Stairs, Corridors and Egress Doors

Key Takeaways

  • Calculate width from capacity and check the minimum.

  • Corridor width and rating are separate.

  • Measure door opening with the leaf at 90 degrees.

  • The usual stair geometry is 7-inch riser and 11-inch tread.

  • Test operation and hardware after installation.

Last updated: November 2026

Check capacity and geometry

Calculate required capacity under §1005 before checking minimum widths. Table 1020.3 generally calls for a 44-inch corridor, with a 36-inch row for occupant loads below 50 and wider values for certain uses. This is separate from corridor fire resistance in Table 1020.2. For example, the nonsprinklered Group B row serving over 30 requires a one-hour corridor unless an exception applies.

A typical egress stair uses a 7-inch maximum riser and 11-inch minimum rectangular tread under §1011.5.2. Check uniformity, headroom, handrails, landings and guards in their own provisions. At a standard swinging door, measure clear opening between the door face and stop with the leaf at 90 degrees. A nominal 36-inch leaf is not itself proof of the usual 32-inch clear opening.

Test the door as installed

Under 2024 §1010.2.8, swinging doors serving Group H, or Group A or E rooms or spaces with loads of at least 50, generally may not have a latch or lock other than panic or fire exit hardware. Confirm that a rated door uses hardware appropriate to the rating and that the door closes and latches as required.

Inspect both opening force and unlatching. Section 1010.1.3 generally limits a manually operated nonrated interior swinging egress door to 5 pounds to open; different criteria apply to fire-rated and other doors. Check the required swing direction and threshold. A door can be wide enough yet fail because a lock, closer or landing prevents proper use.

Test Your Knowledge

Where does the IBC list minimum corridor width?

A

Table 1020.3

B

Table 1020.2

C

Table 1017.2

D

Table 1004.5

Test Your Knowledge

How should a swinging egress door’s clear width generally be measured?

A

Between door face and stop at 90 degrees

B

Between the rough opening jambs

C

Across the nominal leaf width

D

Between the hinges and handle at 45 degrees

Test Your Knowledge

A rated swinging door serves a 65-person Group E room. What hardware is generally needed if it latches?

A

Listed fire exit hardware

B

A residential passage latch

C

An ordinary deadbolt

D

Unlisted panic hardware

Sections you finish are checked off in the contents.