13.2 Delegated LIS Result Recording, MLT Validation Prerequisite & Critical/Blood-Product Protocols

Key Takeaways

  • Send results and technical flags to the designated MLT for verification.

  • Record accepted results only when delegated and use the correct approved record.

  • Check patient and accession, test, digits, decimal, units, context and comments against the validated source.

  • Verify authorization and use the local release or information-access pathway.

  • Communicate urgent results and document confirmation according to policy.

Last updated: November 2026

Recording a result is a patient safety task. Under the February 2027 CSMLS competency profile, the MLA can assist with simple results reporting when delegated after the MLT has validated and released the result as acceptable. Submitting a source record for review, recording a validated result and receiving authority to release a report are distinct workflow steps.

Keep the Record Traceable

Under criteria 5.1.1–5.1.3, provide the record to the MLT for verification. Then record an accepted result when delegated, following the laboratory’s procedures and applicable legal requirements. Verify that the entry is accurate, complete and clear. The MLT validates the recorded result before release for reporting. Follow the lab’s established procedure if the instrument sends the result automatically to the laboratory information system (LIS).

Compare with validated sourceWhat to check
IdentityCorrect patient and accession, source or date when required.
ResultExact digits, decimal, inequality sign and any approved qualitative description.
UnitsMatch the reported scale. For example, 4.5 mmol/L and 45 mmol/L are different values.
StatusDistinguish hold, approved result, notification and released report.
Record historyPreserve flags and authorized corrections using the established amendment process.

Suppose the source blood glucose is 4.5 mmol/L and the entry on screen reads 45 mmol/L. The data-entry error multiplies the numerical value by ten. Protect the result from release and follow the correction procedure, including verification. If the wrong value has already been released, promptly notify the designated staff and use the amended-report process rather than overwriting the original without a trace. Ontario’s laboratory regulation, for example, requires the specified record for testing that needed a correction, including the initial and subsequent test results.

Communicate Safely

Do not use a call or message as an informal substitute for the approved release process. Verify who is contacting the laboratory, the required patient identifiers, the requester’s authority and the permitted method for communicating the information. Do not rely on a number supplied by an unverified caller. If authority cannot be established, refer the request to the designated pathway. When a patient asks what a result means, route the question to the authorized clinical team and follow the applicable process for requests for access. Patient access rules depend on the custodian and situation.

A technician may handle a verified administrative step while another professional interprets the result. Follow the approved distinction in the workplace. At Alberta Precision Laboratories, for example, patients can use its formal access instructions. Access and interpretation requests do not authorize release by a worker whose role does not include that function.

Escalate Urgent and Unverified Work

A critical-result threshold is a laboratory-defined trigger for urgent communication. It can vary by test and patient group. If a source printout carries an urgent flag but has not been verified, refer it promptly to the designated MLT. Do not discard the flag or communicate it as a final result. Clinical urgency can require a quick handoff even while a result is held.

When a policy delegates communication of an authorized critical result, use the documented steps for identifying the recipient, verifying the information conveyed and recording what happened. In a telephone read-back process, the recipient repeats the required patient and result information. Compare the read-back with the actual record. Notify the next designated contact if nobody authorized is reachable within the applicable process. Record the time, recipient or attempted contacts, data confirmed and actual disposition. This lets later staff see whether an urgent message was delivered.

For a simulated telephone notification, the authorized source says 4.5 mmol/L, and the recipient reads back 45 mmol/L. Stop the handoff long enough to repeat the correct value and hear a correct read-back. Record the actual contact and confirmation according to the procedure. This closes the loop on the spoken message. When the difference concerns the actual laboratory record, send it back through the authorized correction and verification pathway.

During downtime, follow the approved alternative record and reconciliation procedure. Mark the source accurately and capture the required verification before distributing information. On restoration, reconcile to the proper accession and preserve the record of any urgent call made during the interruption.

See CSMLS criteria 5.1.1 to 5.1.3, BC DAP reporting requirements, Ontario laboratory recordkeeping requirements, Ontario IPC access and correction, APL patient result access policy, University of Toronto laboratory critical result communication recommendations.

Loading diagram...
Verify Before Recording and Communicating
Test Your Knowledge

A preliminary urinalysis printout contains a QC warning. What should the MLA do?

A

Enter the result as final and add a warning comment

B

Communicate the finding as a final clinical result

C

Hold the work and send the source and QC flag to the designated MLT for verification

D

Report whichever repeat reading has no flag without following the QC process

Test Your Knowledge

A validated source value is 4.5 mmol/L, but the draft entry reads 45 mmol/L. What action protects the record?

A

Hold the draft, follow the authorized correction process and verify it against the validated source

B

Approve the entry because the unit matches

C

Change the source sheet to agree with the draft

D

Release the entry and allow the recipient to calculate the correction

Test Your Knowledge

A caller asking for a result provides the patient’s name but the worker cannot verify the caller’s authority. What is the appropriate response?

A

Release it because the name is correct

B

Use the approved authorization or access pathway before any disclosure

C

Send the report to the fax number provided by the caller

D

Ask the caller whether the result sounds familiar