12.3 In-Line Specialties

Key Takeaways

  • Match the specialty tag, drawing and nameplate. Verify the actual model, pressure–temperature limits, flow direction and required orientation.

  • Protect sealing faces, sensing ports and sensitive components during storage and lifting. Check the approved isolation and discharge path before opening a device.

  • Steam equipment needs its specified drainage path. The required strainer orientation depends on the model and fluid.

  • Structural snubbers and pressure-gauge snubbers serve different functions. Ball joints and bellows use their designed movement and restraint geometry.

  • Use the specified installation details for the relief device and measuring instrument. Sensing location, orientation and accessories affect performance.

Last updated: November 2026

In-Line Specialties

Quick Answer: Module 08405 covers recognizing, handling, and installing specialty devices. Before installation, match the device to its tag and service. Check the manufacturer's installation instructions for flow direction, orientation, pressure and temperature limits, supports, and access.

Receiving and installing specialties safely

  1. Match the P&ID tag and installation detail to the nameplate. Verify the body, trim or element, connection and rating for the service and any planned pressure test.
  2. Keep equipment clean and protected until installation. Leave caps and flange protectors in place during storage. Handle bellows by approved lift points, protect meter linings, and keep rupture discs in their packaging until assembly.
  3. Trace process flow and identify ports, gauges, pressure taps and alarms before connecting tubing. If the marked direction or port assignment conflicts with the drawing, stop and resolve the installation before assembly.
  4. Verify the designed orientation, installed position and maintenance clearance. Identify temporary packaging and shipping devices separately from permanent restraints.
  5. Before opening equipment in service, follow the applicable energy isolation procedure. Verify pressure release and safe drainage, and account for trapped pressure and stored mechanical energy.

Purpose and orientation catalog

DevicePurpose (field language)Orientation / install notes
SnubberStructural snubbers restrain rapid pipe motion. Pressure-gauge snubbers damp pressure pulsation at the instrument.Check the structural device’s stroke and attachments, or the gauge accessory’s service rating and process connection.
Ball jointAccommodates angular motion within the designed piping geometryCheck assembled angle, clearances, supports and restraint; verify joint-specific limits
Bleed ringRing between flanges with a side port for venting, draining or another specified connectionVerify the sealing interface on each side, tap access, and safe discharge routing
Drip legCollects liquid at designed drainage points in steam or air systemsCheck the specified pocket size, drain path, and trap or drain arrangement
Steam trapDischarges condensate while limiting live-steam loss. Air handling varies by design.Body orientation per type (float, inverted bucket, thermostatic, thermodynamic); inlet/outlet correct; strainer upstream often required
Expansion jointAccommodates the directions and magnitude of movement allowed by its designVerify guides, anchors, installed position, and the status of temporary and permanent hardware
FilterRemoves specified contamination using a selected elementMatch element and orientation. Confirm drain, service clearance and differential-pressure checks where specified.
Strainer (Y, basket, cone/temp)Captures debris to protect equipmentScreen chamber orientation for drainage and cleaning; blowdown connection accessible; temporary start-up strainers tracked for removal
FlowmeterMeasures flow (orifice, mag, turbine, ultrasonic, etc.)Upstream/downstream straight runs; correct flow arrow; process reference on magmeters where specified; keep gasket clear of the bore
Level deviceIndicates or transmits liquid levelNozzle orientation, bridle elevations, and block valves per detail; freeze protection where needed
Flow / pressure switchChanges switching state at a specified flow or pressure conditionProcess connection above/below centerline as designed; correct set-point hardware left for I&C; do not plug sensing ports
Rupture discNonreclosing overpressure protectionMatch disc and holder. Verify marked flow direction, burst conditions, and specified assembly loads.
ThermowellProtects temperature sensor from processImmersion length, wake-frequency design awareness, thread/flange engagement; do not cut wells short in the field without engineering
Spray desuperheaterInjects cooling water to reduce the temperature of superheated steamCheck nozzle direction, water quality, straight run and sensor locations against the certified drawing.

Snubbers and ball joints

Hydraulic or mechanical structural snubbers allow slow movement and restrain specified rapid or transient movement. Check the installed position against the required hot and cold travel and inspect attachment points and clearance. A pressure-gauge snubber limits the pulsations reaching a measuring instrument. For example, WIKA AC 09.03 describes a 910.12 version with an adjustable flow restriction. Select the accessory for the medium and required instrument response.

