Radiologic Physics, Equipment, Biology, Protection
20%of exam
Image Production and Evaluation
20%of exam
Radiographic Positioning and Radiologic Procedures
20%of exam
Patient Care and Management
20%of exam
Radiological Sciences
20%of exam
Quick Facts
- Official Exam Items
- 500 across five 100-item subjects
- Subject Weight
- 20% each
- 2026 Exam Dates
- December 10–11
- Session Time
- 150 minutes per subject
- Total Session Time
- 12.5 hours; breaks excluded
- Passing Ratings
- Average ≥75%; each subject ≥60%
- Complete Exam Fee
- P900
- Removal Exam Fee
- P450
- Educational Route
- Recognized BSRT degree
Photoelectric and Compton Interactions
Photoelectric
- Incident photon absorbed
- Bound electron ejected
- Strong atomic-number dependence
Compton
- Photon retains part of energy
- Photon changes direction
- Scatter can reduce image contrast
Absorption differs from partial-energy scattering
X-Ray Physics & Generators
- Tungsten Target
- Atomic number 74; K-binding ≈69.5 keV
- Bremsstrahlung
- Electron braking; continuous photon spectrum
- Characteristic Emission
- Shell vacancy filled; discrete photon energy
- Photoelectric Effect
- Photon absorbed; bound electron ejected
- Compton Scatter
- Photon redirected; some energy transferred
- Anode Heel Effect
- Cathode-side intensity generally greater
- HVL
- Specified absorber halves narrow-beam air kerma
- Added Filtration
- Harder beam; lower output
- Generator Ripple
- Lower ripple generally increases output
Tissue Reactions and Stochastic Effects
Tissue Reactions
- Endpoint-dependent threshold
- Severity generally rises with dose
- Example: sufficiently severe skin injury
Stochastic Effects
- Probability is the protection concern
- Severity not predicted by dose
- Low-dose risk uses protective models
Threshold injury differs from probabilistic risk
Radiobiology & Dose Limits
- Radiosensitivity
- Cell type, endpoint and dose matter
- Lymphocytes
- Apoptosis challenges simple division-rate rule
- Tissue Reactions
- Threshold depends on endpoint and conditions
- Stochastic Effects
- Probability modeled; severity not dose-scaled
- Fetal Exposure
- Assess dose and developmental stage
- PNRI Adult Effective Dose
- 20mSv/year averaged over five years
- PNRI Adult Lens Dose
- 20mSv/year averaged over five years
- PNRI Single-Year Maximum
- 50 mSv effective and lens doses
- PNRI Skin and Extremities
- 500 mSv/year adult occupational limit
- PNRI Scope
- Radioactive-material practices; excludes DOH-FDA X-rays
Quality Assurance & Informatics
- QA
- Organized process for reliable imaging
- QC
- Measurements checking equipment and process performance
- DICOM
- Image information and communication standard
- PACS
- Image storage, retrieval and distribution system
- Image Privacy
- Check pixels and identifying metadata
- Repeat Analysis
- Identify causes; improve acquisition process
- Dose Indicators
- Interpret with image quality and context
Exposure Calculation Checks
Units → Assumptions → Formula → Result
CR and Direct DR Signal Conversion
CR
- Storage phosphor latent signal
- Laser readout releases light
- Plate requires appropriate erasure
Direct DR
- Photoconductor creates charge
- Electronic detector readout
- No scintillator light-conversion stage
Conversion pathway cannot guarantee image superiority
Technique & Grid Picker
- Higher kVp proposed→Apply validated technique; assess contrast(15% rule is approximate)
- Grid factor explicitly supplied→Multiply original mAs by factor(Ratio alone does not specify factor)
- Focused-grid peripheral cutoff→Check orientation, centering, level and SID(Do not merely raise exposure)
