3.2 CLSI Order of Draw & Preventing Additive Carryover
Key Takeaways
CLSI PRE02 places blood culture first, then citrate, serum, heparin, EDTA and glycolysis inhibitor tubes.
Potassium EDTA contamination can raise measured potassium and lower calcium and magnesium. A reversed sequence alone does not confirm contamination.
For venous transfer into evacuated tubes, keep serum ahead of heparin and let the approved transfer device and tube vacuum do the work.
A capillary series places the blood gas before EDTA and serum. Check the site’s position for newborn screening cards when those are ordered.
Communicate an unexpected result or collection deviation through the laboratory’s established process and keep specimens traceable.
The Clinical and Laboratory Standards Institute (CLSI) gives the venous order of draw in PRE02, its eighth edition of Collection of Diagnostic Venous Blood Specimens. PRE02 replaced GP41 in 2025. Standardizing the sequence addresses specimen contamination risk and makes a collection reproducible. Use the site’s instructions for tubes outside the ordinary sequence.
Venous Order of Draw
| Order | Family | Why this position matters |
|---|---|---|
| 1 | Blood culture containers | The clinical protocol protects the specimen against contamination. |
| 2 | Sodium citrate | Collect coagulation specimens before tubes containing clot activators or other anticoagulants. |
| 3 | Serum, with or without clot activator and gel | Serum tubes need clot formation. Keep heparin and EDTA later in the sequence. |
| 4 | Heparin, with or without gel | Heparin provides anticoagulated plasma for compatible tests. |
| 5 | EDTA, with or without gel | Potassium EDTA can alter electrolyte measurements if it contaminates a chemistry specimen. |
| 6 | Glycolysis inhibitor | Use the required tube, such as fluoride/oxalate, for specified tests. |
The sequence concerns additives and intended use. Some caps are shared by otherwise different tubes. A trace-element tube, for example, may follow different placement instructions depending on its additive and contamination requirements. If blood cultures are part of the order, the culture protocol also specifies which bottle gets filled first for the device used. For a winged set, the approved procedure can place the aerobic bottle first so the initial tubing air enters that bottle. Verify the bottle instructions and local procedure for syringe collections.
Venous Collection by Syringe
When a syringe collection is authorized, use the approved closed transfer device under its instructions. Alberta Precision Laboratories applies the same venous sequence to syringe blood transferred into evacuated tubes. Let the vacuum pull blood into the tube. Pushing the plunger can cause hemolysis or overfill. Retain the stoppers, keep track of the tubes and perform the required gentle inversions after filling.
For a citrate, serum, heparin and EDTA order, lay out the tubes in that order before attaching the transfer device. Check each additive and fill as you go. A citrate sample placed after serum cannot be corrected with an extra inversion. Follow the laboratory’s procedure for a sequence deviation and record which tubes were involved.
Capillary Collection Has Its Own Sequence
With a skin puncture, collect the capillary blood gas before other specimens when ordered. The lab controls air exposure and time to analysis. The EDTA microcollection tube is collected early because platelets can aggregate during a prolonged collection. Serum follows the additive microtubes.
| Order in the Alberta Precision Laboratories example | Specimen |
|---|---|
| First | Capillary blood gas |
| Next, if ordered | Newborn metabolic screening card |
| Next | EDTA microcollection |
| Then | Other additive microcollection tubes |
| Last | Serum microcollection |
The card is a separate specimen type and appears in the order where the jurisdiction’s screening and local collection instructions place it. Check whether each requested test is validated for capillary blood before setting up a skin puncture. The venous order applies to evacuated venous tubes. The microcollection procedure applies to the small-volume specimens.
Recognizing a Possible Additive Error
Potassium EDTA adds potassium and binds calcium and magnesium. A sample with falsely high potassium and unexpectedly low calcium and magnesium can raise suspicion for contamination. Effects on some enzymes, including alkaline phosphatase, can also occur. The pattern warrants review by the technologist. The MLA checks collection details, confirms the tube labels and documents the event.
A wrong draw sequence is a process deviation. Studies of specific closed systems have found no detectable EDTA contamination when a serum tube was drawn after an EDTA tube. Contamination is documented with practices such as inappropriate open transfer. Keep the prescribed order and avoid pouring blood between tubes. A single result pattern should not be used to decide whether a patient needs care.
Consider a venous specimen order for a chemistry panel and CBC. After a short draw, the collector reports transferring some blood from the EDTA tube into the chemistry tube. The laboratory flags high potassium and low calcium. The documented transfer makes the chemistry specimen unsuitable and provides a concrete explanation for possible interference. Report the handling error immediately, follow the result and recollection protocol, and preserve the record. If no handling error is known, escalate the values through the normal procedure for urgent results while the technologist investigates.
See the CLSI PRE02 eighth-edition quick guide, APL venous order and transfer, APL skin-puncture order, and the study of EDTA contamination in open and closed systems.
A chemistry specimen shows unexpectedly high potassium and low calcium and magnesium. The collection note says blood from the lavender potassium EDTA tube was poured into the chemistry tube. Which error best accounts for the findings?
The gold SST was centrifuged before the 30-minute clotting period finished
A light blue sodium citrate tube was drawn before the chemistry tube
Contamination with potassium EDTA during transfer between collection tubes
Vigorous shaking caused mechanical hemolysis of the red blood cells
A site uses the Alberta Precision Laboratories skin-puncture order. The only specimens ordered are a capillary blood gas, a CBC and serum bilirubin. In what order should the MLA collect them?
Blood gases first, then EDTA lavender, then serum bilirubin last
Serum bilirubin first, then blood gases, then EDTA lavender last
EDTA lavender first, then serum bilirubin, then blood gases last
Blood gases first, then serum bilirubin, then EDTA lavender last
An MLA draws blood using a 10 mL syringe from a patient with fragile veins and attaches a safety blood transfer device. What is the correct practice when filling a light blue citrate tube, a gold SST, and a lavender EDTA tube?
Fill the lavender EDTA tube first, push the plunger firmly, then fill gold and light blue
Remove the tube stoppers, dispense blood slowly down the wall, and recap all tubes
Fill gold SST first, then lavender EDTA, then light blue citrate using gentle plunger pressure
Transfer into light blue first, then gold SST, then lavender EDTA, allowing tube vacuum to draw the blood
Sections you finish are checked off in the contents.