2.3 Patient Education, IV Therapy and Medication Checks
Key Takeaways
Use teach-back to check your explanation of preparation or recovery instructions.
Match the IV access site and device to the fluid or medication. Trace the actual connection before use or transfer.
Confirm the ordered route, concentration, compatibility and rate against the label and approved procedure.
Convert minutes to hours before entering an hourly pump rate. Check both total volume and rate.
Escalate new swelling, pain, unexpected resistance, discoloration or pump alarms and identify what has been infused.
2.3 Patient Education, IV Therapy and Medication Checks
Unfamiliar equipment and difficult terminology can interfere with a patient's understanding. Before an elective study, use plain language to explain the next steps, likely sensations and the way the patient can ask for help. Ask which language and communication support the patient needs and arrange the facility's interpreter services as appropriate. Confirm the procedural instructions the authorized team gave and bring questions about the decision or its risks back to that team. The formal consent discussion remains a separate responsibility.
Use teach-back to check your own explanation. For example, after reviewing the prescribed access-site instructions, ask the patient to explain whom they would contact if the site starts bleeding at home. A simple yes to “Do you understand?” leaves the team unsure what the patient heard. If the patient cannot explain the next step, explain again using different words and ask again. Use the approved written instructions and confirm who will help after discharge if the plan calls for a caregiver.
Select and verify venous access
An IV line may be needed for fluids, sedation, medication or emergency access. Match the device to the ordered treatment. A short peripheral catheter commonly enters a hand or forearm vein. It does not reach a central vein, and suitability depends on the required use. A central catheter may support other therapies but requires its own access and maintenance checks. An existing line needs confirmation of the specific lumen, condition and intended use before it is connected to new equipment. For high-pressure imaging administration, also verify the entire path and exact device labeling as described in section 11.1.
For peripheral venipuncture, review site restrictions and choose an appropriate patent vein under the facility protocol. Prepare the skin with approved antisepsis, respect the contact or drying requirements, and use aseptic technique. Once the line is established, inspect and secure the site and check patency before administration according to policy. A site immediately beside an infected, painful or compromised area or an arm reserved for dialysis access deserves clarification before placement. An active fistula or graft is a specialized access with separate rules.
Match the preparation to the order
| Check | What can go wrong |
|---|---|
| Patient, indication and route | An IV bolus, an ongoing infusion and an arterial administration are different orders. Verify that the formulation and site match the intended route. |
| Drug, concentration and units | Two labeled heparin preparations can serve different purposes. A vial marked 1,000 units/mL and “not for lock flush” cannot substitute for a catheter-lock product. |
| IV solution and compatibility | A clear solution can contain an incompatible additive. Check compatibility and stability before combining medicines or sharing a lumen. The label for 0.9% sodium chloride does not make it a universal diluent. |
| Timing and adverse effect | A sedative can worsen ventilation. An anticoagulant can increase bleeding risk. Review the indication, relevant contraindications, current medications and required monitoring with the authorized clinician. |
For a concentration check, 0.40 mL of a solution labeled 1,000 units/mL contains 400 units. Compare the calculated amount against the verified order and product. A concentration on a vial does not prescribe the amount to administer.
Use a manufacturer-prepared or pharmacy-prepared ready-to-administer product when available. Any reconstitution or dilution must follow approved instructions for the exact product using sterile supplies. Label prepared syringes and IV lines according to policy. A prefilled flush syringe is meant for its designated use. Do not use one as a general mixing container. Single-dose vials, syringes and infusion containers are for one patient under safe injection practice. If a package is leaking, the fluid appears discolored, or the line's intended contents cannot be confirmed, stop and resolve the uncertainty before use.
Delivery and monitoring
For an ordered volume and duration, divide milliliters by hours to get the pump rate. If 120 mL is ordered over 45 minutes, 45 minutes is 0.75 hours and mL/h. Giving the same volume over 90 minutes yields 80 mL/h. A gravity set instead uses the tubing's labeled drop factor. With a 20-drop/mL set and a prescribed 120 mL over 45 minutes, the calculation is drops per minute. Use the specified delivery method and verify the amount to be infused as well as the rate. These infusion rates use different units from most contrast injector settings.
Before moving the patient, trace active tubing from container or pump to its entry port. Confirm the correct line connections, battery or power plan, and which clinician is monitoring each infusion. Allow enough slack for safe table movement and verify what is actively infusing after the transfer. A pump's running display cannot establish that the medication is reaching the vein. For example, swelling or pain at the site with slowing flow suggests potential infiltration or extravasation. Stop the suspected infusion, notify the responsible clinician and follow the agent-specific pathway before flushing or removing access. An oncology vesicant can require different steps from iodinated contrast. Warmth, tenderness, redness or a palpable cord can suggest phlebitis, for which a peripheral catheter needs evaluation and removal under protocol. A kinked extension can trigger an occlusion alarm, and an unexplained alarm or a suspected malfunction needs investigation rather than simply restarting the pump.
In the handoff, report the fluid or drug, verified route and rate, volume delivered if known, what changed and the current appearance of the site. That information lets the next clinician continue the plan or investigate a problem without guessing.
A patient nods after hearing instructions about what to do if an access site starts bleeding at home. Which step checks whether the explanation was clear?
Ask the patient to repeat in their own words what to do and whom to call.
Treat the signed consent form as proof that the patient understands the instructions.
Repeat the instructions only if the patient says they have a question.
Ask the patient to repeat the manufacturer name of the closure device.
An approved infusion order specifies 120 mL over 45 minutes using a pump. Which conversion gives the intended hourly rate?
120 mL/h because the volume is 120 mL.
90 mL/h because 45 minutes is three quarters of an hour.
160 mL/h because 120 mL divided by 0.75 hours is 160 mL/h.
2.67 mL/h because 120 divided by 45 is about 2.67.
During a medication infusion, the access site becomes painful and swollen even though the pump shows that it is running. What is the next appropriate response?
Raise the rate to confirm the catheter is patent.
Place a warm compress immediately regardless of what the line contains.
Flush the line forcefully to check for an obstruction.
Stop the suspected infusion, assess and escalate, and identify the medication to follow its extravasation pathway.