Construction Type and Allowable Building Size

Key Takeaways

  • Table 601 gives ratings by element.

  • Section 602 sets material rules.

  • Check fire separation distance independently.

  • Use 504.3 for height and 504.4 for stories.

  • Use Table 506.2 for area factors.

Last updated: November 2026

Establish the construction type

Read §602 for the materials the construction type permits and Table 601 for the required ratings of particular elements. Types I and II generally use noncombustible elements subject to permitted exceptions. Type III generally uses noncombustible exterior walls, with a fire-retardant-treated wood allowance within specified exterior wall assemblies, and permits approved interior materials. Type IV covers several mass timber types; Type V allows materials permitted by the code.

A zero-hour entry for a primary frame does not settle every rating. Check Chapter 7 for exterior wall exposure, shafts, and opening protection. For an exterior bearing wall, consider both Table 601 and the fire-separation-distance requirements.

Check three different limits

  • Table 504.3: height in feet.
  • Table 504.4: allowable stories above grade plane.
  • Table 506.2: allowable area factors for the actual occupancy, construction type and sprinkler designation.

Example: the 2024 Table 504.3 shows 40 feet for a nonsprinklered Group B, Type V-B building and 60 feet in the applicable sprinklered row. A 43-foot nonsprinklered office fails the base height check even if its floor area is below the area limit. Conversely, satisfying the height row does not authorize another story or greater area. Read special allowances and table footnotes before making a final determination.

At an inspection, compare the approved building section, specified wall and floor assemblies and installed materials. A substitution that preserves nominal thickness can still change the tested assembly or allowed material. Require the approved design basis before accepting it.

Test Your Knowledge

Which table gives the allowable number of stories above grade plane?

A

Table 504.4

B

Table 504.3

C

Table 506.2

D

Table 601

Test Your Knowledge

What is the 2024 base height limit for a nonsprinklered Type V-B Group B building?

A

40 feet

B

50 feet

C

60 feet

D

65 feet

Test Your Knowledge

What Chapter 7 table adds an exterior-wall rating check based on fire separation distance?

A

Table 705.5

B

Table 706.4

C

Table 716.1(2)

D

Table 717.3.2.1

Sections you finish are checked off in the contents.