4.4 Capillary (Dermal) Puncture: Adult Fingerstick & Infant Heelstick
Key Takeaways
Capillary collection is useful when small samples are sufficient and the laboratory accepts the capillary matrix.
For an approved finger collection, use the palmar surface of an appropriate finger such as the middle or ring finger, with the incision crossing the fingerprint ridges.
For newborn screening, use the approved medial or lateral plantar heel site and a device selected for the infant and screening program.
Use the first-drop instructions for the collection. Alberta’s screening procedure discards it and collects free-flowing blood with gentle pressure.
Capillary tube order differs from venous order. Alberta Precision Laboratories places a newborn screening card after a capillary blood gas and before EDTA when all are ordered.
Capillary blood collection obtains a small-volume specimen through a skin puncture. It can reduce the amount of blood removed when the requested tests can be performed on small volumes. Verify the test’s approved matrix before choosing this route. A capillary specimen can differ from a venous specimen, and some tests require a specimen source to appear on the label or in the laboratory record.
Decide Whether Capillary Collection Is Suitable
Capillary sampling can be useful for infants, difficult venous access and approved point-of-care devices. Confirm each requested test and tube with the laboratory’s directory. For example, Horizon’s collection manual identifies blood cultures and high-volume sampling as situations that can require another method. Standard laboratory and point-of-care coagulation methods may accept different specimen types. The fact that a meter can use a fingerstick for one measurement does not make capillary blood acceptable for every test with a related name.
| Collection | Site and tool considerations |
|---|---|
| Finger puncture | Horizon prefers the middle or ring finger, using the palmar surface of the distal segment and crossing the fingerprint ridges. Avoid the very tip or side where tissue is thinner, and avoid the fifth finger. Follow local age, site and approved device requirements. |
| Infant heel puncture | Use an approved medial or lateral plantar site to reduce the chance of reaching the heel bone. Avoid the posterior curve and previous puncture sites. Select the device and depth according to the infant and the screening program. |
| Newborn dried blood spot | Use the provincial screening program’s approved heel device and requisition card. Newborn Screening Ontario specifies a lancet tip no longer than 2 mm and a shorter tip for babies under 1,500 g. Some institutions specify shallower devices. |
Prepare, Collect and Check
Position and identify the patient under local protocol. For a newborn, match the infant’s own assigned identifiers to the order and screening card. Alberta Health Services lists optional warming measures to encourage blood flow, including an approved infant heel warmer or a comfortably warm cloth for three to five minutes. Follow the approved instructions for the patient and device.
For an Alberta screening heel collection, cleanse with 70% isopropyl alcohol and allow the skin to air dry. Use an approved sterile single-use device and dispose of it promptly in the sharps container. Wipe away the first drop according to the screening procedure because it may contain diluting tissue fluid. Follow the relevant instructions for other uses, including any point-of-care device. Use gentle intermittent pressure to form a hanging drop and avoid repetitive squeezing. Vigorous pressure can cause hemolysis or tissue-fluid dilution.
Let the blood reach each container as directed. For a dried blood spot, touch the paper to a hanging drop rather than pressing it against the skin. Allow the required circles to fill and check the program’s instructions for drying, labelling and shipment. For microcollection tubes, meet the device’s fill range and use the appropriate mixing steps.
Order and Aftercare
When all are requested together, Alberta Precision Laboratories gives this order for skin puncture.
- Capillary blood gas.
- Newborn metabolic screening card.
- EDTA microcollection tube, such as for an approved complete blood count (CBC).
- Other additive microcollection tubes.
- Serum microcollection tubes.
Use only the steps for the specimens ordered. Verify the site’s procedure for the position of a screening card. The EDTA tube goes early in the microcollection series to reduce clotting and platelet clumping. The instrument, tube and test directory still govern fill, mixing and transport.
Check the puncture site after collection. Follow the protocol for gauze, pressure and dressings. Alberta’s newborn blood spot procedure uses gauze until bleeding stops and omits adhesive bandages. Complete the identification and collection documentation while the specimen is traceable to the patient.
Worked Newborn Collection
An Alberta site has a newborn blood spot card and a bilirubin microcollection tube due at the same encounter. The collector checks the infant’s own identifiers against both orders, confirms the lab accepts capillary blood for the bilirubin request, and prepares the specified tube and light protection. The facility uses the Alberta Precision Laboratories skin-puncture order, so the card comes before the bilirubin microtube. After collecting, the MLA achieves hemostasis, checks both labels and handles the dried blood spot and bilirubin according to their distinct requirements. The card must dry under the screening procedure. The bilirubin tube uses the protection specified by the performing laboratory.
See Horizon’s May 2026 manual, pp. 9–10 and 38–40, Alberta Health Services newborn blood spot procedure, Newborn Screening Ontario collection tip sheet, Alberta Precision Laboratories skin-puncture order.
For a full-term newborn’s dried blood spot collection under Newborn Screening Ontario guidance, which site and device meet the program’s instructions?
Centre of heel using a 2.4 mm tip
Posterior curve using a 2.0 mm tip
Ring finger using a 1.5 mm device
Approved side of the plantar heel using a lancet tip no longer than 2 mm
Under Alberta’s newborn screening procedure, why wipe away the first drop and avoid strong repetitive pressure on the heel?
To activate the clotting factors needed for serum samples
First-drop tissue fluid may dilute the sample, and strong pressure can add tissue fluid or damage cells
To keep all capillary blood from clotting without mixing
To avoid having to let the site air dry
At a site following Alberta Precision Laboratories skin-puncture order, the only orders are a capillary blood gas, a CBC, a heparin microtube and a serum microtube. What is the sequence?
Serum, heparin, EDTA, gas
EDTA, serum, gas, heparin
Gas, EDTA, heparin, serum
Gas, serum, EDTA, heparin
Sections you finish are checked off in the contents.