3.3 Timed Collections, Therapeutic Drug Monitoring & Temperature/Light-Sensitive Analytes

Key Takeaways

  • Collect the glucose tolerance baseline before the drink. Follow the lab’s timing anchor for interval specimens and record the actual times.

  • For a drug level labelled trough, use the defined pre-dose window. Peak or other timed levels use the timing specified by the order and procedure.

  • Match temperature and transport to the particular analyte, specimen matrix and receiving laboratory. A blood gas in a plastic syringe often has different handling from chilled ammonia.

  • Cryoglobulins can precipitate during premature cooling. Follow the warm-collection procedure and the specific lab’s centrifugation instructions.

  • Use the specified light protection for bilirubin and other photosensitive analytes while preserving a clear link between the label and the specimen.

Last updated: November 2026

Some orders specify a physiological point in time. Others require transport conditions that preserve the specimen after collection. Check the exact test, matrix, interval, temperature and destination before assembling supplies. Time and handling should be documented so the receiving lab can recognize a deviation.

Glucose Tolerance, Timed Drug Levels and Clock Time

An oral glucose tolerance test (OGTT) measures glucose at specified intervals after a glucose drink. The order and laboratory procedure specify which test is being performed. A screening test can follow different requirements from a diagnostic tolerance test. Ask the patient about actual preparation and verify the fasting requirement against the protocol. Collect the baseline before the drink.

Example. Alberta Precision Laboratories’ instructions for its two-hour test ask the patient to finish the drink within five minutes and schedule the follow-up from when the patient finishes the drink. For a baseline at 08:10, a start at 08:12 and finish at 08:16, the two-hour follow-up is 10:16. Its gestational two-hour instructions also specify a one-hour draw, which would be 09:16. Record the actual collection times and follow the site's procedure for a missed draw or an incomplete drink. A collection performed at 10:12 in this example is four minutes early. The site’s acceptance policy determines how the deviation is handled.

Therapeutic drug monitoring (TDM) uses specimens tied to a dose or defined schedule. A trough sample for a conventional vancomycin order is collected before the next dose. Check the window for that order and confirm times with the nurse. If the dose starts first, tell the team. They can determine whether collection should be rescheduled or the order changed. A peak or random level serves a different clinical purpose and has its own instructions. Document dose and draw times in the required fields. Concentration interpretation and medication changes belong to the clinical team.

A timed instruction can also address normal changes during the day. With an order for morning cortisol, confirm the requested collection time and record the actual time so the result is interpreted with the applicable reference information. The same principle applies to rest and position when a test’s collection instructions specify those conditions.

Cold, Warm and Light-Protected Specimens

ExampleCheck before collectionWhy the check matters
AmmoniaThe Calgary-zone APL collection chart calls for a venous EDTA specimen on ice. Other sites specify their own acceptance and transport details.Concentration can increase after collection. Follow the site's interval and processing procedure.
CryoglobulinsFollow the receiving lab’s requirements for tube, warming, handoff, clotting and processing.Premature cooling can precipitate immunoglobulins before separation, leading to loss in the serum aliquot.
BilirubinUse the required sample matrix and approved light protection, such as an amber carrier in the APL microcollection example.Light exposure can decrease measured bilirubin. Keep traceable identifiers on the specimen itself.
Blood gas in a plastic syringeCheck approved device, transport mode, temperature and analysis time. Alberta Health Services’ South Zone bulletin specifies room temperature for arterial blood gas specimens in plastic syringes.Air exchange and cellular metabolism can alter measurements. Cooling rules for a different tube or syringe cannot be applied here.

The same general handling principle can have different validated workflow details. APL’s Calgary adult cryoglobulin collection log specifies prewarming, warm transport and a 37 °C incubation followed by room-temperature centrifugation. Another receiving lab can specify warmed centrifugation. At handoff, record actual handling and report any time or temperature excursion. If a specimen has cooled before a required warming step, alert the receiving bench so it can apply the specimen policy.

Air and Blood Gases

Arterial and venous blood gases require prompt handling and protection from room air. Use the approved collection device and its procedure for clearing air, closing the syringe and gently mixing the anticoagulant. Collection of an arterial sample requires the training and authorization applicable at the site. A Medical Laboratory Assistant (MLA) may instead receive or transport a specimen collected by an authorized practitioner.

A bubble can move the blood’s gas tensions toward those of the room air. The direction of oxygen error depends on the starting oxygen level. Air exposure can raise a low partial pressure of oxygen and lower a very high one. Carbon dioxide can fall and pH can rise as carbon dioxide leaves the blood. If a bubble is discovered at accession, tell the bench and apply its specimen acceptance rules. Removing the bubble after gas exchange has occurred cannot restore the original sample.

Worked Handoff

At the start of a round, three orders specify ammonia on ice, warmed cryoglobulin collection and light-protected bilirubin. Prepare the three transport conditions before the first collection. Record the start and handoff times and identify any deviation at accession. A generic rack marked “special handling” does not tell the receiver how the three samples travelled. Use the specimen-specific instructions and the laboratory’s label and documentation system.

See APL glucose tolerance instructions, the Saskatoon vancomycin bulletin, APL microcollection requirements, APL cryoglobulin log, AHS blood gas guidance, and the arterial blood gas study.

Test Your Knowledge

Under the lab’s routine pre-dose vancomycin trough protocol, the next dose is scheduled for 10:00. Which collection instruction follows that protocol?

A

Collect the specimen 30 minutes after the IV infusion finishes

B

Collect the specimen immediately before the next scheduled dose is administered

C

Collect the specimen halfway between doses from the IV infusion port

D

Collect the specimen in a gold SST 2 hours after starting the infusion

Test Your Knowledge

Why does the laboratory require warm collection and transport for a cryoglobulin specimen before serum separation?

A

Warming accelerates glycolysis to stabilize immunoglobulin structure

B

Warming prevents ammonium heparin from precipitating fibrinogen

C

Premature cooling can precipitate cryoglobulins, reducing the amount recovered in the serum

D

Cooling activates complement to destroy serum proteins before analysis

Test Your Knowledge

An arterial blood gas syringe has a large air bubble. The patient is receiving supplemental oxygen, and the specimen’s original oxygen tension is higher than that of room air. What can happen?

A

The measured oxygen tension can decrease as oxygen moves from blood into the bubble

B

The measured oxygen tension must increase for every arterial sample

C

Oxygen tension remains correct if the bubble is removed on arrival

D

The air bubble makes the hemoglobin result sufficient to reconstruct oxygen tension

Sections you finish are checked off in the contents.