- Exposure index differs from target→Assess segmentation, technique and image quality(Not automatic repeat)
- Film control strip has shifted→Investigate processing against QC baseline(Do not compensate through patient exposure)
Exposure Math & Grids
- Inverse Square
- I₂ = I₁ × (d₁/d₂)²
- Point-Source Example
- 160µGy at 1m → 40µGy/2m
- Approximate 15% Rule
- 80kVp/20mAs → 92kVp/10mAs
- Distance Compensation
- mAs₂ = mAs₁ × (SID₂/SID₁)²
- SID Example
- 10mAs/100cm → 32.4mAs/180cm
- Specified Bucky Factor 5
- 5mAs without grid → 25mAs
- Magnification
- SID ÷ SOD
- Geometric Unsharpness
- Focal-spot size × OID/SOD
- Focused Grid Cutoff
- Check orientation, alignment and focal range
Film, CR, DR & Displays
- Film Development
- Exposed crystals become metallic silver
- Film Fixation
- Removes remaining unexposed silver halide
- Film QC
- Compare sensitometry with established baseline
- CR
- Laser stimulates stored phosphor signal
- Indirect DR
- Scintillator light → electrical charge
- Direct DR
- Photoconductor converts X-rays to charge
- Nyquist Frequency
- 1 ÷ (2 × sampling pitch)
- 100µm Pitch
- Nyquist 5lp/mm; not measured resolution
- IEC Deviation Index
- 10 log₁₀(EI/EIₜ)
- DI +3
- Exposure index approximately twice target
- Window Width
- Adjusts displayed intensity range
- Window Level
- Adjusts displayed range centre
Towne Baseline Relationship
OML thirty; IOML thirty-seven
Cervical and Lumbar Oblique Targets
Cervical
- Intervertebral foramina emphasized
- Rotation changes demonstrated side
- Avoid routine rotation in uncleared trauma
Lumbar
- Zygapophyseal joints emphasized
- Obliquity changes joint demonstration
- Use only when clinically indicated
Different targets require different positioning logic
Positioning & Trauma Picker
- Decubitus fluid demonstration indicated→Place fluid side dependent if safe(Horizontal beam)
- Decubitus pneumothorax demonstration indicated→Place affected side elevated if safe(Horizontal beam)
- Free-air study; cannot safely stand→Use prescribed safe decubitus adaptation(No forced waiting in instability)
- Suspected neck or hip fracture→Preserve precautions; adapt or escalate imaging(No forced rotation)
- Suspected GI perforation→Radiologist selects appropriate initial water-soluble agent(Consider aspiration risk)
Skull, Sinus & Spine Views
- Towne with OML
- 30° caudal to OML
- Towne with IOML
- 37° caudal to IOML
- Caldwell Routine Geometry
- 15° caudal PA axial projection
- Waters Routine Geometry
- OML about 37° to detector
- Sinus Fluid Levels
- Use appropriate horizontal-beam geometry
- Suspected Cervical Injury
- Preserve precautions; avoid forced movement
- Cervical Obliques
- Foramina; unsafe routine rotation in trauma
- Lumbar Obliques
- Zygapophyseal joints; assess clinical indication
Chest, Abdomen & Extremities
- PA Chest
- Less heart magnification than comparable AP
- Decubitus Pleural Fluid
- Dependent side demonstrates layering fluid
- Decubitus Pneumothorax
- Elevated affected side demonstrates free gas
- Left Decubitus Abdomen
- Free gas adjacent to liver
- Grashey
- Open glenohumeral joint space
- Scapular Y
- Profile scapula; assess humeral-head relationship
- Gaynor-Hart
- Tangential carpal canal; avoid forced extension
- Judet Iliac Oblique
- Posterior column and anterior wall
- Judet Obturator Oblique
- Anterior column and posterior wall
- Ankle Mortise
- Approximate 15–20° internal limb rotation
Mammography & Contrast Procedures
- CC and MLO
- Complementary breast tissue demonstration
- Compression
- Reduce thickness and motion; individualized technique
- US MQSA Phantom Dose
- ≤3mGy per standard-phantom CC exposure
- Phantom Dose Benchmark
- Not universal patient-dose ceiling
- Suspected GI Leak
