14.2 FDG PET-CT Principles, Pitfalls & Artefacts
Key Takeaways
FDG is transported into cells and phosphorylated by hexokinase. The signal reflects glucose handling in many tumours and in normal or inflamed tissues.
For routine adult tumour imaging, fast according to protocol, measure glucose before injection and document uptake time. Use comparable uptake and reconstruction conditions for follow-up quantification.
SUV depends on injected activity, the normalisation method and image resolution. PERCIST uses SULpeak, which normalises a small-volume mean to lean body mass.
Check the anatomic correlate and corrected and uncorrected images when metal, respiratory misregistration or truncation may alter an apparent focus.
Small or intrinsically less avid tumours can be missed. Infection, treatment effects and physiological activity can mimic tumour. Interpret the metabolic finding with prior scans and morphology.
FDG Preparation and Quantification
Fluorine-18 fluorodeoxyglucose (FDG) enters cells through glucose transporters and is phosphorylated by hexokinase. FDG-6-phosphate undergoes limited further metabolism compared with glucose-6-phosphate and can accumulate intracellularly. Avidity varies with tumour biology and is also seen in normal brain and activated inflammatory cells.
For routine adult oncologic FDG PET/CT, EANM version 3.0 advises fasting per protocol, measuring glucose before injection and keeping the patient resting and warm for uptake. Acquisition usually starts around 60 minutes after injection. Document the actual interval, and reproduce it and other technical factors closely in serial response studies. Keep the dedicated myocardial suppression protocol separate.
The EANM clinical guidance generally permits the examination below 11 mmol/L (about 200 mg/dL) and favours rescheduling at or above this level when circumstances permit. A protocol requiring quantitative SUV may specify a stricter upper limit, for example 7–8.3 mmol/L. Check the applicable protocol. Do not treat the threshold as an absolute contraindication.
The body-weight standardised uptake value is:
Worked example. With 6,000 Bq/mL in tissue, 210 MBq net administered activity decay-corrected to the same reference time and a weight of 70 kg, the normalising value is 3,000 Bq/g and the conventional SUVbw value is 2.0. A calculation cannot correct for a poorly documented injection or mismatched uptake times.
| Metric | Measurement and limitation |
|---|---|
| SUVmax | Highest voxel value in the region. Sensitive to noise and reconstruction. |
| SUVmean | Mean of a volume, dependent on how the lesion is outlined. |
| SUVpeak | Mean over a small defined volume placed to sample the area of highest uptake. |
| SULpeak | Peak measurement using lean-body-mass normalisation. The original PERCIST framework uses an approximately 1 cm³ volume. |
Failure to resolve a small target spreads apparent activity into adjacent voxels. This partial volume effect can lower measured uptake in a subcentimetre nodule. The magnitude depends on size, contrast, motion and reconstruction. There is no universal lesion-size cutoff or SUV threshold that establishes malignancy.
Read the Distribution Before Naming a Lesion
The brain normally has prominent cortical uptake. Myocardial uptake on a standard tumour study is variable. The liver commonly provides a reference, with mediastinal blood pool also used for the Deauville scale. Physiological bowel activity varies and can increase with metformin. Excreted activity in the urinary tract can mimic a focus in an adjacent node, so trace the ureter on CT.
Activated brown fat can be FDG-avid, often in the neck, supraclavicular and paravertebral regions. Confirm that activity maps to fat and consider the overall distribution. Muscular activity, lymphoid tissue, thymus in younger patients, and stimulated marrow can also be conspicuous. Use the uptake pattern, CT appearance and treatment history together. A symmetric distribution can help identify a physiological explanation, while an unexplained structural lesion or focal finding still needs assessment.
Check Attenuation Correction, Registration and Injection
| Finding | How to investigate it |
|---|---|
| Focus at a lung base or liver dome | Compare the diaphragm on PET and CT. Different breathing phases can displace a real focus or produce an attenuation artefact. Motion can blur a lesion and lower its peak value. |
| Focal apparent uptake next to dense metal or contrast | Check the CT, the geometry of the focus and the non-attenuation-corrected PET. CT attenuation values can propagate errors to corrected PET. |
| Cropped body contour on CT | Truncation can bias uptake near the edge. Check field of view and consider positioning or correction options compatible with the clinical indication. |
| Prominent injection-site or lymphatic activity | Check the injection and record suspected extravasation or dose uncertainty. The whole-study quantitative comparison may be affected. |
| Intense small pulmonary focus without a CT correlate | Check registration first. If the finding is still unexplained, consider a labelled microembolus as well as a lesion below CT visibility. Use the injection history and judicious follow-up. |
| Superficial intense pelvic focus | Inspect the skin, clothes and anatomic localisation for urinary contamination. Clean and reacquire focused images when appropriate. |
Compare corrected and uncorrected PET to diagnose attenuation-related findings. An image seen on uncorrected PET can still represent physical tracer activity unrelated to the suspected disease, such as urinary contamination.
