3.1 Atomic Structure, Electromagnetic Spectrum & Radiation Units

Key Takeaways

  • Electron binding energy is highest in the innermost K-shell and increases rapidly with atomic number Z (for example, 69.5 keV in tungsten Z = 74 vs 33.2 keV in iodine Z = 53)

  • The energy ranges of diagnostic X-rays and nuclear gamma rays overlap. Their names describe different production mechanisms.

  • Photon energy varies inversely with wavelength according to E(keV) = 1.24 / lambda(nm), and beam intensity follows the inverse-square law I1 / I2 = (d2 / d1)^2

  • SI units map directly to traditional units: 1 Gy = 100 rad (absorbed dose), 1 Sv = 100 rem (equivalent/effective dose), 1 R = 2.58 x 10^-4 C/kg (exposure), and 1 Ci = 3.7 x 10^10 Bq (activity)

  • AERB Directive 01/2011 sets 20 mSv per year averaged over a sliding five-year period for occupational effective dose, with 30 mSv in any year, and 1 mSv per year for the public.

Last updated: November 2026

Atomic Structure and Electron Binding Energy

The Bohr model introduces the atom as a dense, positively charged nucleus surrounded by electrons in quantized shells. Shell labels K,L,M,N,O,PK, L, M, N, O, P and QQ run from the first shell outward. Quantum orbitals describe electron states within those shells. The nucleus holds nucleons: protons (+1+1 charge) and neutrons (00 charge). Two numbers define every nuclide (ZAX^A_Z X):

  • Atomic number (ZZ): Number of protons in the nucleus, which uniquely identifies the element (carbon Z=6Z = 6, iodine Z=53Z = 53, tungsten Z=74Z = 74, lead Z=82Z = 82) and equals the orbital electron count in a neutral atom.
  • Mass number (AA): Total protons plus neutrons (A=Z+NA = Z + N). Nuclides with the same ZZ are isotopes (e.g., 127I^{127}\text{I}, 131I^{131}\text{I}); same NN are isotones; same AA are isobars; and same Z,AZ, A in different energy states are isomers (e.g., 99mTc^{99\text{m}}\text{Tc}).

Shells follow principal quantum number nn (K=1,L=2,M=3,N=4K=1, L=2, M=3, N=4) with maximum capacity 2n22n^2 (2,8,18,322, 8, 18, 32). These capacities count the available states across all subshells at a given nn. Electron binding energy (EbE_b) is the work required to remove an electron completely from its shell:

  1. Inner shells bind tighter: Eb,K>Eb,L>Eb,ME_{b,K} > E_{b,L} > E_{b,M} in a given atom. Inner electrons generally experience a stronger nuclear attraction with less screening.
  2. K-shell binding increases with ZZ: The larger nuclear charge increases the binding of K-shell electrons. KK-shell EbE_b rises from 0.28 keV0.28\text{ keV} in carbon (Z=6Z=6) and 4.0 keV4.0\text{ keV} in calcium (Z=20Z=20) to 33.2 keV33.2\text{ keV} in iodine (Z=53Z=53), 37.4 keV37.4\text{ keV} in barium (Z=56Z=56), and 69.5 keV69.5\text{ keV} in tungsten (Z=74Z=74).

Excitation raises a bound electron to an allowed higher-energy state. Ionisation occurs when an electron receives enough energy to escape, leaving a positive ion and a free electron. The mean energy expended per ion pair when secondary electrons slow down in dry air is about 33.97 eV33.97\text{ eV}. This includes energy lost to excitation and other processes in addition to ionisation.


The Electromagnetic Spectrum and Wave-Photon Equations

The electromagnetic (EM) spectrum spans radio waves, microwaves, infrared, visible light, ultraviolet, X-rays, and gamma rays. Electromagnetic waves propagate in vacuum at c≈3.0×108 m/sc \approx 3.0 \times 10^8\text{ m/s}. Their quanta, photons, have zero rest mass and no electric charge.

Diagnostic X-rays are produced by extranuclear processes such as electron deceleration and electronic transitions. Nuclear gamma rays are emitted in nuclear transitions. Photon energies overlap, so for a photon of a given energy the interaction probabilities in a specified material follow the same interaction physics. Positron annihilation is a separate production mechanism for the 511 keV photons used in PET.

Frequency (ff), wavelength (λ\lambda), and photon energy (EE) obey:

c=fλandE=hf=hcλc = f\lambda \qquad \text{and} \qquad E = hf = \frac{hc}{\lambda}

where Planck's constant h=6.626×10−34 J⋅sh = 6.626 \times 10^{-34}\text{ J}\cdot\text{s}. Multiplying hchc gives the practical diagnostic conversion:

E (keV)=1.24λ (nm)E\,(\text{keV}) = \frac{1.24}{\lambda\,(\text{nm})}

Worked Photon Calculation: For a 62 keV62\text{ keV} X-ray photon, find λ\lambda and ff:

λ=1.2462=0.02 nm=2.0×10−11 m,f=3.0×1082.0×10−11=1.5×1019 Hz\lambda = \frac{1.24}{62} = 0.02\text{ nm} = 2.0 \times 10^{-11}\text{ m}, \qquad f = \frac{3.0 \times 10^8}{2.0 \times 10^{-11}} = 1.5 \times 10^{19}\text{ Hz}

Higher photon energy always means shorter wavelength and higher frequency.


