3.2 CLSI Order of Draw & Preventing Additive Carryover

Key Takeaways

  • CLSI PRE02 places blood culture first, then citrate, serum, heparin, EDTA and glycolysis inhibitor tubes.

  • Potassium EDTA contamination can raise measured potassium and lower calcium and magnesium. A reversed sequence alone does not confirm contamination.

  • For venous transfer into evacuated tubes, keep serum ahead of heparin and let the approved transfer device and tube vacuum do the work.

  • A capillary series places the blood gas before EDTA and serum. Check the site’s position for newborn screening cards when those are ordered.

  • Communicate an unexpected result or collection deviation through the laboratory’s established process and keep specimens traceable.

Last updated: November 2026

The Clinical and Laboratory Standards Institute (CLSI) gives the venous order of draw in PRE02, its eighth edition of Collection of Diagnostic Venous Blood Specimens. PRE02 replaced GP41 in 2025. Standardizing the sequence addresses specimen contamination risk and makes a collection reproducible. Use the site’s instructions for tubes outside the ordinary sequence.

Venous Order of Draw

OrderFamilyWhy this position matters
1Blood culture containersThe clinical protocol protects the specimen against contamination.
2Sodium citrateCollect coagulation specimens before tubes containing clot activators or other anticoagulants.
3Serum, with or without clot activator and gelSerum tubes need clot formation. Keep heparin and EDTA later in the sequence.
4Heparin, with or without gelHeparin provides anticoagulated plasma for compatible tests.
5EDTA, with or without gelPotassium EDTA can alter electrolyte measurements if it contaminates a chemistry specimen.
6Glycolysis inhibitorUse the required tube, such as fluoride/oxalate, for specified tests.

The sequence concerns additives and intended use. Some caps are shared by otherwise different tubes. A trace-element tube, for example, may follow different placement instructions depending on its additive and contamination requirements. If blood cultures are part of the order, the culture protocol also specifies which bottle gets filled first for the device used. For a winged set, the approved procedure can place the aerobic bottle first so the initial tubing air enters that bottle. Verify the bottle instructions and local procedure for syringe collections.

Venous Collection by Syringe

When a syringe collection is authorized, use the approved closed transfer device under its instructions. Alberta Precision Laboratories applies the same venous sequence to syringe blood transferred into evacuated tubes. Let the vacuum pull blood into the tube. Pushing the plunger can cause hemolysis or overfill. Retain the stoppers, keep track of the tubes and perform the required gentle inversions after filling.

For a citrate, serum, heparin and EDTA order, lay out the tubes in that order before attaching the transfer device. Check each additive and fill as you go. A citrate sample placed after serum cannot be corrected with an extra inversion. Follow the laboratory’s procedure for a sequence deviation and record which tubes were involved.

Capillary Collection Has Its Own Sequence

With a skin puncture, collect the capillary blood gas before other specimens when ordered. The lab controls air exposure and time to analysis. The EDTA microcollection tube is collected early because platelets can aggregate during a prolonged collection. Serum follows the additive microtubes.

Order in the Alberta Precision Laboratories exampleSpecimen
FirstCapillary blood gas
Next, if orderedNewborn metabolic screening card
NextEDTA microcollection
ThenOther additive microcollection tubes
LastSerum microcollection

The card is a separate specimen type and appears in the order where the jurisdiction’s screening and local collection instructions place it. Check whether each requested test is validated for capillary blood before setting up a skin puncture. The venous order applies to evacuated venous tubes. The microcollection procedure applies to the small-volume specimens.

Recognizing a Possible Additive Error

Potassium EDTA adds potassium and binds calcium and magnesium. A sample with falsely high potassium and unexpectedly low calcium and magnesium can raise suspicion for contamination. Effects on some enzymes, including alkaline phosphatase, can also occur. The pattern warrants review by the technologist. The MLA checks collection details, confirms the tube labels and documents the event.

A wrong draw sequence is a process deviation. Studies of specific closed systems have found no detectable EDTA contamination when a serum tube was drawn after an EDTA tube. Contamination is documented with practices such as inappropriate open transfer. Keep the prescribed order and avoid pouring blood between tubes. A single result pattern should not be used to decide whether a patient needs care.

Consider a venous specimen order for a chemistry panel and CBC. After a short draw, the collector reports transferring some blood from the EDTA tube into the chemistry tube. The laboratory flags high potassium and low calcium. The documented transfer makes the chemistry specimen unsuitable and provides a concrete explanation for possible interference. Report the handling error immediately, follow the result and recollection protocol, and preserve the record. If no handling error is known, escalate the values through the normal procedure for urgent results while the technologist investigates.

See the CLSI PRE02 eighth-edition quick guide, APL venous order and transfer, APL skin-puncture order, and the study of EDTA contamination in open and closed systems.

Loading diagram...
CLSI PRE02 Venous Order of Draw
Test Your Knowledge

A chemistry specimen shows unexpectedly high potassium and low calcium and magnesium. The collection note says blood from the lavender potassium EDTA tube was poured into the chemistry tube. Which error best accounts for the findings?

A

The gold SST was centrifuged before the 30-minute clotting period finished

B

A light blue sodium citrate tube was drawn before the chemistry tube

C

Contamination with potassium EDTA during transfer between collection tubes

D

Vigorous shaking caused mechanical hemolysis of the red blood cells

Test Your Knowledge

A site uses the Alberta Precision Laboratories skin-puncture order. The only specimens ordered are a capillary blood gas, a CBC and serum bilirubin. In what order should the MLA collect them?

A

Blood gases first, then EDTA lavender, then serum bilirubin last

B

Serum bilirubin first, then blood gases, then EDTA lavender last

C

EDTA lavender first, then serum bilirubin, then blood gases last

D

Blood gases first, then serum bilirubin, then EDTA lavender last

Test Your Knowledge

An MLA draws blood using a 10 mL syringe from a patient with fragile veins and attaches a safety blood transfer device. What is the correct practice when filling a light blue citrate tube, a gold SST, and a lavender EDTA tube?

A

Fill the lavender EDTA tube first, push the plunger firmly, then fill gold and light blue

B

Remove the tube stoppers, dispense blood slowly down the wall, and recap all tubes

C

Fill gold SST first, then lavender EDTA, then light blue citrate using gentle plunger pressure

D

Transfer into light blue first, then gold SST, then lavender EDTA, allowing tube vacuum to draw the blood