17.1 EVAR & TEVAR Planning, Devices & Deployment

Key Takeaways

  • Apply the aneurysm recommendations to the correct aortic segment, patient and symptoms. An idealized wall model illustrates tension and stress.

  • Measure the seals and access with the named graft’s imaging conventions and instructions. Match the deployed parts and labeled component overlap.

  • Protect pelvic and other branch supply when feasible. Distinguish attachment leak from retrograde branch filling.

  • Confirm true contralateral gate entry before releasing a modular limb, and document branches, graft patency and sac filling on completion imaging.

  • Review the left subclavian and wider collateral plan before TEVAR. Escalate new neurological findings promptly and prepare for the ordered rescue strategy.

Last updated: November 2026

17.1 EVAR & TEVAR Planning, Devices & Deployment

Clinical Core: Endovascular aneurysm repair (EVAR) excludes an abdominal aortic aneurysm from arterial pressure using a stent-graft. Thoracic endovascular aortic repair (TEVAR) treats selected thoracic aortic disease. The team decides when repair is appropriate, then separately verifies anatomy, equipment and the plan to preserve vital branches.

Aneurysm and wall mechanics

An abdominal aortic aneurysm (AAA) is generally defined at an abdominal aortic diameter of at least 3.0 cm. Many AAAs are infrarenal. The aortic segment, morphology, comparable measurements over time and symptoms affect decisions. In its recommendations for unruptured AAA, the 2022 U.S. ACC/AHA guideline recommends repair at a maximum diameter of at least 5.5 cm in men or 5.0 cm in women and when symptoms are attributable to the aneurysm. Growth of at least 0.5 cm in six months can justify considering repair. Saccular morphology can also influence the decision. New pain with suspected rupture requires immediate assessment.

For intact descending thoracic aortic aneurysm (TAA), ACC/AHA recommends repair at a diameter of at least 5.5 cm. Symptoms, rapid growth, saccular morphology, genetic disease and other risk factors can change the threshold or repair strategy. Other TEVAR indications, such as complicated type B dissection and selected traumatic aortic injury, have separate criteria.

Worked model of circumferential load

For a thin-walled cylindrical approximation, pressure across the wall PP acts over a projected width of 2r2r. Two cut wall edges balance the force. Circumferential tension per unit axial length is T=PrT=P r. Dividing by wall thickness hh gives the approximate average circumferential stress.

σθ=Prh\sigma_{\theta}=\frac{P r}{h}

At the same transmural pressure and wall thickness, increasing the radius from 2 to 3 cm raises modeled circumferential stress by 50%. An actual aorta has changing thickness, asymmetric geometry, pulsatile pressure and variable tissue strength. The model illustrates the direction of the change. Clinical rupture assessment uses the patient's imaging and disease context.

Imaging and device selection

Preprocedural computed tomography angiography (CTA) and centerline reformats help the team measure lengths along the proposed delivery path and diameters perpendicular to the axis. Use the named device’s measurement conventions. Report available seal length, neck shape and angulation, thrombus and calcium, branch origins, and iliac or femoral access caliber and tortuosity. The device’s actual delivery profile and access anatomy determine whether access is feasible.

CheckMechanism or consequence
Proximal seal and fixationThe fabric needs contact with the planned sealing segment. Fixation can use radial support or anchors depending on the design. A bare fixation segment and a fabric seal have different relationships to branch vessels.
Distal seal and pelvic flowA common iliac seal can preserve the internal iliac origin. Extension into the external iliac artery can require a planned branch strategy. Assess whether preservation or embolization is appropriate.
Component size and overlapThe nominal graft diameter and target vessel diameter are read from the specific sizing table. Match the expected overlap and marker locations for the exact components.
Access and closureConsider access from one or both sides, percutaneous versus surgical access, and alternative routes when delivery is limited. Follow actual closure labeling and the operator’s plan.

The FDA's 2024 U.S. supplement for the GORE EXCLUDER Conformable AAA Endoprosthesis specifies an infrarenal neck diameter of 16–32 mm, minimum neck length 10 mm, proximal angulation 90° or less, iliac treatment diameter 8–25 mm, and distal iliac seal length at least 10 mm, with adequate access. These are factors in assessing that model. Other designs and regional label versions can have different criteria. A patient may meet an aneurysm indication for repair and still need a different approach.

When iliac disease threatens the distal seal, the team weighs an iliac branch device, branch occlusion, surgery or another plan. ACC/AHA recommends preserving flow to at least one hypogastric artery when anatomically feasible during repair of concomitant iliac aneurysm. Loss of pelvic inflow can cause buttock claudication or more serious ischemia. Retrograde sac filling from a branch is type II endoleak. A distal attachment leak is type Ib. Determine the source of flow before describing the leak.

Modular EVAR setup and deployment checks

A modular bifurcated graft usually includes a main body and an iliac limb that connects through a contralateral opening. Iliac extensions and aortic cuffs can be used with compatible systems. Endografts combine a metal scaffold with graft fabric, such as polyester or expanded polytetrafluoroethylene, depending on the device.

