Safety
12%of exam
Math
12%of exam
Pipefitting Fundamentals
12%of exam
Cutting
8%of exam
Fabrication
16%of exam
Construction Drawings
10.4%of exam
Rigging
6.4%of exam
Valves, Hangers, and Supports
11.2%of exam
Pipefitting Specialties
12%of exam
Quick Facts
- Assessment
- Industrial Pipefitter PFT08_03
- Level
- Journey-level knowledge assessment
- Written items
- 125
- Time and format
- 3 hours, closed book
- Minimum passing score
- 75
- Allowed reference
- The Pipefitters Blue Book
- Allowed calculator
- Non-programmable, non-printing
- Calculator types
- Basic, scientific, or pipe-specific
- Other study materials
- No extra notes or books
- Full craft certification
- Knowledge assessment + performance verification
- Curriculum
- Pipefitting, 4th edition
- Blueprint revision
- November 2024
Hydrostatic vs Pneumatic
Hydrostatic
- Liquid test medium
- Vent trapped air during fill
Pneumatic
- Gas test medium
- Higher stored energy risk
Test to the approved plan
Safety Checks
- Portable ladder has damaged rung→Withdraw it from service
- Shift starts on scaffold→Competent person inspects
- Excavation exposed to rain→Competent person reinspects
- Approved hydro test filling→Vent trapped air(At high points)
- Liquid medium unsuitable→Use approved test plan(Pneumatic needs added controls)
Access and Excavations
- Typical leaning ladder
- Base setback ≈ ¼ working length
- Damaged portable ladder
- Mark and withdraw from service
- Scaffold inspection
- Competent person before each shift
- Before excavating
- Determine estimated utility locations
- Trench after rainstorm
- Competent person reinspects
- Shoring
- Supports excavation walls
- Shielding
- Protects workers within shield
- Sloping
- Cuts trench walls back
Pressure Test Setup
- Test boundary
- Defines isolated test segment
- Hydrostatic test
- Uses liquid, usually water
- Pneumatic test
- Uses compressed gas
- High-point vent during hydro fill
- Releases trapped air
- Test pressure and duration
- Use governing code and approved plan
- Test gauge
- Check calibration and range
Set, Roll, Then Travel
Square both shifts, root, then divide by sine.
Offset Calculator
- Offset stays in one plane→Use perpendicular offset directly
- Line shifts vertically and sideways→√(set² + roll²)(Find true offset first)
- Given travel angle and offset→Offset ÷ sin θ(Use true offset)
- Need run along original axis→Offset ÷ tan θ(Use true offset)
- Equal 45° offset fittings→True offset × 1.414(Center-to-center travel)
Offset Geometry
- True rolling offset
- √(set² + roll²)
- Center-to-center travel
- True offset ÷ sin θ
- Run along original axis
- True offset ÷ tan θ
- 22.5° travel multiplier
- ≈ 2.613 × true offset
- 30° travel multiplier
- 2 × true offset
- 45° travel multiplier
- ≈ 1.414 × true offset
- 60° travel multiplier
- ≈ 1.155 × true offset
- Set 6″, roll 8″
- True offset = 10 in
- 10 in offset at 45°
- Travel ≈ 14.14 in
Layout Formulas
- Offset angle θ
- Between travel and original run
- Rise or fall
- Horizontal run × slope ratio
- Pipe outside circumference
- π × outside diameter
- Inside diameter (ID)
- OD − 2 × wall thickness
- Degrees on calculator
- Use degree mode
NPS vs Schedule
NPS
- Nominal size designation
- Look up actual OD
Schedule
- Wall-thickness series
- Look up wall by NPS
Specify both size and schedule
Hand and Power Tools
- Pipe wrench
- Turns round threaded pipe
- Strap wrench
- Grips polished pipe without teeth
- Pipe vise
- Holds pipe during fabrication
- Reamer
- Removes internal cut burr
- Threading die
- Cuts external pipe threads
- Pipe stand
- Supports stock during fabrication
Pipe Dimensions and Standards
- NPS
- Nominal Pipe Size
- Pipe schedule
- Wall-thickness series by size
- OD
- Measured outside diameter
- Same NPS, thicker wall
- Smaller inside bore
- ASME B31.3
- Process piping code
- WPS
- Welding procedure specification
Oxyfuel Cutting
- Preheat flame
- Raises steel to ignition temperature
- Cutting oxygen
- Oxidizes steel and ejects slag
- Ordinary oxyfuel cutting
- Suitable for carbon steel
- Regulator
- Controls gas delivery pressure
- Kerf
- Width of material removed
- Oxygen equipment
- Keep free of oil and grease
Field Routing
- Field cut
- Verify actual tie-in dimensions
- Routing check
- Confirm clearances and support locations
- Vessel trim
- Piping and fittings at vessel
- Prepared weld bevel
- Check approved joint detail
Butt Weld vs Socket Weld
Butt weld
- Opposing ends align
- Check specified root opening
Socket weld
- Pipe enters socket
- Check specified back-off gap
Follow the approved joint detail
Fit-Up Decisions
- Given center distance between fittings→Subtract both center-to-face dimensions
- Given clear faces, butt welds→Subtract both specified root gaps
- Given clear faces, threaded joints→Add both specified thread engagements
- Socket weld fit-up→Check insertion and specified gap
- Bevel angle or root gap→Check approved weld procedure(Use applicable joint detail)
Joint Types
- Butt weld
- Joins aligned pipe ends
- Socket weld
- Pipe inserts into fitting recess
- Socket weld fillet
- Around socket mouth
- Socket weld fit-up
- Leave specified insertion gap
- NPT
- Tapered American pipe thread
- Thread engagement
- Length inserted into threaded fitting
- Thread sealant
- Match fluid and service conditions
Takeouts and Fit-Up
- Center-to-face dimension
- Fitting centerline to end face
- Clear face-to-face gap
- Center distance − both center-to-face dimensions
- Butt-weld cut length
- Face distance minus both root gaps
- Threaded cut length
- Face distance plus both engagements
- Takeout lookup
- Use exact fitting dimensions
- Hi-lo
- Internal offset at joint
- Miter turn
- Angled cuts form the bend
- Saddle layout
- Template matches intersecting pipe contour
Line, Legend, Dimensions
Trace the line, read the legend, trust dimensions.
