Accessible Restrooms, Lavatories and Tactile Signs

Key Takeaways

  • Distinguish new from existing construction.

  • Turning space and fixture clear floor space are different.

  • Check a forward approach and knee clearance.

  • Measure grab-bar height to the gripping surface.

  • Measure tactile signs at character baselines.

Last updated: November 2026

Verify the edition and building condition

ICC A117.1-2017 distinguishes new and existing buildings and facilities for several dimensions. A circular turning space has a 67-inch minimum diameter in new construction and 60 inches in existing buildings and facilities under §304.3.1. The compliant T-shaped turning space is an alternative; check its geometry rather than substituting a square of the same diameter.

A lavatory generally needs clear floor space for a forward approach under §606.2. Section 305.3 specifies 30 by 52 inches in new buildings and facilities and 30 by 48 inches in existing ones. Check required knee and toe clearance and any allowed overlaps separately. A clear floor space at a fixture and an overall turning space are distinct measurements; satisfying one does not prove the other.

Inspect fixtures and signs after installation

For a typical adult accessible toilet compartment, check the water-closet position, side and rear grab bars, clearances and door swing with the actual accessories installed. The top gripping surface of a standard horizontal grab bar is generally 33 to 36 inches above the finished floor. Verify the appropriate location and configuration before applying that number.

For required tactile room identification, §§703.3.10–703.3.11 of A117.1-2017 address height and location. At a single door with available wall space, locate the sign alongside the latch side. Measure 48 to 60 inches using the lowest and highest raised-character baselines, respectively. Check alternate placements for double doors and missing wall space.

Test Your Knowledge

What is the circular turning-space minimum in new construction under ICC A117.1-2017?

A

67 inches

B

52 inches

C

60 inches

D

72 inches

Test Your Knowledge

What is the minimum new-building lavatory clear floor space under ICC A117.1-2017?

A

30 by 52 inches

B

30 by 48 inches

C

36 by 48 inches

D

36 by 60 inches

Test Your Knowledge

Where does a tactile sign typically go at a single door with wall space available?

A

On the wall at the latch side

B

On the hinge-side jamb

C

On the center of the door leaf

D

On the opposite corridor wall

Sections you finish are checked off in the contents.