4.2 The pH Scale, Acid–Base Balance & the Skin’s Acid Mantle
Key Takeaways
Aqueous pH is the negative base-ten logarithm of hydrogen-ion activity. Each one-unit rise reduces the activity to one-tenth.
Pure water is near pH 7 at 25°C. The neutral pH of water depends on temperature.
A reading for a tested working mixture or dilution describes that preparation. An aqueous pH strip on pure oil is not a valid oil pH measurement.
The acid mantle describes the slightly acidic skin surface. A single pH value is not a target for every skin site, hair fiber or salon formula.
pH can affect hair swelling and charge. Check the formula and method before predicting how it will affect hair or skin.
4.2 The pH Scale, Acid–Base Balance & the Skin’s Acid Mantle
A pH value tells you something about the chemical environment a product will create. It does not tell you which ingredients are present, how long the product should remain on the hair, or whether the client is eligible for the service.
Meaning of the Scale
An ion has a net electric charge. In water, one water molecule can transfer a proton to another. This produces hydronium and hydroxide:
The symbol is the usual shorthand for the hydrated proton in the definition of pH:
Activity is the effective amount of an ion for chemical equilibrium. It is related to concentration, but interactions in solution matter. At 25°C, pure water is near pH 7, with equal amounts of hydronium and hydroxide. Near that temperature, aqueous samples with a lower pH than the neutral value are acidic and those with a higher pH are basic or alkaline. The neutral pH changes with temperature. The familiar 0–14 teaching scale covers many aqueous examples, but its endpoints are not universal limits. IUPAC pH definition and IAPWS water ionization standard
Make a Logarithmic Comparison
Subtract the lower pH from the higher pH. Use ten raised to that difference. The result tells you how many times greater the hydrogen-ion activity is in the lower-pH sample.
| Lower pH | Higher pH | Difference | Hydrogen-ion activity in the lower-pH sample |
|---|---|---|---|
| 7 | 8 | 1 | times as high |
| 7 | 9 | 2 | , or 100 times as high |
| 5 | 8 | 3 | , or 1,000 times as high |
| 5 | 13 | 8 | , or 100 million times as high |
Worked comparison. A liquid sample measures pH 7 and a working wave lotion measures pH 9 under comparable conditions. The pH 7 sample has 100 times the hydrogen-ion activity of the pH 9 sample. Conversely, the pH 9 sample has one-hundredth the activity. This calculation does not give the amount of acid required to neutralize the lotion or the chance of injury. An acid–base buffer resists a pH change when a small amount of acid or base is added. Two formulas can have the same initial pH but respond differently because their ingredients and buffer capacities differ.
Check What Was Measured
An aqueous strip or meter is meant for a suitable sample. Do not dip an aqueous strip in pure jojoba oil and record an apparent color as a salon pH value. Specialized nonaqueous methods exist. They require a measurement procedure and standards appropriate to the medium. When a safety data sheet describes the pH of a diluted powder or a prepared mixture, use that value only for the stated preparation. A dry lightener and a lotion made from it do not share an automatically assigned pH. IUPAC guidance on nonaqueous measurements
Skin Surface Acidity and Hair Response
The skin’s acid mantle refers to its slightly acidic surface. It contributes to the conditions in which resident organisms live and supports barrier function. Surface pH varies with location, person, measurement and recent cleansing. A study of 330 people reported a mean inner forearm measurement near pH 4.9 after a day without showering or applying cosmetics. That measurement does not specify one pH for scalp skin or for the hair shaft. Human skin surface pH study
For hair, pH can change the charge on protein groups, their interactions, and the fiber’s water uptake and swelling. In one controlled experiment with bleach-damaged hair, fibers equilibrated at pH 10 had a larger diameter than those equilibrated at pH 5. The results depended on the tested conditions. A label describing a product as acidic or acid-balanced does not promise a permanently sealed cuticle, fixed color retention or a particular clinical effect on the scalp. Controlled hair fiber experiment
Use pH With the Product Directions
| Salon example | How to use the information |
|---|---|
| Shampoo or conditioner | Confirm the intended use and follow the directions. A pH description alone does not establish suitability for injured skin or chemically compromised hair. |
| Hydroxide relaxer and finishing shampoo | Lye and no-lye formulas can both be strongly alkaline. Use the selected kit. Rinse out the relaxer before the specified post-relaxer step. An indicator is interpreted as the manufacturer directs. |
| Permanent wave or thio relaxer | The reducing agent and subsequent oxidation are different steps. Do not use the pH of one component to choose the neutralizer, heating or timing. |
| Oxidative hair color and lightener | Check the directions for the working mixture and application site. Formula and prior hair history affect suitability. |
Measured pH of lye and no-lye relaxers, Zotos wave chart and Design Essentials finishing directions
Two aqueous samples measure pH 7 and pH 9 under comparable conditions. Which comparison is correct?
The pH 9 sample has twice the hydrogen-ion activity.
The pH 7 sample has 100 times the hydrogen-ion activity of the pH 9 sample.
The samples have equal hydrogen-ion activity.
The pH 7 sample has 1,000 times the hydrogen-ion activity of the pH 9 sample.
A stylist dips a standard aqueous pH strip into pure jojoba oil. How should the result be interpreted?
The strip establishes that the oil is neutral at pH 7.
The strip gives the same result as measuring a later water-based emulsion.
This is not a valid use of an aqueous pH strip. A measurement needs a method appropriate to the sample.
If the oil is clear, the strip can establish it is acidic.
A label describes an after-color rinse as acid-balanced. What is justified before using it?
Follow the directions for this formula. A pH label alone does not guarantee color retention or a particular scalp response.
Treat it as approved for every abraded or irritated scalp.
Use it as the oxidizing neutralizer for any thio wave.
Assume its pH is the exact natural value for every hair fiber and skin site.
Sections you finish are checked off in the contents.