7.1 Standard Precautions vs. CDC Dialysis-Specific Infection Control Guidelines

Key Takeaways

  • Standard Precautions apply to every patient. The task and likely exposure determine the required personal protective equipment.

  • Gloves and hand hygiene are required for dialysis patient care and contact with the patient’s dialysis equipment. Remove used gloves and clean your hands before moving to another patient or a clean task.

  • Use the designated clean medication preparation area away from individual stations. Deliver each patient’s medication separately and keep station items out of common clean stock.

  • Use compatible cleaning and disinfection procedures for reusable items before sharing them. Discard or dedicate items that cannot be reprocessed for sharing.

  • Apply the CDC dialysis infection-prevention practices as a bundle. Review observations, catheter care, patient education and bloodstream infection surveillance together.

Last updated: November 2026

Quick Answer: Standard Precautions apply regardless of diagnosis. In hemodialysis, additional rules address the regular contact with blood, repeated vascular access and shared treatment space.

Apply the Rules at the Station

The federal hemodialysis infection-control condition, 42 CFR § 494.30, incorporates specified CDC dialysis recommendations. The federal rule excludes the older HCV screening recommendations from that incorporation. Standard Precautions still govern hand hygiene, safe injections, equipment reprocessing, exposure-based PPE, and respiratory hygiene.

DecisionDialysis application
Touch the patient, machine or equipment at the stationUse appropriate gloves for care or contact with the patient’s equipment. Change them before moving to a clean task or another patient and perform hand hygiene. Casual social contact is addressed separately in CMS interpretive guidance.
Bring an item to a stationTreat the item as potentially contaminated. A compatible reusable item may be cleaned and disinfected before use on another patient. Dedicate non-disposable items that cannot be cleaned and disinfected for sharing to a single patient.
Handle unused station supplies or medicationsReserve them for that patient or discard them as appropriate. Supplies or medications taken to the station do not return to common clean stock.
Prepare and transport medicationsUse a designated clean medication area physically separated from individual stations. CMS allows a designated clean area within the treatment area if separated from the stations. Deliver medications separately. A common medication cart cannot be used for preparation or distribution in the treatment area. If trays are used, clean them between patients.
Turn over the treatment stationWait for the patient to leave before starting routine turnover. Remove used items, clean and disinfect appropriate surfaces, and allow the labeled contact time before the next setup. For items visibly contaminated with blood, apply the dialysis-specific intermediate-level disinfection requirement and product instructions.

A glove used to touch the touchscreen, pressure cuff or saline line at one station cannot be used to reach into clean stock. Plan the supply run before starting and bring what one patient needs. Separate used specimens, waste and equipment from medication preparation.

Prevent and Investigate Bloodstream Infections

CDC surveillance shows that hemodialysis patients with CVCs experience a higher reported bloodstream infection risk than patients with fistulas. Access type is one prevention factor. CDC’s dialysis core interventions also include infection surveillance and feedback, hand hygiene observations, vascular access care observations, competency assessment, patient education, reduction of catheter use when feasible, appropriate skin antisepsis, hub disinfection and compatible exit-site antimicrobial care.

In CDC’s outpatient program, review bloodstream infections and other dialysis events each month and share findings with staff. Observe hand hygiene monthly and observe vascular access care quarterly. The access audit includes aseptic connection, disconnection and dressing changes. A falling infection rate and improving technique are different types of evidence. For example, no new positive culture this month does not justify ignoring a contaminated glove touching a disinfected hub. Record the observed step so that staff can correct it and repeat the observation.

During catheter care, use a compatible antiseptic and friction on the hub, let it dry and keep it aseptic. Follow the device and product directions. Exit-site antisepsis and hub care use different instructions. These practices apply every time the catheter is accessed or disconnected.

Worked Scenario: Tracing a Shared-Supply Breach

Three patients using catheters have reported positive blood cultures over two weeks. The supervisor finds a common saline vial taken to multiple stations, tape carried between chairs and inconsistent hub drying.

  1. Remove shared supplies and report the identified breaches through the infection prevention process. Review whether other patients were exposed and clean and disinfect affected surfaces and reusable devices as required.
  2. Observe medication preparation, glove changes and catheter access. Separate the clean preparation area and discontinue shared use of station supplies.
  3. Record organisms, dates, access type and relevant clinical and process data. Work with infection prevention to determine notifications and reporting. A cluster and a breach justify investigation, but alone do not establish one common source.

Sources 42 CFR § 494.30, CMS Appendix H revision 246, V113–V122, CDC core prevention practices, CDC dialysis prevention interventions, CDC core intervention frequencies and CDC surveillance analysis by access type.

Test Your Knowledge

A reusable medication tray from one station is about to be used for medication delivery to another patient. What plan follows dialysis infection-control guidance?

A

Clean the tray between patients and prepare each patient’s medication separately in the designated clean area.

B

Restock unused syringes from the first station and place them on the tray for the second.

C

Move a common medication cart chair to chair and prepare each injection on the cart.

D

Reuse the tray without cleaning when supplies were wrapped.

Test Your Knowledge

Which access type was associated with the highest rate of Staphylococcus aureus bloodstream infections in the CDC’s national dialysis surveillance analysis?

A

Native fistula.

B

The analysis found equal rates for every access.

C

Central venous catheter.

D

Graft or other access.

Test Your Knowledge

After cleaning a catheter hub with the appropriate antiseptic, the technician notices that the hub is still wet. What should the technician do?

A

Wipe the hub dry with a used gauze pad.

B

Let it air-dry per the product instructions while keeping it aseptic.

C

Attach the dialysis bloodline while the hub is still wet.

D

Touch the hub to a clean glove to check if it has dried.

Sections you finish are checked off in the contents.