Ball joints can take angular motion at designated offsets within their limits. Hyspan Barco Type N Style I uses angular flex in an offset arrangement. Follow its instructions for alignment and supports and leave the joint retainer intact. A joint's allowable motion is part of the piping design and does not authorize loosening or using the joint as a union. Some packed designs have different maintenance provisions.

Bleed rings and drip legs

A bleed ring is a tapped ring between two flanges. The side port can connect to a specified vent, drain, instrument or sampling line. Verify the ring facing and rating, bolting length and a compatible seal at each interface. Position the connection so authorized workers can reach it and operate any valve safely. Confirm a clear path from the bore into the port and route the outlet as designed. A bleed ring alone cannot establish isolation.

A drip leg collects condensate at a designated low point or drain location. Use the detailed pocket geometry and drain or trap assembly. Verify the safe discharge path and provide the access needed to clear debris. Section 11.2 covers steam-main drainage and trap differential pressure.

Steam traps

Steam traps are automatic condensate discharge devices. Types behave differently:

Type (awareness)Typical trait
Float & thermostaticFloat-controlled condensate discharge with a separate thermostatic vent
Inverted bucketCycles with changes in buoyancy and uses a water seal. Air vents slowly in many designs.
ThermostaticResponds to temperature. Check the amount of upstream cooling the installation permits.
Thermodynamic (disc)Compact; cyclic; sensitive to dirt and some backpressure conditions

Install rules:

  • Correct inlet vs outlet; many traps will not operate reversed
  • Keep the body in the manufacturer’s allowed attitude (horizontal, vertical discharge up/down)
  • Provide unions or flanges and isolation valves for maintenance when the detail shows them
  • Install strainers and check valves only as designed (check valves can affect some trap types)
  • Slope lines to drain toward the trap; avoid lifting condensate without adequate design (lift fittings, pump traps)

When a trap fails to drain, check installation, load, obstruction and the available pressure difference. Check the expected trap cycle using the approved observations. A hot outlet can contain flash steam and does not establish a live-steam leak. Compare inlet and outlet temperatures with ultrasonic readings when specified. After authorized isolation, depressurization and cool-down, check strainers and clear debris or service the trap as its instructions require. Repeat the checks after reinstatement.

Expansion joints

Metal bellows, rubber expansion joints and slip joints accommodate specific movements. Confirm the type, movement, leakage and restraint requirements before installation.

  1. Use the design’s anchors, guides and permanent hardware. An unrestrained axial bellows depends on the main anchors for pressure thrust.
  2. Identify shipping bars separately from permanent restraint hardware. For example, U.S. Bellows requires shipping-bar removal after installation and before pressure testing the completed system.
  3. Verify the installed length and position along with the specified cold offset, if any. Have fit-up outside the approved limits corrected.
  4. Use the design and manufacturer instructions to distinguish limit, control, and thrust-restraint hardware and to set any specified gaps.
  5. Provide the insulation and protective cover shown in the design while preserving the required travel and access.

Filters, strainers, meters, and switches

Filters and strainers. Verify flow direction, element or screen, and access for service. For example, Parker's 3F101 air-filter instructions place the bowl vertically with its drain at the bottom. For the Spirax Sarco Fig 34 Y-strainer in horizontal pipe, the pocket lies to the side in steam or gas and points down in liquid service. An Eaton Model 73 basket strainer requires access to remove the basket and uses differential pressure to monitor loading. Track temporary strainers in the startup plan so they are inspected or removed at the specified stage. Safely isolate and depressurize any housing before opening it.

Flowmeters. Use the model and upstream fittings to determine the required straight runs. For the Rosemount 1495 paddle-style orifice plate, identify the marked inlet, center the specified plate and preserve the bore and pressure-tap paths. An orifice produces differential pressure that varies approximately with the square of volumetric flow for fixed geometry, fluid density and flow coefficient. If differential pressure increases from 10 to 40 in. of water under those assumptions, the indicated flow doubles because the square root of 40 ÷ 10 is 2. A magnetic meter such as the Rosemount 8700 needs the specified full-pipe orientation and process reference for its piping material. Follow the electrical grounding instructions as well.

