9.1 Valve Types & Functions
Key Takeaways
Use a conventional isolation gate valve fully open or fully closed. Sustained throttling can damage the disc and seats.
Globe valves are common for regulation. Compare flow capacity and pressure loss for the specific trim and valve size.
Ball and butterfly valves commonly move about a quarter turn. Select an isolation or control design and check the seat and service limits.
Check valves limit reverse flow. Match the flow arrow, mounting orientation, and operating conditions to the actual design.
Specify relief devices by service, set pressure and rated capacity. Preserve the approved inlet and discharge paths and verify the nameplate.
Valve Types & Functions
Quick Answer: Start with the required valve duty and the actual service conditions. Gate and most ball valves isolate (full open/closed). Globe and needle valves throttle. Check valves limit reverse flow. Relief/safety valves protect equipment from overpressure. Module 08203 tests whether you know which body style belongs on which service—and what fails when you use the wrong one.
Valves control water, steam, air, chemicals, fuel and other process fluids. Selection starts with the required function and continues with the body, trim, actuator and end connections specified for the line. This section is the selection foundation; installation, operators, and maintenance follow in later sections.
Choosing a valve by duty
| Duty | Meaning | Typical valve families |
|---|---|---|
| Isolation (block) | Fully open for flow; fully closed for shutoff | Gate, ball (full-port), plug (many services), butterfly (many services) |
| Throttling (regulation) | Hold a partial opening to control rate or pressure drop | Globe, needle, some characterized ball/butterfly with control trim |
| Backflow prevention | Permit forward flow and limit reverse flow | Check (swing, lift, dual plate, etc.) |
| Overpressure protection | Respond automatically at the specified set pressure | Relief, safety, safety-relief |
Key Point: Sustained throttling with an isolation valve can concentrate flow at the closure element, erode the seat and compromise shutoff.
Gate valves
Gate valves use a flat or wedge gate (disc) that rises out of the flow path when open. When fully open, the gate clears the bore and pressure drop is low—near a straight piece of pipe for many designs.
Best use: Isolation of lines where you need tight shutoff and low permanent pressure loss when open—headers, equipment isolation, steam mains block valves (as specified).
Not for: Continuous throttling. A partially open conventional isolation gate creates a high-velocity slot. This can erode the disc and seats (wire drawing), cause vibration and impair shutoff.
Practical notes for pipefitters:
- Rising-stem gates show position by stem height; non-rising stems need a position indicator when visibility matters
- Stop and report binding or unexpected torque. Use the specified operating limits and travel indications.
- Follow the model instructions at the end of travel. Some designs have a backseat, which does not establish safe isolation for packing service.
Globe valves
Globe valves force fluid through a change of direction across a seat; the disc moves perpendicular to the seat face. That geometry suits throttling and often produces more pressure loss than a comparably sized full-bore isolation valve. Check the manufacturer’s flow coefficient and operating limits when sizing a valve.
Best use: Flow control, bypass regulation, level or pressure trim where manual adjustment is required, services that need specified shutoff performance as well as regulation (within design limits).
Exam comparison: If the stem asks which valve is preferred for throttling steam or water, globe (or needle for small precise flows) beats gate.
Ball valves
Ball valves use a spherical plug with a port. A typical isolation ball valve rotates about 90° between fully open and closed. Verify the travel for the exact model. A full-port design gives an open flow path with low loss. A reduced port has a smaller opening. Segmented or V-port ball designs, such as Fisher Vee-Ball control valves, can be selected for modulating service.
Best use: Quick isolation, compact automated isolation, many liquid and gas services with appropriate seats (PTFE, reinforced polymers, metal seats for high temperature).
Cautions:
- Use the seat’s pressure-temperature and chemical limits to check suitability for steam, abrasive slurry or other severe service.
- Floating-ball and trunnion designs behave differently under high differential pressure; follow the data sheet
- Not every ball valve is rated as a control valve; throttling can damage seats unless the valve is designed for it
Butterfly valves
Butterfly valves use a disc rotating in the bore—also typically quarter-turn. They are light, compact, and common in large diameters for water, HVAC, and many process services.
Best use: Large-line isolation and, with proper design, some control duties; wafer, lug, and flanged body styles for different install methods.
Cautions: The open disc stays in the bore. Check the seat material and the data sheet for shutoff direction and differential pressure. A suitable lug-type model can have a separate dead-end rating for an approved single-flange installation. A dead-end rating alone does not authorize opening adjacent piping.
Check valves: swing, lift, dual plate
Check valves open when forward differential pressure overcomes the closure force. As flow slows or reverses, gravity, spring force or backpressure closes the disc, depending on design. A check can pass and cannot serve as the personnel isolation for line opening.
| Type | How it works | Typical notes |
|---|---|---|
| Swing check | Disc swings on a hinge. Check flow capacity and minimum flow for stable opening. | Follow the model’s mounting limits. Delayed closure can cause slam. |
| Lift check | Disc lifts off a seat (similar to globe path) | Align the disc guide as specified. Gravity-dependent designs can restrict mounting orientation. |
| Dual-plate / wafer check | Two spring-assisted plates | Compact, normally installed between flanges. Follow the arrow, orientation and plate-clearance requirements. |
Installation rule: Flow arrow on the body must match process flow. Reversed installation may block intended flow or provide ineffective reverse-flow protection. For example, Velan specifies cover-up mounting for certain gravity swing and unsprung T-pattern piston checks. For vertical lines, choose a model explicitly permitted for that direction and mounting.