- Usually begin appropriate water-soluble study
- Aspiration Risk
- Avoid unsuitable hyperosmolar enteric agents
- Negative Initial Leak Study
- Radiologist selects further imaging if needed
- Dental Paralleling Principle
- Receptor parallel to tooth; beam perpendicular
RA 7431 Board Composition
Three technologists; one radiologist; one physicist
Radiologic and X-Ray Technology Routes
Radiologic Technologist
- Recognized BSRT educational route
- Separate professional registration
- Five-subject enhanced RTLE blueprint
X-Ray Technologist
- Recognized associate-diploma educational route
- Separate professional registration
- Different examination and result cohort
Keep qualifications and pass rates separate
R.A. 7431 Law & Jurisprudence
- RTLE Degree
- Recognized Bachelor of Radiologic Technology
- Professional Practice
- Degree alone does not confer registration
- Board Composition
- Three technologists; radiologist; medical physicist
- Board Minimum Age
- 30 years at appointment
- Passing Average
- At least 75% weighted average
- Subject Minimum
- No subject below 60%
- Conditioned Reexamination
- Qualifying candidates repeat deficient subjects
- Removal Rating
- At least 75% each repeated subject
- Privacy
- Lawful purpose; proportionate information sharing
Vasovagal and Allergic-Like Clues
Vasovagal Pattern
- Hypotension with bradycardia may occur
- Pallor and sweating may occur
- Assess overall presentation and evolution
Allergic-Like Pattern
- Airway or skin signs may occur
- Hypotension can be severe
- Heart rate alone cannot exclude
Emergency assessment overrides a pulse mnemonic
Patient Care & Emergencies
- Patient Identity
- Reconcile identifiers, order, anatomy and side
- Unclear Examination Request
- Clarify before exposure
- Transfer Safety
- Assess mobility, precautions, lines and assistance
- Standard Precautions
- Apply to all patients
- Airborne Precautions
- Additional controls for pulmonary tuberculosis
- Reaction Assessment
- Airway, breathing and circulation; summon help
- Adult CPR Rate
- 100–120 compressions per minute
- Adult CPR Depth
- At least 5cm; avoid >6cm
- Conventional Adult CPR
- 30 compressions : 2 breaths
Four Radiotherapy Rs
Repair; Redistribution; Reoxygenation; Repopulation
Conventional Spin-Echo T1 and T2
T1 Weighting
- Relatively short TR and TE
- Longitudinal relaxation contrast
- Simple fluid usually relatively dark
T2 Weighting
- Relatively long TR and TE
- Transverse relaxation contrast
- Simple fluid usually relatively bright
Sequence modifications can change signal appearance
Contrast & Emergency Picker
- Severe symptoms during contrast injection→Stop; summon response; assess ABC(Follow trained emergency protocol)
- Extravasation suspected→Stop injection; obtain clinical examination(Assess perfusion, sensation and movement)
- Severe/progressive extravasation symptoms→Obtain urgent surgical assessment(Do not use volume alone)
- IV contrast; no AKI; eGFR≥30→ACR: metformin need not stop(Local policy/label may differ)
- AKI/eGFR<30 or renal-embolic arterial study→Hold metformin; reassess after 48h(Authorized restart decision)
- Potential penetrating orbital ferromagnetic injury→Radiograph or review suitable prior CT(Metalworking alone is not indication)
CT & MRI Physics
- Helical Pitch
- Travel/rotation ÷ nominal beam width
- Pitch-Dose Relationship
- Inverse only with other settings fixed
- Water CT Number
- Approximately 0 HU
- Air CT Number
- Approximately −1000 HU
- CTDIvol
- Standardized phantom-based scanner-output index
- DLP Example
- 10mGy × 30cm = 300mGy·cm
- Proton Frequency
- 42.58 MHz/T × field strength
- 1.5T / 3T Protons
- Approximately 63.87 / 127.74 MHz