P&ID vs Isometric
P&ID
- Process connections and flow
- Instrument tags and signals
Isometric
- Spatial pipe routing
- Fabrication dimensions and elevations
Trace flows on the P&ID
Drawing Picker
- Trace process flow and controls→P&ID
- Locate equipment in plant→General arrangement
- Find elevations and offsets→Piping isometric
- Fabricate one numbered assembly→Spool drawing
- Count fittings for spool→Bill of materials
Pipe Drawings
- P&ID
- Piping and instrumentation diagram
- Instrument signal line
- Shows control or measurement connection
- General arrangement
- Shows equipment placement and routing
- Piping isometric
- Shows spatial routing and dimensions
- Spool drawing
- Details one fabricated pipe assembly
- Bill of materials
- Lists components and quantities
- Elevation
- Height relative to project datum
- Continuation reference
- Follow line onto another sheet
Vertical vs Basket Hitch
Vertical
- Single straight sling leg
- Use vertical hitch rating
Basket
- Both sling ends support load
- Use rated basket configuration
Read hitch and angle rating
Lift Checks
- Sling identification missing→Remove equipment from service
- Sling angle becomes flatter→Recheck rated configuration
- Sharp edge contacts sling→Use suitable edge protection
- Emergency stop signal received→Stop the lift
Hitches and Sling Loads
- Vertical hitch
- Single straight sling connection
- Basket hitch
- Sling cradles load from underneath
- Choker hitch
- Sling cinches around load
- Flatter sling angle
- Higher leg tension, same load
- Sling tag
- Check rated configurations
- Defective rigging
- Remove from service
- Sling over sharp edge
- Protect sling from edge damage
- Emergency stop
- Obey regardless of signaler
Isolate, Regulate, Check
Gate isolates, globe regulates, check blocks backflow.
Gate vs Globe
Gate
- Typical isolation duty
- Normally fully open or shut
Globe
- Typical regulating duty
- Suitable trim for throttling
Choose by duty and service
Valve and Support Picker
- Typical line isolation needed→Gate valve(Check service specification)
- Typical throttling needed→Globe valve(Check service specification)
- Backflow prevention needed→Check valve(Verify flow arrow)
- Automatic overpressure protection needed→Specified relief device
- Limit sideways pipe drift→Specified guide
- Support pipe through vertical travel→Specified spring hanger
Valve Functions
- Gate valve
- Typical on-off isolation
- Globe valve
- Typical throttling service
- Check valve
- Closes against reverse flow
- Check valve flow arrow
- Matches intended flow direction
- Relief valve
- Opens at set pressure
Guide vs Anchor
Guide
- Permits designed axial travel
- Limits lateral movement
Anchor
- Fixes pipe at design point
- Transfers restraint forces to structure
Check the support detail
Support and Movement
- Clevis hanger
- Suspends pipe from structure
- Rest support
- Carries downward pipe load
- Guide
- Restrains lateral movement
- Anchor
- Restrains pipe at fixed point
- Spring hanger
- Carries load during vertical travel
- Pump nozzle
- Observe allowable piping loads
Grooves Grip, Gasket Seals
Housing grips grooves, gasket seals the joint.
Soldering vs Brazing
Soldering
- Filler liquidus below 450°C
- Copper base metal stays solid
Brazing
- Filler liquidus above 450°C
- Copper base metal stays solid
Compare filler metal liquidus
In-Line Devices
- Steam trap
- Discharges condensate, limits steam loss
- Drip leg
- Collects condensate for drainage
- Strainer
- Screens debris from flow
- Thermowell
- Protects temperature sensor
- Expansion joint
- Accommodates specified pipe movement
- Desuperheater
- Lowers superheated steam temperature
Installation and Special Joints
- Buried pipe bedding
- Provides uniform support
- Haunching
- Supports lower sides of pipe
- Flanged joint gasket
- Seals between mating faces
- Grooved coupling
- Housing engages grooves, gasket seals
- Copper soldered joint
- Lower-temperature capillary filler
- Copper brazed joint
- Higher-temperature capillary filler
Common Traps
Excavation protection
Shoring supports trench walls ≠ Shielding shelters workers
Offset geometry
True offset across runs ≠ Travel between fitting centers
Dimensional labels
Nominal pipe size designation ≠ Measured outside diameter
Cut layout
Kerf width removed ≠ Bevel angle created
Fit-up dimensions
Fitting center-to-face dimension ≠ Thread engagement into fitting
Drawing scale
Isometric drawn appearance ≠ Verified written fabrication dimension
Rigging capacity
Sling tension per leg ≠ Total load weight
Steam line devices
Steam trap discharges condensate ≠ Strainer catches debris
Last Minute
- 1.Fabrication carries 20 written items
- 2.Blue Book allowed during assessment
- 3.Hydro test filling vents air
- 4.Roll and set combine perpendicularly
- 5.45° travel ≈ 1.414× true offset
- 6.Size and schedule determine wall thickness
- 7.Allow for both butt-weld root gaps
- 8.P&ID traces flow and instrumentation
- 9.Flatter sling angles raise leg tension
- 10.Gate isolates, globe throttles
- 11.Guides allow designed axial movement
- 12.Steam traps discharge condensate