Distinguish Low Avidity From Absence of Disease
Infection, granulomatous disease, healing after surgery or radiotherapy and immune-mediated reactions can be FDG-avid. For new bilateral hilar uptake during immune checkpoint therapy, correlate with other sites of response, clinical findings and earlier studies. A sarcoid-like reaction can mimic progression, and tissue or follow-up may be needed when the distinction changes care.
A hypocellular mucinous adenocarcinoma may be weakly avid even when large. Some low-grade neuroendocrine and invasive lobular breast tumours have lower FDG uptake. Select tracer or modality by the indication. For example, somatostatin-receptor PET can show receptor-positive neuroendocrine tumour, and FDG can add information in more aggressive or heterogeneous disease. PSMA-targeted imaging has specific uses in prostate cancer. High physiological brain uptake limits FDG contrast for detecting brain metastases, where dedicated contrast-enhanced MRI is usually preferred.
Use PERCIST with reproducible quantitative preparation and follow-up for the specified solid-tumour assessment. Use Lugano visual categories in the applicable FDG-avid lymphoma setting. RECIST 1.1 uses anatomic measurements and separately assesses new lesions. Section 14.1 explains how these systems classify change.
Match the Protocol to the Clinical Question
For an indeterminate solid pulmonary nodule, combine clinical and CT risk with the sensitivity of the local PET technique. As one example, the UK BTS pathway selects nodules above the local PET detection limit and above its specified pretest risk threshold. A negative result in a small or subsolid nodule should be interpreted with CT morphology and growth. In selected patients with cancer of unknown primary, PET can help assess extent or identify a potential biopsy site. Integrate pathology, especially when a new focus could redirect treatment.
For selected adults with persistent fever or inflammation of unknown origin, FDG can help localise a process after clinical evaluation. In suspected cardiac sarcoidosis, apply targeted myocardial suppression preparation. Interpret focal uptake together with perfusion, clinical context and adequacy of suppression. In large-vessel vasculitis, the updated 2026 joint guideline evaluates arterial pattern, intensity and distribution. Atherosclerosis, vascular infection and treatment can affect interpretation. Repeat imaging for treatment assessment is selective.
EANM FDG tumour imaging v3.0 · PERCIST original · Lugano consensus · Joint hybrid CT attenuation guidance · Pulmonary hot-clot case-control study · Mucinous tumour histopathology study · EANM breast FDG guideline · Joint immunotherapy PET guideline · SSTR PET standard · PSMA PET standard · BTS nodule guideline · ESMO unknown primary guideline · EANM/SNMMI infection imaging v2.0 · Cardiac sarcoidosis consensus · 2026 joint vasculitis PET guidance · Joint PET guidance on brain metastases
On FDG PET/CT, SUV measurement of a 7 mm pulmonary nodule is less reliable than measurement of a readily resolved 25 mm lesion. Which effect can underestimate uptake because the smaller lesion approaches the scanner’s spatial resolution?
Partial volume averaging with the background
A benign-specific SUV cutoff
An SUV normalisation that is independent of patient or scanner factors
A universally reduced uptake in small lesions when acquisition is delayed
Which tumour can be poorly detected by FDG PET/CT even when bulky because it contains abundant extracellular mucin and relatively few viable cells?
Small-cell lung carcinoma
High-grade diffuse large B-cell lymphoma
Squamous cell carcinoma of the head and neck
Hypocellular mucinous adenocarcinoma
Which statements about FDG PET-CT artefacts and pitfalls are correct? (Select all that apply)
Select all that apply
Prominent injection-site retention can affect quantitative comparison and should be documented
Dental amalgam or an orthopaedic prosthesis can produce attenuation-correction artefacts that create apparent focal uptake
Truncation caused by arms or body lying outside the CT field of view can produce spurious activity values at the edge of the reconstructed image
Misregistration between PET and CT caused by respiration usually improves the accuracy of lesion localisation in the lung bases
Sections you finish are checked off in the contents.