  1. Prepare access and imaging. Confirm the access strategy, closure equipment, anticoagulation and monitoring orders, and the labeled sheath, wire and device. Profile the renal and iliac landmarks with patient-specific projections.
  2. Confirm body position. Identify the markers for the graft fabric, branches and both iliac outlets. During deployment, verify the position relative to the intended seal and the lowest relevant renal artery.
  3. Verify the gate before limb release. An angled catheter and compatible wire can be used to enter the contralateral opening. Confirm the course within the graft using the device’s fluoroscopic and angiographic checks. Projected alignment can be misleading in a single view. In the named EXCLUDER Conformable system, aligning the contralateral limb marker with the long contralateral trunk marker gives approximately 3 cm of overlap. Apply the exact component instructions to other junctions.
  4. Review molding and completion. Use the specified balloon configuration only if selected, under the system instructions. Completion imaging assesses branch flow, graft position and patency, and residual sac filling. Report an observed leak and document its location. The surveillance plan remains important after a satisfactory completion image.

TEVAR and spinal perfusion

The arch zones describe the position relative to branches. In the commonly used Ishimaru convention, zone 0 is proximal to the brachiocephalic origin, zone 1 lies between the brachiocephalic and left common carotid origins, and zone 2 lies between the left common carotid and left subclavian origins. Zone 3 is the distal arch beyond the left subclavian artery and zone 4 is the proximal descending thoracic segment in the reporting convention. Confirm the actual landing landmarks.

For planned left subclavian coverage in descending TAA repair, ACC/AHA recommends revascularization before TEVAR to help prevent spinal cord injury and potentially reduce stroke and other ischemic complications. The strategy can involve a bypass or a suitable branch-preserving endovascular device. Urgency, vertebral flow, prior left internal mammary coronary bypass and left arm dialysis access affect the decision. Report a bird-beak appearance, a wedge-shaped gap at the inner arch curvature, because incomplete apposition is associated with endoleak.

Assess spinal risk and recognize new weakness

Long thoracic coverage, prior aortic repair, impaired pelvic or subclavian collateral supply and perioperative hypotension can increase the risk of spinal cord ischemia. The artery of Adamkiewicz supplies the anterior spinal arterial network. Primary imaging studies describe a frequent lower-thoracic or upper-lumbar origin on the left, with right-sided and other levels also observed. The total collateral supply and physiological conditions matter.

The spinal perfusion gradient can be approximated as mean arterial pressure minus the greater of cerebrospinal fluid (CSF) pressure or central venous pressure when referenced comparably. For example, 90 mmHg mean arterial pressure, 12 mmHg CSF pressure and 15 mmHg venous pressure yield an estimated gradient of 75 mmHg. This illustrates the effect of systemic pressure and drainage conditions. It is not a target for an individual case.

U.S. SVS guidance supports prophylactic CSF drainage in selected high-risk TEVAR cases. The 2026 ESVS guideline permits a rescue strategy in preference to routine prophylactic drains for extensive endovascular repair. The team applies a patient-specific plan for pressure, collateral preservation, neurological examinations and drainage, including the risks of an invasive drain. New leg weakness or sensory change requires immediate communication and urgent evaluation for spinal cord ischemia. Support the team’s perfusion and rescue plan, which may include hemodynamic optimization and CSF drainage.

Loading diagram...
Endograft Planning and Deployment Checks
Test Your Knowledge

An infrarenal AAA is being evaluated for the U.S. GORE EXCLUDER Conformable device under FDA supplement P200030/S014. Iliac anatomy and access meet the instructions. Which set of proximal neck measurements is within the labeled numerical criteria?

A

Length 12 mm, diameter 24 mm, proximal angle 75°.

B

Length 8 mm, diameter 24 mm, proximal angle 55°.

C

Length 18 mm, diameter 34 mm, proximal angle 58°.

D

Length 16 mm, diameter 26 mm, proximal angle 95°.

Test Your Knowledge

The wire projects over the contralateral gate marker on a single view during modular EVAR. What should happen before releasing the contralateral limb?

A

Release the limb based on the projected wire alignment alone.

B

Confirm the wire and catheter are inside the intended graft opening using the applicable device and imaging checks, then verify the prescribed component overlap.

C

Assume any wire that passes within the aneurysm sac entered the graft.

D

Confirm the distal iliac landing zone and use that finding as proof of proximal gate access.

Test Your Knowledge

After extensive descending TEVAR in a patient with prior abdominal aortic repair, new bilateral leg weakness develops. Which complication and response should the technologist prioritize?

A

Routine postprocedure fatigue. Repeat the exam at the next scheduled visit.

B

Isolated left arm ischemia. Focus only on the left wrist pulse.

C

Possible spinal cord ischemia. Notify the team immediately and support urgent assessment and the perfusion rescue plan.

D

A benign change expected whenever the thoracic insertion sheath is removed.