5.3 Acute Aortic Syndromes, Aneurysms & Repair Surveillance
Key Takeaways
In suspected acute aortic syndrome, use appropriate urgent CT angiography. An unenhanced phase can identify mural blood and ECG synchronisation reduces ascending aorta motion artefact.
Ascending aortic involvement is Stanford type A and needs immediate specialist referral. For disease sparing the ascending aorta, report the exact entry and extent, including any arch involvement, branch compromise or rupture.
Measure perpendicular to blood flow and document the edge and plane convention. Compare serial abdominal aneurysm measurements using the same ultrasound method when possible.
Retroperitoneal or pleural haematoma contiguous with an aneurysm, wall disruption and active extravasation can indicate rupture. A hyperattenuating crescent by itself is insufficient to diagnose rupture.
After endovascular repair, assess the sac, sealing zones, graft integrity and branch patency. Type I and III endoleaks communicate directly with systemic pressure and warrant prompt specialist assessment.
Diagnose Acute Aortic Syndrome and Report Its Extent
Acute aortic syndrome includes dissection, intramural haematoma and penetrating atherosclerotic ulcer. In a stable patient, urgent computed tomography angiography (CTA) should cover the aorta from root through the iliofemoral arteries as appropriate. A short unenhanced acquisition helps identify mural blood. ECG synchronisation of the root and ascending aorta reduces motion-related pseudoflaps. Consider a delayed acquisition for a specific problem such as slow false-lumen filling. If a patient is too unstable for CT, the acute aortic team may use bedside or perioperative transoesophageal echocardiography.
| Entity | Imaging discriminator |
|---|---|
| Dissection | A flap separates true and false lumens. Trace it in several planes or phases when a short ascending line might be from motion. |
| Intramural haematoma | High-attenuation crescentic or circumferential mural thickening on unenhanced CT, without a patent false lumen. There may be a focal intimal disruption or later evolution into dissection. |
| Penetrating atherosclerotic ulcer | A contrast-filled crater extending through the intimal contour into the aortic wall, usually with marked atherosclerosis. Distinguish it from a superficial ulcerated plaque. |
Stanford type A dissection involves the ascending aorta regardless of entry site. Seek immediate aortic surgical assessment. Type B in the usual Stanford scheme spares the ascending aorta. Describe disease confined to or originating in the arch separately; surgical literature uses non-A non-B for arch involvement without ascending involvement in the appropriate anatomy. Exact entry site, branch involvement and extent are more useful for planning than the label alone. DeBakey I starts in the ascending aorta and extends at least to the arch, usually into the descending aorta. DeBakey II remains in the ascending aorta. DeBakey III originates in the descending aorta, with IIIa confined above the diaphragm and IIIb extending below.
Report lumens, entry, distal extent, rupture and branch perfusion. The beak-shaped angle of the false lumen, internal cobweb strands or mural thrombus can help identify it, but neither relative size nor which lumen supplies a branch is definitive. Dynamic obstruction involves flap or false-lumen pressure reducing flow at a branch origin; static obstruction involves dissection extending into the branch itself, which may stenose or thrombose. A branch arising from the false lumen does not establish malperfusion. Look for ostial compromise and asymmetric organ enhancement and correlate clinically.
For acute type A disease with pericardial fluid, report possible haemopericardium and urgent assessment for tamponade. Pericardial fluid alone does not establish tamponade physiology. Uncomplicated acute type B dissection can start with anti-impulse therapy and structured follow-up. Rupture, malperfusion, expansion or other complications change the pathway; an appropriate complicated descending lesion can require thoracic endovascular aortic repair (TEVAR). An imaging risk feature is one input into aortic team planning. 2024 ESC peripheral arterial and aortic disease guideline, 2024 EACTS/STS aortic guideline and 2026 ESVS descending thoracic guideline.
Size the Aneurysm and Assess the Wall
Use multiplanar reconstructions perpendicular to the centreline on CT, and report the maximum diameter and any relevant additional wall or lumen dimensions. State the calliper convention and modality. When comparing with earlier ultrasound, use consistent planes and edges where possible. A difference between an older ultrasound diameter and a newer CT diameter can reflect technique. At the root, the convention and individual sinus dimensions also matter. A true aneurysm retains a wall, whereas a pseudoaneurysm is a contained breach and can have a narrow connection. Pseudoaneurysm urgency depends on cause and setting.