The Inverse-Square Law

For the primary beam from a source approximated as a point, the illuminated area at fixed solid angle grows in proportion to d2d^2. Within the same beam direction, intensity thus varies inversely with distance squared when attenuation and scatter are negligible:

I1I2=(d2d1)2\frac{I_1}{I_2} = \left(\frac{d_2}{d_1}\right)^2

Worked Distance Calculation: In an in-air primary-beam measurement without an intervening patient or phantom, suppose the air kerma rate is 3.6 mGy/min3.6\text{ mGy/min} at d1=100 cmd_1 = 100\text{ cm}. At the same output and on the same beam axis at d2=300 cmd_2 = 300\text{ cm}, the ideal estimate is:

I2=3.6×(100300)2=3.6×19=0.4 mGy/minI_2 = 3.6 \times \left(\frac{100}{300}\right)^2 = 3.6 \times \frac{1}{9} = 0.4\text{ mGy/min}

Tripling the distance gives one-ninth of the initial primary-beam air kerma rate, about an 89% drop. Around a patient, scatter and shielding also affect staff dose.


SI vs. Traditional Radiation Quantities and Units

Use SI units for calculations and recognise the corresponding traditional units. First identify which quantity is given. Absorbed dose and kerma both use gray, even though they describe different energy quantities.

QuantityDefinitionSI UnitTraditional UnitExact Conversion
Exposure (XX)Charge of ions of one sign produced in dry air per unit mass under the exposure definition for photonsC/kg\text{C/kg}Roentgen (R\text{R})1 R=2.58×10−4 C/kg1\text{ R} = 2.58 \times 10^{-4}\text{ C/kg}
Kerma (KK)Initial kinetic energy transferred by indirectly ionising radiation to charged particles per unit massGray (Gy=1 J/kg\text{Gy} = 1\text{ J/kg})rad1 Gy=100 rad1\text{ Gy} = 100\text{ rad}
Absorbed Dose (DD)Mean energy deposited per unit mass of matterGray (Gy=1 J/kg\text{Gy} = 1\text{ J/kg})rad1 Gy=100 rad1\text{ Gy} = 100\text{ rad} (1 cGy=1 rad1\text{ cGy} = 1\text{ rad})
Equivalent Dose (HTH_T)Organ dose weighted by radiation factor (wRw_R)Sievert (Sv\text{Sv})rem1 Sv=100 rem1\text{ Sv} = 100\text{ rem}
Effective Dose (EE)Tissue-weighted sum of organ equivalent doses (∑wTHT\sum w_T H_T)Sievert (Sv\text{Sv})rem1 Sv=100 rem1\text{ Sv} = 100\text{ rem}
Radioactivity (AA)Expected nuclear transformations per unit timeBecquerel (Bq=1 dps\text{Bq} = 1\text{ dps})Curie (Ci\text{Ci})1 Ci=3.7×1010 Bq1\text{ Ci} = 3.7 \times 10^{10}\text{ Bq}

Radiation and Tissue Weighting Factors

Equivalent dose is HT=∑RwRDT,RH_T = \sum_R w_R D_{T,R}, where DT,RD_{T,R} is the mean absorbed dose in tissue TT from radiation type RR. Diagnostic photons and electrons have wR=1w_R = 1, so for these radiations 1 Gy mean absorbed dose to an organ gives 1 Sv equivalent dose to that organ. Alpha particles have wR=20w_R = 20 and protons have wR=2w_R = 2 under ICRP 103. Effective dose applies tissue weights to organ equivalent doses in the reference-person framework using E=∑TwTHTE = \sum_T w_T H_T.

ICRP 103 gives wT=0.12w_T = 0.12 each to red bone marrow, colon, lung, stomach and breast, and 0.12 to the remainder group as a whole. The gonads receive 0.08. Bladder, oesophagus, liver and thyroid each receive 0.04. Bone surface, brain, salivary glands and skin each receive 0.01. The weights sum to 1. Effective dose is a protection quantity based on reference populations. An individual risk assessment uses organ doses and appropriate risk models.

AERB Directive 01/2011 sets an occupational effective dose limit of 20 mSv per year averaged over a sliding five-year period, with at most 30 mSv in any year. The public effective dose limit is 1 mSv per year. These limits concern occupational and public exposure, respectively. Medical exposure of a patient is managed through justification and optimisation.

Test Your Knowledge

Which property distinguishes a 140 keV photon generated by an X-ray tube from a 140 keV photon emitted in a nuclear gamma transition?

A

Velocity in a vacuum

B

Electrical charge and rest mass

C

The production mechanism, outside the nucleus versus a transition of the nucleus

D

Interaction probability in soft tissue

Test Your Knowledge

At a fixed X-ray output, an in-air primary-beam measurement is 1.6 mGy/min at 100 cm from the focus. Assuming negligible scatter and air attenuation, what is the estimate at 200 cm on the same beam axis?

A

0.4 mGy/min

B

0.8 mGy/min

C

3.2 mGy/min

D

6.4 mGy/min

Test Your Knowledge
Matching

Match each radiation quantity with its SI unit and traditional conversion.

Match each item on the left with the correct item on the right

1

Exposure (X)

2

Absorbed Dose (D)

3

Effective Dose (E)

4

Activity (A)

Sections you finish are checked off in the contents.