PracticeVideosBlogFlashcards
Cheat sheet

PRC Radiologic Technologists Licensure Exam Cheat Sheet

Radiologic Physics, Equipment, Biology, Protection

20%of exam

Image Production and Evaluation

20%of exam

Radiographic Positioning and Radiologic Procedures

20%of exam

Patient Care and Management

20%of exam

R.A. 7431 Law & JurisprudencePatient Care & EmergenciesAnatomy & TerminologyInfection Prevention

Radiological Sciences

20%of exam

Quick Facts

Official Exam Items
500 across five 100-item subjects
Subject Weight
20% each
2026 Exam Dates
December 10–11
Session Time
150 minutes per subject
Total Session Time
12.5 hours; breaks excluded
Passing Ratings
Average ≥75%; each subject ≥60%
Complete Exam Fee
P900
Removal Exam Fee
P450
Educational Route
Recognized BSRT degree

Photoelectric and Compton Interactions

Photoelectric

  • Incident photon absorbed
  • Bound electron ejected
  • Strong atomic-number dependence

Compton

  • Photon retains part of energy
  • Photon changes direction
  • Scatter can reduce image contrast

Absorption differs from partial-energy scattering

X-Ray Physics & Generators

Tungsten Target
Atomic number 74; K-binding ≈69.5 keV
Bremsstrahlung
Electron braking; continuous photon spectrum
Characteristic Emission
Shell vacancy filled; discrete photon energy
Photoelectric Effect
Photon absorbed; bound electron ejected
Compton Scatter
Photon redirected; some energy transferred
Anode Heel Effect
Cathode-side intensity generally greater
HVL
Specified absorber halves narrow-beam air kerma
Added Filtration
Harder beam; lower output
Generator Ripple
Lower ripple generally increases output

Tissue Reactions and Stochastic Effects

Tissue Reactions

  • Endpoint-dependent threshold
  • Severity generally rises with dose
  • Example: sufficiently severe skin injury

Stochastic Effects

  • Probability is the protection concern
  • Severity not predicted by dose
  • Low-dose risk uses protective models

Threshold injury differs from probabilistic risk

Radiobiology & Dose Limits

Radiosensitivity
Cell type, endpoint and dose matter
Lymphocytes
Apoptosis challenges simple division-rate rule
Tissue Reactions
Threshold depends on endpoint and conditions
Stochastic Effects
Probability modeled; severity not dose-scaled
Fetal Exposure
Assess dose and developmental stage
PNRI Adult Effective Dose
20mSv/year averaged over five years
PNRI Adult Lens Dose
20mSv/year averaged over five years
PNRI Single-Year Maximum
50 mSv effective and lens doses
PNRI Skin and Extremities
500 mSv/year adult occupational limit
PNRI Scope
Radioactive-material practices; excludes DOH-FDA X-rays

Quality Assurance & Informatics

QA
Organized process for reliable imaging
QC
Measurements checking equipment and process performance
DICOM
Image information and communication standard
PACS
Image storage, retrieval and distribution system
Image Privacy
Check pixels and identifying metadata
Repeat Analysis
Identify causes; improve acquisition process
Dose Indicators
Interpret with image quality and context

Exposure Calculation Checks

Units → Assumptions → Formula → Result

Use consistent distance unitsGrid factor must be supplied15% rule is approximateDI describes index versus target

CR and Direct DR Signal Conversion

CR

  • Storage phosphor latent signal
  • Laser readout releases light
  • Plate requires appropriate erasure

Direct DR

  • Photoconductor creates charge
  • Electronic detector readout
  • No scintillator light-conversion stage

Conversion pathway cannot guarantee image superiority

Technique & Grid Picker

  1. Higher kVp proposed→Apply validated technique; assess contrast(15% rule is approximate)
  2. Grid factor explicitly supplied→Multiply original mAs by factor(Ratio alone does not specify factor)
  3. Focused-grid peripheral cutoff→Check orientation, centering, level and SID(Do not merely raise exposure)
  4. Exposure index differs from target→Assess segmentation, technique and image quality(Not automatic repeat)
  5. Film control strip has shifted→Investigate processing against QC baseline(Do not compensate through patient exposure)