For an asymptomatic fusiform infrarenal abdominal aortic aneurysm (AAA) managed using the 2024 ESVS guidance, consider the following ultrasound surveillance intervals if consistent with the patient's goals and suitability for future repair:
| Diameter on surveillance ultrasound | Typical interval |
|---|---|
| 30–39 mm | Every three years |
| 40–49 mm in men or 40–44 mm in women | Annually |
| From 50 mm in men or 45 mm in women until considered for repair | Every six months |
Consider elective repair from 55 mm in men and 50 mm in women, integrating anatomy, fitness and patient preferences. These are thresholds for the specified abdominal setting. Unexplained apparent rapid growth should prompt comparable remeasurement and specialist assessment. A symptomatic aneurysm, possible infection or rupture requires urgent review irrespective of size. Thoracic decisions depend on segment, aetiology, body size, growth and operative risk. For example, the ESC 2024 and ESVS 2026 recommendations give different diameter thresholds for an uncomplicated descending thoracic aneurysm. State the guideline and scenario if a question asks for a number. 2024 ESVS abdominal aorto-iliac guideline.
A new extra-aortic haematoma contiguous with the aneurysm, active extravasation or an abnormal posterior contour draping the vertebrae can raise concern for rupture, including a contained leak. An isolated hyperattenuating crescent can represent acute mural bleeding and merits correlation with symptoms, other findings and prior studies. Clinical outcome cohort for the crescent sign. Compare unenhanced and enhanced images before calling active contrast leakage. In suspected rupture, communicate immediately and coordinate the quickest safe imaging and treatment pathway with the emergency vascular team.
New saccular enlargement, disproportionate periaortic inflammation or gas can suggest infection, especially with bacteraemia or fever. Inflammatory aneurysms can show a soft-tissue mantle and ureteric entrapment. In suspected Takayasu arteritis, MRI helps assess both mural change and arterial anatomy. In suspected giant cell arteritis, temporal and axillary ultrasound is first-line where appropriate expertise is available, and MRI or fluorodeoxyglucose PET may assess other vascular territories. Mural enhancement and uptake are interpreted with symptoms, treatment and comparison imaging. EULAR large-vessel vasculitis imaging guidance.
Read the Sac After Endovascular Repair
After endovascular aneurysm repair (EVAR), record device type if known, measure sac diameter on comparable images, check both sealing zones and any component junction, and evaluate graft migration, kinking and branch or limb patency. Early CTA establishes the postoperative baseline. Later modality and interval depend on the repair, seal, endoleak and sac behaviour. Duplex or contrast-enhanced ultrasound can be useful in suitable abdominal follow-up. Use arterial CT images to assess seal and graft, and consider delayed images for slow sac filling. Unenhanced images can help distinguish pre-existing calcification or embolisation material from contrast.
| Endoleak type | Source or observation |
|---|---|
| I | Failed proximal or distal seal. Look for contrast entering the sac at a landing zone. |
| II | Retrograde flow from a branch such as a lumbar artery or inferior mesenteric artery. Assess change in sac size. |
| III | Component separation or a graft fabric defect. Inspect overlaps and look for contrast adjacent to the defect. |
| IV | Early leak related to graft porosity, uncommon with contemporary devices. |
| V | Sac enlargement with no demonstrable endoleak after appropriate evaluation. Look for an occult source before adopting this diagnosis. |
A stable sac with an isolated type II leak can often be followed. A type II pattern with progressive enlargement needs closer evaluation, including a search for an occult type I or III source. For example, a new arterial jet from the proximal landing zone with sac enlargement suggests a type I leak, even if a lumbar branch opacifies later. Report the suspected source and communicate it promptly. Unexpected perigraft gas, fluid or soft-tissue change requires context from the timing of surgery, interval evolution and clinical signs of infection. CIRSE endoleak standards.
A 71-year-old with abrupt interscapular pain has a smooth high-attenuation 9 mm crescent in the descending thoracic aortic wall on unenhanced CT. CTA shows no enhancement in the crescent, no demonstrable dissection flap, and no penetrating contrast-filled crater. Which is the best imaging diagnosis?
Patent false lumen of a classic dissection
Penetrating atherosclerotic ulcer
Acute intramural haematoma involving the descending aorta
Routine chronic mural thrombus in an otherwise uncomplicated aneurysm
A 68-year-old man under vascular follow-up has a stable, asymptomatic 52 mm fusiform infrarenal aneurysm on comparable surveillance ultrasound. Under the 2024 ESVS guideline, what is the typical imaging plan if he is a candidate for later repair?
Ultrasound in six months
Immediate open repair because the diameter exceeds 30 mm
Discharge without surveillance
Ultrasound in five years
After abdominal EVAR, CTA shows a new arterial-phase jet entering the expanding aneurysm sac at the proximal graft attachment. Which interpretation best fits?
Type II endoleak from retrograde lumbar flow
Expected fabric porosity without pressure implication
Endotension with no identifiable contrast leak
Type I endoleak at the proximal seal requiring prompt vascular review