8.4 Vascular, Myelography, Sialography & Fistulography Procedures
Key Takeaways
In classic Seldinger access, a guidewire preserves the path into the vessel while the puncture needle is replaced by a catheter.
Digital subtraction angiography (DSA) removes much of the stationary background by subtracting a precontrast mask from later frames. Motion between frames causes misregistration artefact.
For myelography, verify the exact nonionic presentation and iodine concentration authorised for intrathecal use. The drug name alone cannot establish that a vial is suitable.
Stensen's duct opens at the parotid papilla near the upper second molar. Wharton's duct opens beside the lingual frenulum. Defer conventional contrast sialography in acute sialadenitis.
Dacryocystography traces lacrimal drainage. Sinography and fistulography map an abnormal tract from an accessible opening and can show a communication with another structure.
In each procedure, identify the structure reached by the introducer or catheter and follow where the contrast is expected to travel. The route determines the preparation, the contrast presentation to check and what to monitor afterward.
Angiography and Digital Subtraction
The Seldinger technique obtains percutaneous access by replacing a hollow puncture needle with a catheter over a guidewire. Its sequence explains why the wire is essential.
- The operator punctures the selected vessel, for example the common femoral or radial artery, with imaging guidance as indicated.
- After confirming access, the operator threads the guidewire through the needle and into the lumen.
- The needle is withdrawn while the wire stays in place.
- The operator advances an introducer or catheter over the wire, then withdraws the wire when access is secure.
The catheter and tubing are prepared and flushed according to the device instructions and procedure protocol. The operator selects the flush solution and any anticoagulation for the procedure. Coordinate image acquisition and contrast delivery with the procedural team. Keep the sterile field intact and minimise fluoroscopy using appropriate collimation and acquisition settings.
In digital subtraction angiography (DSA), a precontrast image acts as a mask. The system compares corresponding pixels of that mask and subsequent images using logarithmic subtraction. If bone and soft tissue remain aligned, their background signal is largely cancelled, leaving the iodinated vessel visible. If the patient moves, a bone edge appears in different pixel locations before and after injection. Its residual double edge is a misregistration artefact. Pixel shifting can correct a small translation; rotation or local movement can require a new mask or another correction.
After the sheath is removed, confirm haemostasis according to the access-specific protocol. The team may use compression or an appropriate closure device. Monitor the puncture site, vital signs and distal perfusion. For femoral access, assess the foot for changes in pulses, colour or temperature per protocol. Promptly report new bleeding, an expanding swelling or a change in distal perfusion. Bed rest and observation depend on the access, closure method and individual instructions.
Myelography
Myelography uses fluoroscopy to image iodinated contrast in the subarachnoid space, often with subsequent CT. It can assess the thecal sac and nerve roots when MRI is unsuitable or images are limited by artefact. For lumbar access, the operator selects a level below the expected conus, such as L3–L4, using available imaging and the patient's anatomy. The operator confirms subarachnoid placement before intrathecal injection.
Use a nonionic contrast presentation specifically authorised for intrathecal administration, in the concentration indicated for the particular procedure. Verify the vial and procedure with the supervising clinician before use. Some presentations of iohexol and iopamidol are labelled for intrathecal procedures. Other products or concentrations with the same drug name can be inappropriate. For example, the iohexol label warns that intrathecal administration of its 350 mg iodine/mL presentation can cause seizures, severe neurological injury or death.
The team gives position, hydration and observation instructions for the actual study and product. The ACR–ASNR–SPR parameter calls for adequate hydration, monitoring and discharge instructions that cover persistent headache, reaction symptoms and signs of puncture-site infection. Confirm the ordered aftercare before transferring the patient. A single bed angle or fixed rest interval does not apply across studies.
Salivary, Lacrimal and Cutaneous Tract Imaging
| Study | Access and imaging objective | Important distinction |
|---|---|---|
| Sialography | Cannulate the relevant salivary duct and introduce contrast to show its lumen and branches | Parotid uses Stensen's duct. Submandibular uses Wharton's duct. Defer conventional contrast injection in acute sialadenitis |
| Dacryocystography (DCG) | Introduce contrast via a lacrimal punctum to outline the canaliculi, lacrimal sac and nasolacrimal duct | Helps localise obstruction in symptomatic tearing. Use the projections or subtraction technique for the specific exam |
| Sinography or fistulography | Instil contrast from an accessible cutaneous opening and acquire views as the tract fills | A sinus may end blindly. A fistula can connect the skin to another structure such as bowel |
In sialography, Stensen's duct opens on the inside of the cheek near the upper second molar. Wharton's duct opens on the floor of the mouth beside the lingual frenulum. An elective sialogram can assess a duct stricture or stone. A sialogogue such as lemon juice can stimulate flow in the preparation or drainage phase according to the protocol. Painful gland swelling with purulence at the parotid duct opening suggests acute infection. Defer conventional contrast sialography and let the clinician choose the indicated noninvasive imaging, such as ultrasound.
In dacryocystography, a clinician may cannulate the lower punctum and instil nonionic contrast. Follow its passage along the nasolacrimal drainage system. An abrupt stop or reflux can help localise obstruction. When documenting contrast passage into the nose, include the expected termination in the inferior nasal meatus.
In a fluoroscopic sinogram or fistulogram of a cutaneous opening, the operator uses a suitable catheter and gently injects water-soluble contrast. Multiple projections can show the tract course and help identify any organ it communicates with. For a blind-ending tract or cavity, a frontal and a lateral view can document its relationship to surrounding structures. If planar images cannot show the needed spatial detail or the surrounding tissues, cross-sectional imaging can add information.
During percutaneous femoral angiography using the Seldinger technique, what is the correct sequence of steps immediately after pulsatile arterial blood return confirms needle placement?
Remove the needle first, then thread the catheter directly through the skin tract
Inject full-strength contrast through the needle, then advance a pigtail catheter
Advance the guidewire through the needle, withdraw the needle, advance the catheter over the wire, and remove the guidewire
Inflate a vascular closure device before advancing the guidewire into the iliac artery
The authorised product for a planned intrathecal iohexol study is unavailable. A vial of iohexol marked 350 mg iodine/mL is offered instead. What should the radiography team do?
Use the vial because the generic drug name matches
Hold the injection and verify an authorised intrathecal presentation and concentration with the supervising clinician
Use the same volume and raise the head of the bed afterward
Use the vial after a negative history of prior contrast reaction
A patient presents with painful, swollen parotid gland and purulent discharge expressed from the duct opening opposite the upper second molar. What is the appropriate radiographic decision regarding contrast sialography?
Proceed immediately with Stensen's duct cannulation using high-pressure oil-based contrast
Cannulate Wharton's duct beneath the lingual frenulum instead to bypass the parotid gland
Administer oral barium sulfate to outline adjacent pharyngeal structures before cannulation
Defer contrast sialography and discuss an appropriate noninvasive study with the supervising clinician
Sections you finish are checked off in the contents.