6.2 Specimen Suitability, Rejection Criteria & Pre-Analytical Errors

Key Takeaways

  • Check acceptable identifiers, matrix, required volume, working container and time and temperature limits against the specific test.

  • Hemolysis can elevate potassium, lactate dehydrogenase and aspartate aminotransferase. Use validated interference rules for each method.

  • Icterus and lipemia can interfere with methods. Marked lipemia can bias sodium downward on an indirect ion-selective electrode.

  • Never guess a missing identifier or silently relabel a specimen. Document and apply the appropriate disposition rule.

  • Hold irreplaceable samples securely and promptly consult the authorized team about the applicable exception pathway.

Last updated: November 2026

Specimen suitability asks whether a sample can produce a reliable result for a particular test. Consider identity, matrix, volume, condition and the handling history. Different tests run on the same tube can have different acceptance limits. The MLA flags problems and follows the disposition process rather than deciding alone that a sample is safe to test.

Check the Primary Container

CheckWhat to verify
IdentificationMatch required identifiers, specimen source and order. If identity is uncertain, hold before proceeding.
Matrix and containerVerify the sample type and approved additive or preservative. Use the test directory and tube label.
FillCompare volume with the minimum and, where applicable, the fill mark. Check ratio-dependent tubes carefully.
ConditionInspect for cracks, leakage, a displaced cap or clots when the test needs anticoagulated blood.
Time and temperatureCompare actual collection, receipt and processing times and the recorded handling conditions with the test instructions.
Potential interferenceAssess separated serum or plasma according to local guidance and communicate an appearance or instrument flag.

A citrate specimen designed for nine parts blood to one part citrate requires the appropriate fill. If the tube draws much less blood, extra citrate relative to plasma can bind assay calcium and prolong measured clotting times. The laboratory defines the fill threshold and action. A clotted specimen ordered for an anticoagulated whole-blood measurement is another important example. A clot can entrap cells and make the counted portion unrepresentative. Document the actual defect rather than combining tubes or trying to remove a clot and continue.

Hemolysis, Icterus and Lipemia

Hemolysis is red blood cell rupture. Pink or red separated serum or plasma can flag it. Intracellular release and method interference can increase measured potassium, lactate dehydrogenase (LDH) and aspartate aminotransferase (AST). The colour does not tell you whether the cause occurred before or after collection. Some analysers estimate a hemolysis index. Use the required method-specific rule for notifying the bench and for any result hold, comment or recollection.

Icterus refers to the sample’s bilirubin-associated colour and potential interference. Lipemia refers to turbidity caused by lipoproteins. The degree and direction of bias depend on the method and analyte. In particular, marked lipemia can make sodium appear low by an indirect ion-selective electrode because the method dilutes a sample with a reduced water fraction. A method using an undiluted sample can behave differently. Flag the observed issue and follow the laboratory’s validated interference and result-review policy.

A cloudy sample and a pink one arrive for identical panels. These are distinct observations. Neither appearance alone tells the MLA which tests can be reported. Capture the flag for the receiving bench rather than predicting numbers or assigning a clinical diagnosis.

Separate Appearance From the Disposition

Suppose the analyser gives a high lipemia index while the order includes sodium and another measurement. Check the sample type and relevant interference limits. The same flag can have different consequences for the two measurements. A different acceptable method may be available, but the authorized laboratory professional decides which measurements can proceed. Record the observed flag, document the communication, and preserve the sample as required while the decision is pending. A repeat collection or alternative method must remain traceable to the original order and the reason for the change.

Routine and Irreplaceable Specimens

For a routinely recollectable tube with no reliable identity, follow the site’s rejection, notification and recollection procedure. Some minor discrepancies have authorized correction steps, and some tests such as pre-transfusion testing have stricter rules. Do not create a corrected label based on a guess.

An invasive or irreplaceable specimen may need an exception decision. Alberta Precision Laboratories describes collector identification and a waiver in specified cases. Public Health Ontario describes a submitting provider waiver for qualifying critical specimens that fail its identifier criteria. Those examples have different responsible parties. Keep the sample secure, preserve its actual condition, and escalate promptly. Record the eventual authorized disposition and any report annotation required by local protocol.

Worked Decision

An urgent cerebrospinal fluid (CSF) tube has an incomplete label and an unclear time. Hold it in secure, appropriate storage pending an immediate discussion with the supervising laboratory professional and submitting team. Document the missing fields and the circumstances of receipt. Do not use the recorded receipt time as the collection time. An approved exception must establish what can be verified and who authorized it. If the team cannot verify the specimen, use the laboratory’s unresolved discrepancy procedure.

See APL sample acceptance guidance, Public Health Ontario specimen acceptance, APL blood collection factors, CLSI PRE04, Hemolysis interference study, Lipemia and indirect sodium study.

Loading diagram...
Specimen Suitability and Exception Decisions
Test Your Knowledge

A separated serum specimen is flagged for hemolysis. Which group of results is susceptible to an upward bias from in vitro cell rupture?

A

Sodium, chloride and bicarbonate

B

Potassium, LDH and AST

C

Calcium, albumin and bilirubin

D

Glucose, urea and creatinine as a group

Test Your Knowledge

An invasive CSF specimen arrives with incomplete identification. What should the MLA do immediately?

A

Secure it, record the discrepancy and promptly notify the designated laboratory professional

B

Discard it without review

C

Enter the receipt time as the collection time and test

D

Ask the courier to certify the patient’s identity

Test Your Knowledge

A citrate specimen for clotting tests has collected only 60% of its intended blood volume. Why is it unsuitable under the lab’s fill rule?

A

The clotting time must shorten because calcium increases

B

The short draw raises fibrinogen concentration by design

C

The fixed citrate volume is excessive relative to blood and can bind reagent calcium, prolonging measured clotting

D

An aspiration probe can correct the blood-to-additive ratio

Sections you finish are checked off in the contents.