10.2 Engineering Controls, Biosafety Cabinets, Disinfection & Sharps Disposal
Key Takeaways
Start with higher-level hazard controls and use PPE with the other controls required for the task.
Match the enclosure to the hazard and the laboratory’s risk assessment and procedure.
Use validated cleaning, disinfection and sterilization methods for the surface, item or load.
Before collection, verify that the designated sharps container is accessible and below its fill limit.
Activate the device safety feature as directed and discard intact single-use assemblies immediately.
A biosafety measure can remove a hazard, separate people from it or reduce the chance of contact. The hierarchy of controls starts with elimination and substitution. Engineering controls then isolate the hazard with the design of equipment or the workspace. Administrative controls include training and procedures. Personal protective equipment (PPE) provides a wearable barrier. Multiple controls often apply to the same task.
Match the Control to the Hazard
| Control | Laboratory example |
|---|---|
| Eliminate or substitute | Use an approved collection method that removes an unnecessary sharp, or substitute a compatible lower-hazard material. |
| Engineer | Use an approved sealed centrifuge rotor or safety cup, a safety-engineered needle, or a designated containment enclosure. |
| Administer | Require trained operators, document checks and keep unauthorized workers away from a hazard. |
| Protect the worker | Wear the eye protection and other PPE selected for the exposure. |
Before beginning a task at a laboratory enclosure, verify the approved use, instrument status, and any pre-use checks required for that model. A certified and operating Class II biological safety cabinet (BSC) is designed to protect personnel, the work material and the environment for the approved biological task. A clean bench protects the work from contamination and is inappropriate for a hazardous clinical specimen. A chemical fume hood is designed for chemical exposure control. Selecting a fume hood because it has an opening similar to a BSC would overlook the difference in purpose.
Check the BSC certification or service status, sash setting and indicators according to the facility’s instructions. Keep the grilles clear as the procedure requires and stop work if there is an airflow alarm. Do not assume a cabinet is suitable for a chemical because it contains a high-efficiency particulate air (HEPA) filter. A filter for airborne particles does not by itself control chemical vapours.
Biosafety risk group and containment level describe different things. Risk group characterizes the hazard of an agent, while containment level describes the safeguards for the work. PHAC’s human diagnostic guidance uses an activity-specific risk assessment. If an unexpected finding changes the risk or required containment, secure the material and promptly notify the assigned supervisor for direction. Use the facility’s approved work under its applicable authorities.
Choose the Correct Surface or Equipment Process
Cleaning removes soil and can prepare a surface for disinfection. Antisepsis uses a product specified for living tissue. Disinfection on an inanimate surface depends on the approved product, conditions and applicable contact time. Sterilization uses a validated process designed to eliminate viable microorganisms, including resistant spores. Use the product directions and the local process for the actual item. A skin preparation does not automatically qualify as a bench disinfectant.
After a routine surface spill, the worker trained and assigned to respond uses the facility’s spill procedure. Confirm the intended surface and the required cleaning step, disinfectant, concentration and wet contact time. Do not assume that an unlabelled dilution has the required concentration or that a brief wipe gives the required contact. A steam sterilizer cycle also depends on the load and validated monitoring. Use the documented release criteria. A single process tape colour change cannot establish that all criteria for the load were met.
Prevent Sharps Injuries
Ontario’s Needle Safety Regulation requires safety-engineered needles for the specified work, subject to its defined exceptions. Use the approved device and follow that specific safety feature’s activation instructions. Verify that there is an appropriate, upright container within reach before starting. Discard the used single-use needle and holder as an intact assembly when the system requires it. Never force a used sharp into a full container.
When setting up a collection station, distinguish replacing a filled container from disposing of a single needle. The replacement needs a stable location and a clear opening. The full unit follows the local closure and removal procedure, which protects housekeeping and transport staff as well as the collector. Ask for a replacement if a compatible container is missing.
A fill mark is a limit, not an invitation to pack the contents down. If the container is at its marked limit before the draw, arrange a replacement before proceeding. If you discover that limit with a used sharp already in hand, activate the device feature as directed and use a nearby approved container with capacity, following the facility safety procedure. Avoid recapping, disassembly and hand pressure on used sharps. Record or report missing equipment, a failure of the safety feature or any exposure under the appropriate procedure.
See CSMLS safe work competencies, CCOHS hierarchy of controls, PHAC human diagnostic activities, Canadian Biosafety Standard, third edition, PHAC laboratory equipment guidance, Health Canada biocide application and contact times, Ontario Needle Safety Regulation, CCOHS sharps guidance, BD collection device instructions, AHS community sharps and waste guidance.
A procedure specifies an enclosure which protects personnel, work material and the environment during an approved biological task. Which is designed for that combination?
A product-protection clean bench
An appropriately certified Class II biological safety cabinet
A chemical fume hood selected for solvent vapour
An unventilated open bench
A spill procedure calls for an approved surface disinfectant with a specified wet contact time. What should the trained responder verify?
That the surface can be wiped dry immediately
That any available skin antiseptic can substitute
That expired stock smells like fresh product
That the product is suitable for the surface and applied for the required wet contact time
Before a venous draw, the MLA sees that the point-of-use sharps container has reached its marked fill limit. What is the appropriate response?
Arrange an approved replacement within reach before starting the collection
Press down on the existing contents using a gloved hand
Plan to recap the used needle while looking for another container
Remove the lid and use the remaining space above the line
Sections you finish are checked off in the contents.