8.3 Environmental Disinfection: Routine Turnover, Blood Spills, and Bleach Dilutions
Key Takeaways
Disinfect the station after the patient leaves. Keep clean equipment and the next patient away until turnover is complete.
For visible blood in a hemodialysis station, use the facility’s approved intermediate-level procedure and compatible products. Routine low-level disinfection can be appropriate for compatible surfaces without visible blood.
Use the product’s label for dilution and wet contact time. A dilution such as 1:100 or 1:10 also depends on the labeled stock strength.
When a spill occurs during treatment, call for help and protect the patient first. Then handle the contaminated surfaces and sharps using the exposure-control procedure.
Use workplace labeling and safety data sheet instructions. Never mix bleach with acid, ammonia or another cleaner.
Quick Answer: After the station is empty, follow the routine turnover procedure. Visible blood requires the dialysis blood-contamination procedure, including the appropriate intermediate-level disinfection. The selected product and surface determine dilution, wet contact time and other handling.
Choose the Procedure by the Surface
| Situation | Procedure |
|---|---|
| Routine turnover, no visible blood or soil | Use the facility’s approved compatible product. CMS Appendix H lists low-level disinfection for environmental surfaces including the exterior of hemodialysis machines in this situation. |
| Visible blood or a gross blood spill | Protect staff and patients, remove contamination safely and use the dialysis-required intermediate-level procedure. Choose surface-compatible products and follow their instructions. |
| Blood has entered or may have entered a machine housing or internal pathway | Isolate equipment as appropriate, report the problem and use the manufacturer’s and facility’s internal contamination procedures. An exterior surface wipe cannot address an internal exposure. |
| Reusable noncritical equipment such as a compatible cuff | Clean and disinfect between patients, choosing the appropriate level for visible blood and the equipment instructions. A cloth or other item that cannot be adequately disinfected is dedicated or handled per policy. |
Clear the station of used supplies according to policy and empty the prime-waste container. After the patient leaves, use appropriate gloves and disinfect the surfaces and container according to the product and equipment instructions. Apply with friction where indicated and keep each surface visibly wet for the full labeled contact time. Complete any drying or other finishing steps before taking clean supplies to the station.
Apply and Check the Prescribed Dilution
CDC environmental guidance includes examples for bleach when it is selected for a compatible nonporous surface. It describes a 1:100 dilution after cleaning a small blood spill, and 1:10 as an initial application before cleaning a large spill under that guidance. The first application is part of a spill procedure and does not replace removing visible soil and performing final disinfection. The facility selects a product and procedure compatible with its equipment. The label specifies the applicable wet contact time.
For a calculation, assume a stock specified as 60,000 ppm available chlorine and final volumes that add as measured. One part stock in 100 total parts has ppm. One part in 10 total parts has ppm. For a 1 L final volume at 1:100, mL is stock in a total of 1,000 mL. Verify actual stock concentration, the product instructions and approved preparation and expiry before making a solution. Part-to-total notation differs from part-to-water notation.
Manage a Spill and Protect the Next Patient
- Address the patient and circuit. If blood is escaping during treatment, call for help and control the source under the emergency procedure. Keep others away from the spill area.
- Use exposure-based PPE and the spill kit. Follow the written procedure for containment, safe removal of visible blood and disinfection. Use mechanical tools for contaminated broken glass. Dispose of materials under the exposure-control plan and applicable requirements.
- Respect the materials and the label. Use the required wet contact time on each compatible surface. Never mix disinfectants, including bleach with acid or ammonia. Store chemicals and label workplace containers under the safety data sheet, OSHA rules and facility procedure. OSHA has a narrow exception for a portable container intended only for immediate use by the employee who made the transfer. A shared bottle kept for later use needs workplace labeling.
Worked Scenario: One Spill, Two Surfaces
After patient care is secured, staff identify blood on the floor and along a machine door seam. The floor is compatible with the approved spill product. That product is not listed for the machine surface. Staff use the approved floor procedure and keep the machine out of use while reporting the possible internal contamination for qualified assessment. Putting a stronger product on the exterior would not address the blood that may have entered the machine.
Sources CMS Appendix H revision 246, V122–V123, CDC routine dialysis station checklist, CDC environmental recommendations for blood spills, EPA disinfectant label and contact-time directions, OSHA bloodborne pathogens, OSHA Hazard Communication and NIOSH disinfectant chemical safety.
An approved procedure specifies a 1:100 dilution, defined as one part stock in 100 total parts. The stock is 60,000 ppm available chlorine. What is the nominal diluted concentration?
600 ppm.
6,000 ppm.
60 ppm.
59,400 ppm.
The patient is safe and the source of a blood spill has been controlled. Visible blood remains on a nonporous dialysis station surface. What is the appropriate plan?
Turn the station over with the routine no-visible-blood procedure.
Apply any product for 10 minutes, regardless of its label or equipment compatibility.
Wipe with dry towels and immediately set up for the next patient.
Follow the approved spill procedure with appropriate PPE, safe soil removal and compatible intermediate-level disinfection for its labeled contact time.
A technician prepares a workplace disinfectant bottle for several employees to use throughout the shift. Which labeling principle applies?
No label is needed because the employees recognize the bottle.
The immediate-use exception applies whenever the contents are used up before the next shift.
Use the required workplace label and follow the product and facility directions for storage and expiry.
Use a full 24-hour expiry and handwritten initials as a substitute for required hazard information.
Sections you finish are checked off in the contents.