Exposure Math & Grids

Inverse Square
I₂ = I₁ × (d₁/d₂)²
Point-Source Example
160µGy at 1m → 40µGy/2m
Approximate 15% Rule
80kVp/20mAs → 92kVp/10mAs
Distance Compensation
mAs₂ = mAs₁ × (SID₂/SID₁)²
SID Example
10mAs/100cm → 32.4mAs/180cm
Specified Bucky Factor 5
5mAs without grid → 25mAs
Magnification
SID ÷ SOD
Geometric Unsharpness
Focal-spot size × OID/SOD
Focused Grid Cutoff
Check orientation, alignment and focal range

Film, CR, DR & Displays

Film Development
Exposed crystals become metallic silver
Film Fixation
Removes remaining unexposed silver halide
Film QC
Compare sensitometry with established baseline
CR
Laser stimulates stored phosphor signal
Indirect DR
Scintillator light → electrical charge
Direct DR
Photoconductor converts X-rays to charge
Nyquist Frequency
1 ÷ (2 × sampling pitch)
100µm Pitch
Nyquist 5lp/mm; not measured resolution
IEC Deviation Index
10 log₁₀(EI/EIₜ)
DI +3
Exposure index approximately twice target
Window Width
Adjusts displayed intensity range
Window Level
Adjusts displayed range centre

Towne Baseline Relationship

OML thirty; IOML thirty-seven

Angles relative to named baselineAbout seven degrees differenceDo not force injured neck

Cervical and Lumbar Oblique Targets

Cervical

  • Intervertebral foramina emphasized
  • Rotation changes demonstrated side
  • Avoid routine rotation in uncleared trauma

Lumbar

  • Zygapophyseal joints emphasized
  • Obliquity changes joint demonstration
  • Use only when clinically indicated

Different targets require different positioning logic

Positioning & Trauma Picker

  1. Decubitus fluid demonstration indicated→Place fluid side dependent if safe(Horizontal beam)
  2. Decubitus pneumothorax demonstration indicated→Place affected side elevated if safe(Horizontal beam)
  3. Free-air study; cannot safely stand→Use prescribed safe decubitus adaptation(No forced waiting in instability)
  4. Suspected neck or hip fracture→Preserve precautions; adapt or escalate imaging(No forced rotation)
  5. Suspected GI perforation→Radiologist selects appropriate initial water-soluble agent(Consider aspiration risk)

Skull, Sinus & Spine Views

Towne with OML
30° caudal to OML
Towne with IOML
37° caudal to IOML
Caldwell Routine Geometry
15° caudal PA axial projection
Waters Routine Geometry
OML about 37° to detector
Sinus Fluid Levels
Use appropriate horizontal-beam geometry
Suspected Cervical Injury
Preserve precautions; avoid forced movement
Cervical Obliques
Foramina; unsafe routine rotation in trauma
Lumbar Obliques
Zygapophyseal joints; assess clinical indication

Chest, Abdomen & Extremities

PA Chest
Less heart magnification than comparable AP
Decubitus Pleural Fluid
Dependent side demonstrates layering fluid
Decubitus Pneumothorax
Elevated affected side demonstrates free gas
Left Decubitus Abdomen
Free gas adjacent to liver
Grashey
Open glenohumeral joint space
Scapular Y
Profile scapula; assess humeral-head relationship
Gaynor-Hart
Tangential carpal canal; avoid forced extension
Judet Iliac Oblique
Posterior column and anterior wall
Judet Obturator Oblique
Anterior column and posterior wall
Ankle Mortise
Approximate 15–20° internal limb rotation

