3.1 Evacuated Tube Additives, Anticoagulants & Blood-to-Additive Ratios
Key Takeaways
A correctly filled standard sodium citrate coagulation tube has a 9:1 blood-to-citrate ratio. Underfilling leaves excess citrate relative to the blood and can prolong measured clotting times.
Prime a winged set with a laboratory-approved discard tube when citrate is the first specimen tube needed.
Heparin promotes the action of antithrombin. Select a different approved matrix for a lithium level because a lithium heparin tube introduces lithium.
EDTA binds calcium and keeps blood anticoagulated for hematology. Sodium fluoride inhibits enolase but does not arrest glucose loss immediately after collection.
Use the label and the test directory to confirm the additive, volume, mixing and processing for the collection system in use.
Choose the collection tube by the specimen matrix and additive required for the test. An evacuated tube can contain an anticoagulant, a clot activator, a separator gel or no additive. Similar cap colours can mean different things across product lines, and a colour alone does not tell you whether a particular test accepts the tube.
Whole Blood, Plasma and Serum
An anticoagulant prevents clot formation. The laboratory can use whole blood from a suitable anticoagulant tube for tests that measure or examine cells. Centrifugation separates the cells from plasma, which retains soluble clotting proteins. Serum is the fluid after a specimen clots. Most of its fibrinogen has been converted to fibrin and incorporated into the clot. A serum tube may be plain or contain an activator to promote clotting. Wait for the validated clotting period before processing a serum specimen.
| Tube family and common examples | How it works | How to check suitability |
|---|---|---|
| Light-blue sodium citrate coagulation tube | Citrate binds calcium. The method adds calcium back to permit measurement of clot formation. | Verify correct concentration and fill for prothrombin time (PT), international normalized ratio (INR) and activated partial thromboplastin time (aPTT). |
| Serum tube, including a gold-top serum separator tube (SST) in common systems | An activator can speed clotting. A separator gel moves between the clot and serum during centrifugation. | Check whether the test accepts gel. Different serum tubes can require different clotting and centrifugation conditions. |
| Heparin tube, including light-green lithium heparin plasma separator tube (PST) in common systems | Heparin enhances antithrombin activity, suppressing thrombin and factor Xa. | Check the heparin salt and gel compatibility. The lab can separate suitable plasma without waiting for a clot to form. |
| Lavender or pink ethylenediaminetetraacetic acid (EDTA) tube | EDTA binds calcium and prevents clot formation. | Commonly used for a complete blood count (CBC). Select the approved tube and additional identification steps for pre-transfusion specimens. |
| Grey glycolysis inhibitor tube | In a fluoride/oxalate tube, sodium fluoride inhibits enolase and oxalate is the anticoagulant. | Follow the test directory’s stabilization and separation times. Some glucose collection systems use different additives. |
| Specialty tubes | A trace-element tube helps control external contamination. An acid citrate dextrose (ACD) tube supplies an anticoagulant and dextrose. | Check the precise product and test requirements. Some specialty families have multiple additives under similar caps. |
Why the Citrate Fill Matters
A standard specimen collected in a 3.2% sodium citrate tube needs 9 parts blood to 1 part citrate. For an illustrative tube designed for 2.7 mL of blood and already containing 0.3 mL of citrate, the intended mixture is 3.0 mL and the ratio is to 1. A half-volume draw adds 1.35 mL of blood to the same liquid additive, so to 1. It has twice the intended amount of citrate per unit volume of blood.
In the test method, excess citrate can bind some of the reagent calcium. Clot formation can then appear slower than it would in a properly filled specimen. Assess the tube against its specified fill mark and the laboratory’s acceptance rule. Mixing can distribute the additive but cannot restore the missing blood volume. Combining two short tubes also combines two measures of citrate.
When citrate is the first specimen tube on a winged collection set, air in the tubing can take up some of the evacuated tube’s capacity. Use the approved discard tube to prime the line before filling the specimen tube. Different sets have different dead space. For patients with a high hematocrit, a normal whole-blood fill can still leave more citrate relative to plasma. Follow the lab’s special collection instructions or consult the coagulation bench.
Additive Choice, Mixing and Delays
- Heparin salts. A lithium heparin tube adds lithium, so it cannot provide an uncontaminated lithium measurement. Confirm the validated tube for the test and site. For example, Dynacare’s Québec specimen manual specifies a serum gel tube for its lithium test. Consult the test directory for other drug levels and gel compatibility.
- EDTA. CBC methods use the anticoagulated cell suspension. Potassium EDTA in a chemistry specimen can add potassium and bind calcium. These mechanisms explain why moving blood between collection tubes can change results.
- Glycolysis inhibitors. Blood cells continue using glucose after collection. Fluoride inhibits a late step in glycolysis, so fluoride alone provides limited protection during the first hours. Use the lab’s specified processing interval, even when the tube contains a glycolysis inhibitor.
- Mixing. A gentle inversion takes the tube through one complete upside-down and upright cycle. Use the count specified for the product and laboratory. For example, Alberta Precision Laboratories lists 3–4 inversions for its venous citrate tube and 8–10 for several EDTA tube types. Shaking can damage cells, and poor mixing can leave additive tubes with clots.
Suppose a winged set was used for an INR and a CBC. Citrate was collected first and the tube fell below the required fill mark. Hold the coagulation specimen and follow the laboratory’s recollection instructions. Verify the CBC tube separately under its own acceptance criteria. To avoid a repeat problem, prime the line with an approved discard tube and then check the fill and mixing of each specimen.
See Alberta Precision Laboratories order and mixing guide, collection error guidance, Dynacare’s Québec test directory and the glucose stability study.
A standard citrate tube is designed for 2.7 mL of blood and contains 0.3 mL citrate. It collects only 1.35 mL of blood. What is the blood-to-citrate ratio, and what is the main concern?
The ratio is 9:1 and vigorous mixing corrects the problem
The ratio is 4.5:1 and excess citrate relative to blood can prolong measured clotting times
The ratio is 4.5:1 and the measured clotting time must shorten
The ratio is 18:1 and the test can proceed after centrifugation
The test directory specifies lithium heparin plasma for an urgent chemistry panel and serum from an approved serum separator tube for a lithium level. Which supplies should the MLA select?
Use one EDTA tube for both orders
Use serum for both orders without checking whether the chemistry panel accepts it
Use one lithium heparin tube for all analytes
Use a lithium heparin tube for the chemistry panel and the approved serum separator tube for lithium
Why must a specimen in a fluoride/oxalate tube still be processed within the laboratory’s validated time for glucose?
Fluoride inhibits enolase but glucose can continue to fall during early storage
It irreversibly chelates calcium to stop enzymatic phosphorylation of hexokinase
It activates antithrombin to block thrombin-mediated glucose consumption
It lyses red blood cells so intracellular glucose stabilizes plasma levels