- MR Zone III
- Controlled access under Level-2 MR supervision
- ACR 2026 B₀ Hazard Area
- Within 9-gauss line; mapped spatially
- Orbital Trauma Concern
- Evaluate suspected penetrating ferromagnetic foreign body
Modality Physics Picker
- GBCA needed; CKD4/5→Use group II; avoid group I(Supervising clinician assesses benefit and risk)
- Bolus specified in therapy plan→Verify material, position and planned use(No independent treatment alteration)
- C-arm geometry can be optimized→Under-table tube; close receptor where feasible(Use shielding and appropriate exposure settings)
- 5Gy reference air kerma reached→Activate local follow-up process(Not measured peak skin dose)
- Tc-99m generator eluate prepared→Check radionuclidic and chemical purity(Use product limits and administration time)
Ultrasound, Nuclear Med & Therapy
- Ultrasound Assumed Speed
- 1540 m/s in soft tissue
- Ultrasound Output
- ALARA; indication-specific mode and duration
- Tc-99m Photon
- Approximately 140 keV
- Tc-99m Half-Life
- Approximately six hours
- TECHNELITE Mo-99 Limit
- ≤0.15 µCi/mCi Tc-99m at administration
- TECHNELITE Aluminum Limit
- ≤10 µg/mL before administration
- PET Annihilation
- Approximately 511keV paired photons
- 20% Window at 140keV
- 126–154keV: ±10% about centre
- Therapy Fractionation
- Repair, redistribution, reoxygenation, repopulation
- Tumor Repopulation
- Can oppose treatment control
- Bolus
- Use only as specified in plan
- Fluoroscopy Follow-Up Triggers
- 3Gy skin; 5Gy reference air kerma
Contrast, Renal Labs & Extravasation
- Metformin: IV, No AKI, eGFR≥30
- ACR: no routine interruption
- Metformin: AKI or eGFR<30
- Withhold; 48h; reassess before restarting
- Arterial Renal Embolic Risk
- ACR metformin withholding also applies
- Gadolinium: CKD4/5
- Avoid group I; use group II
- Known or Suspected AKI
- Group II preferred when GBCA needed
- Extravasation
- Stop injection; obtain clinical assessment
- Initial Limb Care
- Elevate; initially apply cold compresses
- Surgical Referral
- Severe/progressive symptoms; not volume alone
- Routine Extravasation Aspiration
- Not recommended by ACR
- Contrast Warming
- Not routinely supported for lower-viscosity agents
Common Traps
Dose Metric
Reference air kerma ≠ Peak skin absorbed dose
Rating Versus Raw Count
Official weighted rating ≠ Unvalidated number-correct conversion
Grid Specification
Grid geometric ratio ≠ Exposure multiplication factor
Detector Versus Patient
Detector exposure index ≠ Patient organ absorbed dose
Renal Contrast Groups
Group I gadolinium agents ≠ Group II gadolinium agents
MR Safety Geometry
Mapped magnetic-field contour ≠ Scanner-room physical wall
Warming Evidence
Lower-viscosity contrast agents ≠ Higher-viscosity contrast agents
Film and Digital Appearance
Film optical density ≠ Processed digital display brightness
Last Minute
- 1.500 items; five equally weighted subjects
- 2.Five sessions ×150min =750min
- 3.Pass average ≥75%; subjects ≥60%
- 4.Board has five specified professionals
- 5.Current PNRI lens: 20mSv five-year average
- 6.PNRI excludes DOH-FDA X-ray sources
- 7.Formula assumptions precede numerical substitution
- 8.Focused grids require correct geometry
- 9.Do not force injured joint movement
- 10.Metformin decision includes AKI and route
- 11.Gadolinium decision includes agent group
- 12.Extravasation referral follows clinical severity
- 13.MR safety includes implants and fields
- 14.Mammography phantom limit is not patient-limit
- 15.Follow-up trigger is not confirmed injury
Explore More Philippines PRC Health Exams
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
More From This Family
Videos and articles for deeper review.