Mammography & Contrast Procedures

CC and MLO
Complementary breast tissue demonstration
Compression
Reduce thickness and motion; individualized technique
US MQSA Phantom Dose
≤3mGy per standard-phantom CC exposure
Phantom Dose Benchmark
Not universal patient-dose ceiling
Suspected GI Leak
Usually begin appropriate water-soluble study
Aspiration Risk
Avoid unsuitable hyperosmolar enteric agents
Negative Initial Leak Study
Radiologist selects further imaging if needed
Dental Paralleling Principle
Receptor parallel to tooth; beam perpendicular

RA 7431 Board Composition

Three technologists; one radiologist; one physicist

Five members totalChair among three technologistsProfessional qualifications also required

Radiologic and X-Ray Technology Routes

Radiologic Technologist

  • Recognized BSRT educational route
  • Separate professional registration
  • Five-subject enhanced RTLE blueprint

X-Ray Technologist

  • Recognized associate-diploma educational route
  • Separate professional registration
  • Different examination and result cohort

Keep qualifications and pass rates separate

R.A. 7431 Law & Jurisprudence

RTLE Degree
Recognized Bachelor of Radiologic Technology
Professional Practice
Degree alone does not confer registration
Board Composition
Three technologists; radiologist; medical physicist
Board Minimum Age
30 years at appointment
Passing Average
At least 75% weighted average
Subject Minimum
No subject below 60%
Conditioned Reexamination
Qualifying candidates repeat deficient subjects
Removal Rating
At least 75% each repeated subject
Privacy
Lawful purpose; proportionate information sharing

Vasovagal and Allergic-Like Clues

Vasovagal Pattern

  • Hypotension with bradycardia may occur
  • Pallor and sweating may occur
  • Assess overall presentation and evolution

Allergic-Like Pattern

  • Airway or skin signs may occur
  • Hypotension can be severe
  • Heart rate alone cannot exclude

Emergency assessment overrides a pulse mnemonic

Patient Care & Emergencies

Patient Identity
Reconcile identifiers, order, anatomy and side
Unclear Examination Request
Clarify before exposure
Transfer Safety
Assess mobility, precautions, lines and assistance
Standard Precautions
Apply to all patients
Airborne Precautions
Additional controls for pulmonary tuberculosis
Reaction Assessment
Airway, breathing and circulation; summon help
Adult CPR Rate
100–120 compressions per minute
Adult CPR Depth
At least 5cm; avoid >6cm
Conventional Adult CPR
30 compressions : 2 breaths

Four Radiotherapy Rs

Repair; Redistribution; Reoxygenation; Repopulation

Repair of sublethal damageRedistribution through cell cycleReoxygenation of hypoxic tumor cellsTumor repopulation can oppose control

Conventional Spin-Echo T1 and T2

T1 Weighting

  • Relatively short TR and TE
  • Longitudinal relaxation contrast
  • Simple fluid usually relatively dark

T2 Weighting

  • Relatively long TR and TE
  • Transverse relaxation contrast
  • Simple fluid usually relatively bright

Sequence modifications can change signal appearance

Contrast & Emergency Picker

  1. Severe symptoms during contrast injection→Stop; summon response; assess ABC(Follow trained emergency protocol)
  2. Extravasation suspected→Stop injection; obtain clinical examination(Assess perfusion, sensation and movement)
  3. Severe/progressive extravasation symptoms→Obtain urgent surgical assessment(Do not use volume alone)
  4. IV contrast; no AKI; eGFR≥30→ACR: metformin need not stop(Local policy/label may differ)
  5. AKI/eGFR<30 or renal-embolic arterial study→Hold metformin; reassess after 48h(Authorized restart decision)
  6. Potential penetrating orbital ferromagnetic injury→Radiograph or review suitable prior CT(Metalworking alone is not indication)

CT & MRI Physics

Helical Pitch
Travel/rotation ÷ nominal beam width
Pitch-Dose Relationship
Inverse only with other settings fixed
Water CT Number
Approximately 0 HU
Air CT Number
Approximately −1000 HU
CTDIvol
Standardized phantom-based scanner-output index
DLP Example
10mGy × 30cm = 300mGy·cm
Proton Frequency
42.58 MHz/T × field strength
1.5T / 3T Protons
Approximately 63.87 / 127.74 MHz
MR Zone III
Controlled access under Level-2 MR supervision
ACR 2026 B₀ Hazard Area
Within 9-gauss line; mapped spatially
Orbital Trauma Concern
Evaluate suspected penetrating ferromagnetic foreign body

