4.2 Central Venous Catheter Care: Aseptic Dressing Change, Exit-Site Inspection, and Locking Protocols

Key Takeaways

  • Inspect the catheter, exit site and dressing before connection. Report drainage, tenderness along the tunnel, new displacement or poor catheter function.

  • Use hand hygiene and aseptic hub and exit-site care. Follow the facility’s PPE rules and the compatible antiseptic instructions for friction and drying.

  • Verify the ordered lock, concentration and volume separately for each lumen. Follow the product and device instructions for instillation and withdrawal.

  • Poor blood return alone does not establish a fibrin sheath. Do not force the catheter. Report the finding and follow the authorized plan.

Last updated: November 2026

Quick Answer: Keep catheter hubs aseptic whenever opening or reconnecting the system. Check the exit site and lock order, and raise any signs of infection, migration or poor flow before using the catheter.

Inspect and Dress the Exit Site

Assess the dressing, exposed catheter and surrounding skin. Report new redness, tenderness, swelling or drainage. Tenderness or redness extending along the tunnel raises concern for a deeper infection. A newly visible cuff, torn catheter or changed external length warrants assessment before use. Keep the catheter secured and notify the nurse. Moving exposed catheter material back into the tunnel risks contamination.

  • Perform hand hygiene and use PPE specified for the task and anticipated exposure. Use aseptic technique to remove and replace the dressing, change gloves and repeat hand hygiene when moving from the old dressing to site care. KDOQI considers masks for both patient and staff reasonable for connection and disconnection. The CDC exit-site checklist directs staff to wear a mask when required.
  • For dressing changes, CDC recommends an alcohol-based chlorhexidine product above 0.5% as first line, with compatible alternatives when chlorhexidine is not tolerated. Apply friction and let the site dry according to the chosen product and policy. Protect the prepared site from contact. Verify compatibility before applying any ordered exit-site ointment or antimicrobial dressing.
  • Use an approved sterile gauze or transparent semipermeable dressing. Gauze is preferred for an oozing site. Replace a dressing that has become damp, loose or soiled. KDOQI advises changing dressings at least weekly, with frequency adjusted for the condition of the site and clinical judgment. Document the site findings, care and notifications.

Protect the Hubs and Manage the Ordered Lock

StageCheck and action
Before openingVerify the patient, treatment and catheter orders. Perform hand hygiene, don new gloves and verify the catheter is clamped before removing the cap. Keep the hub open only as long as necessary and use the aseptic procedure for its connector.
At connection and disconnectionScrub the threads and hub end with friction, using a separate compatible antiseptic pad for each lumen. Let the antiseptic dry and protect the cleaned ends from contact. For a closed needleless connector, follow its instructions.
Removing the previous lockVerify the agent and use its prescribed withdrawal and discard requirements. For example, the U.S. DefenCath label requires aspiration and discard before the next dialysis. If you cannot withdraw the lock as directed, stop and notify the nurse.
After treatmentAfter rinseback and aseptic disconnection, complete the ordered flush and instill the prescribed catheter lock using the catheter and product instructions. Check the intended volume for each lumen and secure the sterile caps and clamps. Document the lock and any problem.

Heparin and low-concentration citrate are examples of lock agents considered in KDOQI guidance. The order defines which product to use. Heparin can expose the patient to systemic anticoagulation if excess enters the circulation. The lock concentration and volume are separate checks. If the prescribed volumes are 1.6 mL and 1.8 mL, the combined volume is 3.4 mL but each lumen still receives its own specified volume.

Worked Case: Withdrawal Lumen Will Not Aspirate

The return lumen has blood return, but the withdrawal lumen does not aspirate after a preconnection check. Report the affected lumen and examine external factors such as clamp position and kinking within your role. A tip against the vessel wall, thrombus or a fibrin sheath can affect function. An apparently easy flush would not prove the cause. Refer the problem to the nurse before proceeding.

KDOQI assesses dysfunction against the blood flow needed to deliver adequate dialysis in the scheduled treatment time. An ordered intraluminal thrombolytic is one clinician-directed option when thrombus is suspected. The drug order and protocol define the dose, volume, method, assessment and disposal. A lumen’s printed volume for routine lock verification does not, on its own, determine an alteplase dose.

Sources CDC dialysis bloodstream infection prevention, CDC exit-site checklist, CDC scrub-the-hub protocol, CDC dressing recommendations, KDOQI vascular access, §§ 11 and 20–23, DefenCath U.S. labeling and Cathflo U.S. labeling.

Test Your Knowledge

A patient arrives with a damp transparent catheter dressing. The site is due for routine care tomorrow. What should the technologist do?

A

Wait for the scheduled change if the dressing is transparent.

B

Follow the facility’s aseptic replacement procedure and inspect the site.

C

Add a layer of tape and leave the wet dressing in place.

D

Remove the dressing and leave the site uncovered during treatment.

Test Your Knowledge

The order confirms that the previous session used DefenCath. How does its labeling direct staff to handle the existing lock before the next hemodialysis session?

A

Flush it into the patient rapidly with saline.

B

Instill an extra amount to displace it into the circulation.

C

Aspirate and discard the existing lock.

D

Leave it in the lumen when connecting the dialysis bloodline.

Test Your Knowledge

A tunneled catheter has poor blood return. Its lumen is marked 1.6 mL, and an alteplase order needs clarification about the dose and volume. What should the technologist do?

A

Report the problem and clarify the order with the nurse before any instillation.

B

Use 1.6 mL of any available thrombolytic as a default.

C

Use a smaller syringe to force blood return first.

D

Assume a fibrin sheath is confirmed and administer a double dose.