Level and switch hookups. Verify which tap goes to each side of a differential-pressure instrument, its elevation, and the specified reference leg. For example, the liquid in a Rosemount 3051 wet leg imposes head on the low side, which the ranged measurement must account for. Follow the hookup for bridle orientation, isolation, vent and drain locations. A flow or pressure switch changes its output at a specified condition. Provide the correct rated connection, support and service access, and have authorized personnel set or function-test it. Verify the intended alarm or trip on return to service where required.

Rupture discs, thermowells, and desuperheaters

Rupture discs provide a nonreclosing opening for overpressure protection. Match the disc and holder identification, marked burst pressure and temperature, and intended service. Use the manufacturer's direction marks on both disc and holder, since designs orient their domes differently. Fike's insert-holder instructions require matching the flow arrows and using prescribed bolting for the holder configuration. Protect the seats and disc from scratches and deformation. Replace an activated disc and restore the approved relief path before pressurizing.

Thermowells form a process barrier around a temperature sensor. An intact, properly installed well can allow withdrawal of the sensor while the well stays in service, if the procedure permits. Treat removal of the well itself as opening the process boundary. Install the specified insertion length and connection, and check that the well clears the opposite wall. ASME PTC 19.3 TW-2016 (R2025) covers thermowells machined from bar stock within its scope. Use the approved design for flow-induced vibration and preserve the evaluated geometry.

Spray desuperheaters cool superheated steam by injecting water that evaporates in the steam flow. For example, the Fisher DFA instructions direct installers to use the certified drawing for the unobstructed vaporization length and downstream temperature sensor location. Check the water connection, approved water quality and specified strainer. Premature turns or a misplaced sensor can disrupt vaporization or temperature control. Follow the design for supports and drainage.

Scenario: Y-strainer and steam trap reversed

A horizontal steam branch experiences water hammer during warm-up. Operations stops the warm-up, then authorized workers isolate the branch, release trapped pressure and verify it is safe to inspect. They find a Fig 34 Y-strainer with its pocket pointing down and a disc trap turned against the marked flow direction. Correct the strainer and trap to the documented orientations, verify the drip pocket and return path, and inspect the equipment for damage. Complete the required checks before the approved restart. A horizontal liquid line using the same strainer would place the pocket down.

Putting Module 08405 together

  1. Identify every specialty from tag, P&ID, and nameplate before makeup.
  2. Check flow arrows and orientation where required by the selected device.
  3. Provide supports, anchors, guides, and maintenance access the device needs.
  4. Treat rupture discs and protective devices as safety-critical hardware.
  5. Coordinate straight runs and elevations for meters and level taps—geometry is part of the measurement.

At turnover, verify the operating lineup, including temporary devices and any protective or measuring function affected by the work.

Test Your Knowledge

What is the primary process purpose of a steam trap?

A

To discharge condensate while restricting the loss of live steam.

B

To regulate steam supply pressure as downstream demand changes.

C

To lift condensate even when the return pressure exceeds the available inlet pressure.

D

To measure steam flow by sensing differential pressure across an orifice.

Test Your Knowledge

The flow arrow on a rupture disc tag opposes the arrow on its holder. What should the installer do?

A

Turn the complete assembly so the disc arrow faces upstream and leave the holder as supplied.

B

Stop and use the matching disc and holder instructions to verify both arrows and the assembly.

C

Keep the assembled components in place if the flange bolt holes align.

D

Increase the flange load to compensate for the disc direction.

Test Your Knowledge

What should the crew verify before testing a newly installed metal bellows joint?

A

Use the stroke of the bellows to pull the adjacent pipe to its new position.

B

Keep the shipping bars so they can serve as the operating thrust anchors.

C

Verify the installed position, anchors and guides, and handle shipping aids as the manufacturer specifies while keeping permanent restraints in service.

D

Remove all bars and rods because the test pressure must act on an unrestricted bellows.

Test Your Knowledge

At an approved bleed-ring installation, what should the pipefitter check before the joint is placed in service?

A

The outlet is accessible even if the internal passage is sealed off.

B

The ring can drain against the adjacent valve without verifying how the line is isolated.

C

The ring can share one gasket between its two separate flange interfaces.

D

The tap communicates with the bore, its connection is accessible and routed as specified, and both interfaces have the specified seals.