Modality Physics Picker

  1. GBCA needed; CKD4/5→Use group II; avoid group I(Supervising clinician assesses benefit and risk)
  2. Bolus specified in therapy plan→Verify material, position and planned use(No independent treatment alteration)
  3. C-arm geometry can be optimized→Under-table tube; close receptor where feasible(Use shielding and appropriate exposure settings)
  4. 5Gy reference air kerma reached→Activate local follow-up process(Not measured peak skin dose)
  5. Tc-99m generator eluate prepared→Check radionuclidic and chemical purity(Use product limits and administration time)

Ultrasound, Nuclear Med & Therapy

Ultrasound Assumed Speed
1540 m/s in soft tissue
Ultrasound Output
ALARA; indication-specific mode and duration
Tc-99m Photon
Approximately 140 keV
Tc-99m Half-Life
Approximately six hours
TECHNELITE Mo-99 Limit
≤0.15 µCi/mCi Tc-99m at administration
TECHNELITE Aluminum Limit
≤10 µg/mL before administration
PET Annihilation
Approximately 511keV paired photons
20% Window at 140keV
126–154keV: ±10% about centre
Therapy Fractionation
Repair, redistribution, reoxygenation, repopulation
Tumor Repopulation
Can oppose treatment control
Bolus
Use only as specified in plan
Fluoroscopy Follow-Up Triggers
3Gy skin; 5Gy reference air kerma

Contrast, Renal Labs & Extravasation

Metformin: IV, No AKI, eGFR≥30
ACR: no routine interruption
Metformin: AKI or eGFR<30
Withhold; 48h; reassess before restarting
Arterial Renal Embolic Risk
ACR metformin withholding also applies
Gadolinium: CKD4/5
Avoid group I; use group II
Known or Suspected AKI
Group II preferred when GBCA needed
Extravasation
Stop injection; obtain clinical assessment
Initial Limb Care
Elevate; initially apply cold compresses
Surgical Referral
Severe/progressive symptoms; not volume alone
Routine Extravasation Aspiration
Not recommended by ACR
Contrast Warming
Not routinely supported for lower-viscosity agents

Common Traps

Dose Metric

Reference air kerma ≠ Peak skin absorbed dose

Rating Versus Raw Count

Official weighted rating ≠ Unvalidated number-correct conversion

Grid Specification

Grid geometric ratio ≠ Exposure multiplication factor

Detector Versus Patient

Detector exposure index ≠ Patient organ absorbed dose

Renal Contrast Groups

Group I gadolinium agents ≠ Group II gadolinium agents

MR Safety Geometry

Mapped magnetic-field contour ≠ Scanner-room physical wall

Warming Evidence

Lower-viscosity contrast agents ≠ Higher-viscosity contrast agents

Film and Digital Appearance

Film optical density ≠ Processed digital display brightness

Last Minute

  1. 1.500 items; five equally weighted subjects
  2. 2.Five sessions ×150min =750min
  3. 3.Pass average ≥75%; subjects ≥60%
  4. 4.Board has five specified professionals
  5. 5.Current PNRI lens: 20mSv five-year average
  6. 6.PNRI excludes DOH-FDA X-ray sources
  7. 7.Formula assumptions precede numerical substitution
  8. 8.Focused grids require correct geometry
  9. 9.Do not force injured joint movement
  10. 10.Metformin decision includes AKI and route
  11. 11.Gadolinium decision includes agent group
  12. 12.Extravasation referral follows clinical severity
  13. 13.MR safety includes implants and fields
  14. 14.Mammography phantom limit is not patient-limit
  15. 15.Follow-up trigger is not confirmed injury
Same family resources

Explore More Philippines PRC Health Exams

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.