11.1 Patient Care, Vital Signs, Infection Control & Biomedical Waste
Key Takeaways
Verify the person with two patient identifiers and confirm the planned examination and side. Screen for possible pregnancy when the requested examination could expose an embryo or fetus.
Assess vital-sign trends and symptoms together. A pulse oximeter estimates saturation, and an apparently reassuring reading can miss clinical deterioration.
Apply standard precautions to every patient. Add airborne precautions for infectious pulmonary tuberculosis, including a properly fitted particulate respirator.
Keep a chest drain bottle upright below chest level and a urinary bag below bladder level during transport. Communicate responsibilities for oxygen and lines before moving the patient.
Schedule I groups soiled dressings in yellow, contaminated recyclable tubing in red, sharps in white translucent, and contaminated non-cytotoxic glass and metallic implants in blue-marked containers.
Confirm the Patient and Examination
Ask the patient to state two identifiers, such as full name plus either date of birth or the hospital identifier. Match them to the request and to the wristband if used. A bed number identifies a location. If the request, wristband or patient account conflicts, resolve the discrepancy before exposing. Confirm the relevant clinical indication, body part and side, and use the correct anatomical marker.
For an abdominal or pelvic X-ray in a patient who could be pregnant, ask about possible pregnancy and follow the department's screening process. The date of the last menstrual period may be relevant. Escalate uncertainty to the responsible practitioner. Explain the exam, positioning and breath-hold cues in accessible language, and check whether the patient needs an interpreter or assistance.
Assess Vital Signs and Escalate Changes
Follow the monitoring plan for contrast, sedation, intervention or an unwell patient. Record actual measurements and compare them with the baseline. A healthy resting adult's examples are reference values; symptoms and changes from that patient's baseline inform escalation.
| Observation | What to check |
|---|---|
| Pulse | Rate, rhythm and strength. A resting adult pulse is commonly 60–100 beats per minute. |
| Breathing | Rate, depth, effort and ability to speak. Increased work of breathing can be significant even before the monitor changes. |
| Blood pressure | Systolic and diastolic values and the trend. A sudden fall with faintness or altered responsiveness needs prompt attention. |
| Temperature | Site and method of measurement, and change from baseline. |
| Peripheral oxygen saturation (SpO₂) | Usually 95–100% in healthy individuals. Poor circulation, motion and skin pigmentation can affect the estimate. Consider the prescribed target and clinical condition. |
For example, a previously stable patient who becomes pale, confused and tachypnoeic during an examination needs assessment and help. Pause and alert the clinical team even if a single machine reading appears acceptable.
Infection Prevention and Aseptic Technique
Use standard precautions for every patient. Clean hands, choose personal protective equipment (PPE) according to splash or contact risk, handle sharps safely and clean shared surfaces and detectors between patients. The World Health Organization identifies five times to clean hands: before patient contact, before a clean or aseptic task, after body-fluid exposure risk, after patient contact and after touching patient surroundings. Use a hand rub when appropriate and soap and water for visibly soiled hands. Follow the facility's organism-specific precautions. India's National Centre for Disease Control (NCDC) prefers washing with soap and water after caring for a patient with suspected or confirmed C. difficile infection.
Clean technique interrupts transmission during routine care. Sterile technique protects the sterile field and key parts that contact sterile tissue. In angiography or image-guided biopsy, check that supplies are intact and that the field is ready before starting. If a nonsterile item touches a sterile component, stop and replace or re-establish the affected part of the field. Thread and handle covered equipment so it does not pull a detector or uncapped connector into the field.
| Additional precaution | Imaging example |
|---|---|
| Contact | Select gown and gloves as required for contact with the patient or their surroundings. Clean equipment before reuse. |
| Droplet | Use a medical mask per isolation policy when caring for a patient with a droplet-spread infection. Plan transport and use a patient mask if tolerated. |
| Airborne | Use a properly fitted particulate respirator such as N95 for infectious pulmonary tuberculosis, and use an airborne isolation room when indicated and available. Limit transport to essential examinations. |
Moving Patients With Devices
Plan the transfer around mobility, injury and clinical stability. Apply brakes, clear the route, choose the required staff and transfer aid, and assign someone to protect lines. Before leaving, confirm the prescribed oxygen delivery and that oxygen supply is sufficient. Keep tubing free from tension or kinks. Ask the responsible team to confirm restricted limbs, including an arm with dialysis access, before placing cuffs or starting vascular access.
An underwater-seal chest drain bottle stays upright and below the chest during transport. Keep the system connected and follow the treating team's drainage and clamping instructions. A urinary catheter bag stays below the bladder and off the floor. Keep it connected to its closed system. Check intravenous (IV) cannulas and pumps for dislodgement and coordinate transport with the person responsible for the infusion. These checks help prevent backflow, interrupted treatment and inadvertent removal.
Indian Bio-Medical Waste Segregation
Separate waste where it is generated under the Bio-Medical Waste Management Rules, 2016, as amended, using the containers in Schedule I. The 2026 amendment addresses administrative representation in rules 11 and 12. Apply the Schedule I categories when sorting these examples.
| Category | Examples in an imaging department |
|---|---|
| Yellow, using the prescribed bag or container for the waste type | Blood-soiled gauze and dressings. Discarded cytotoxic medicines and items contaminated with them follow the yellow pharmaceutical-waste route. |
| Red, non-chlorinated bag or container | Contaminated recyclable plastics, including IV tubing, catheters, urine bags, syringes without fixed needles and contaminated gloves. |
| White translucent, puncture-, leak- and tamper-proof container | Waste sharps including needles, fixed-needle syringes and scalpels. |
| Blue-marked, puncture- and leak-proof box or container | Contaminated non-cytotoxic glassware such as discarded glass ampoules, and metallic body implants. |
Sort by waste type and contamination. For example, a used needle goes into white even if its hub is plastic. Ordinary contaminated glass and a glass vial contaminated by a cytotoxic drug follow different routes. A red bag takes the used plastic tubing, and the treatment facility handles disinfection and recycling under the required process.
Before an abdominal radiograph in a ward patient who could be pregnant, which verification should the radiographer perform?
Confirm two patient identifiers and the requested examination, then ask about possible pregnancy and apply the screening protocol
Verify the patient's ward bed number against the requisition and proceed if the patient nods
Check the patient's full name only and ask whether they had breakfast
Confirm the referring physician's signature and skip pregnancy questioning for portable exams
A patient with confirmed active pulmonary tuberculosis is brought to the radiology department for an urgent chest radiograph. Which respiratory protection must the radiographer wear?
A standard surgical face mask only
Double sterile latex gloves without respiratory protection
A fit-tested N95 particulate respirator under airborne precautions
A face shield without a mask while standing behind the lead barrier
According to India's Biomedical Waste Management (BMW) Rules, 2016, in which container should used IV tubing, urinary catheters, and contaminated gloves from an interventional suite be segregated?
Yellow non-chlorinated bag
White translucent puncture-proof container
Blue puncture-proof box
Red non-chlorinated bag
Sections you finish are checked off in the contents.