Plug valves
Plug valves use a cylindrical or tapered plug with a port. Many are quarter-turn isolation valves; lubricated and non-lubricated designs exist for different media (including slurry and corrosive services with proper materials).
Best use: On/off service where a simple robust rotary plug fits the specification—often multiport designs for diverting flow when specified.
Needle valves
Needle valves use a tapered needle-like plug into a small seat for fine throttling on instrument lines, gauge roots, sampling, and small-bore control. Use only within the specified size, capacity and shutoff requirements.
Relief and safety valves (overpressure protection)
Pressure relief valves (PRVs) and safety valves begin their specified opening action at the set pressure to protect vessels, exchangers and piping. Set pressure, pressure at rated relieving capacity and reseating pressure describe different points in operation.
| Term (training view) | Role |
|---|---|
| Relief valve | Typically liquid service; lift generally increases with pressure above the set point |
| Safety valve | Typically compressible fluids (steam/gas); pops open rapidly |
| Safety-relief | Suitable for liquid or compressible-fluid service as approved for the design |
Pipefitter responsibilities (awareness level on many assessments):
- Use the approved orientation and preserve the required inlet and discharge paths. Apply the governing code and approved safeguards if the installation allows an intervening stop valve.
- Protect the device from test pressure as the approved plan directs. Verify removal of temporary gags or test isolation and restoration of the relief path before service. Setting and adjustment belong to the authorized process.
- Support discharge piping so reaction forces and thermal loads do not stress the valve
- Keep inlet and outlet free of debris; verify nameplate set pressure matches the drawing
Matching valve to service (decision table)
| Service need | Prefer | Avoid |
|---|---|---|
| Tight isolation, low open pressure drop | Gate or full-port ball (as specified) | Throttling a gate |
| Manual flow regulation | Globe or designed control valve | Gate left half open |
| Fast quarter-turn isolation | Ball or butterfly | Using a check as a block valve |
| Stop reverse flow only | Check valve correct type/orientation | Check alone for maintenance isolation |
| Fine instrument adjustment | Needle | Oversized globe without trim |
| Overpressure protection | Coded relief/safety valve | Improvised blow-off without engineering |
Materials, ends, and ratings (selection awareness)
Even the right type fails if class, material, and end connection are wrong:
- Pressure and temperature. For a valve made to ASME B16.34, look up the class and pressure-containing material in the applicable edition. Confirm the assembled valve’s published limits, including trim, seat and allowable differential pressure.
- Body and trim materials must suit media (carbon steel, stainless, alloy, bronze, etc.)
- End connections — flanged, threaded, socket weld, butt weld, wafer—must match the pipe spec
- Soft goods (seats, seals, packing) limit temperature and chemical compatibility
Scenario: steam header block vs bypass
A crew installs a gate valve on a steam header isolation point (correct for full open/closed) but uses another gate on a small bypass intended for warm-up throttling. After repeated throttling, the bypass gate passes in the closed position. Inspect the seat for erosion after approved isolation. Select a globe or the specified warm-up control valve sized for steam and the expected differential pressure. The header isolation gate can remain if it meets its separate shutoff, material and rating requirements.
Putting Module 08203 selection together
- Decide isolation, throttle, check, or relief first.
- Pick body style that matches that duty.
- Confirm orientation, pressure class, materials, and ends.
- Never throttle with a pure isolation gate; never treat a check as a maintenance block.
- Treat relief devices as safety-critical—set points and paths are not field “adjustments.”
A pipefitter needs a valve for continuous throttling of process water flow. Which type is the best match among standard manual valves?
Globe valve sized and installed for regulation duty
Gate valve left at mid-stroke for years of service
Swing check valve partially blocked with a wedge
Relief valve with the set spring backed off by hand
What is the primary service purpose of a check valve?
Fine instrument metering equal to a needle valve
Replacing a blind flange for positive isolation during hot work
Preventing reverse flow while allowing forward flow
Automatically holding a precise throttled intermediate position
Why is a conventional isolation gate valve a poor choice for continuous partial-open flow control?
Gate valves always have higher pressure drop than globe valves when fully open
Partial opening creates high-velocity erosion (wire drawing), vibration, and seat damage
Gate valves cannot be operated with handwheels
Gate valves are quarter-turn devices and cannot stop mid-travel
Ball and butterfly valves are commonly described as which kind of operating style?
Multi-turn rising-stem only with no rotary motion
Automatic only—never available with manual levers
Lift-check style with a hinged disc and no stem
Quarter-turn (approximately 90°) from fully open to fully closed