyond a successful C-STORE response
The DICOM Grayscale Standard Display Function relates presentation values to luminance using steps based on visual discrimination
HL7 clinical results messaging is the standard DICOM service for transmitting pixel data to the archive
IHE Scheduled Workflow.b replaces both HL7 and DICOM with a proprietary protocol