1. AV Blocks: First, Second, and Third Degree

Key Takeaways

  • First-degree AV delay has 1:1 conduction with PR intervals over 0.20 seconds.

  • Typical Mobitz I shows PR lengthening before a nonconducted P wave, then a shorter PR as the group restarts.

  • Mobitz II shows a nonconducted P wave without PR change before or after it at a steady atrial rate. A wide QRS may accompany it. Escalate promptly.

  • Complete AV block has no atrioventricular conduction. A junctional or ventricular escape may sustain independent ventricular activity.

  • Describe 2:1 conduction without assigning a Mobitz subtype from that ratio alone. Report it promptly and assess the patient.

Last updated: November 2026

An atrioventricular (AV) conduction disorder can delay transmission from the atria to the ventricles or prevent some or all atrial impulses from conducting. Measure the PR from the start of the P wave to the start of the QRS. A usual adult PR interval is 0.12–0.20 seconds, or three to five small squares at 25 mm/s. Compare P waves, QRS complexes and their timing before reporting the pattern.

First-Degree AV Block: Every P Conducted, Every PR Long

First-degree AV block, more precisely first-degree AV delay, means the PR exceeds 0.20 seconds and atrial impulses still conduct 1:1. The delay is often nodal. The underlying rhythm and QRS width can vary independently. Increased vagal tone or rate-slowing drugs can contribute. Report the PR and clinical context under facility protocol. Marked prolongation or symptoms warrant closer assessment.

Second-Degree AV Block, Mobitz Type I (Wenckebach)

Second-degree AV block means some atrial impulses conduct and some fail to conduct. In typical Mobitz I (Wenckebach):

  1. The PR lengthens within a group, for example 0.16, 0.24, then 0.28 seconds.
  2. A P wave arrives without a corresponding QRS.
  3. The next conducted beat has a shorter PR, and the group may repeat.

A worked comparison uses a steady P–P interval of 0.80 seconds. The two within-group R–R intervals are 0.80 + 0.08 = 0.88 seconds and 0.80 + 0.04 = 0.84 seconds. With one blocked P and the PR returning from 0.28 to 0.16, the pause between QRS complexes is 2 × 0.80 − 0.12 = 1.48 seconds. This typical pattern illustrates why the R–R intervals can shorten as the PR lengthens. Look at the actual PR increments and P waves rather than relying on the pause alone.

Mobitz I often occurs at the AV node and may be well tolerated. A narrow QRS supports a nodal level without proving it. A new pattern or symptoms still warrant assessment and reporting under the local protocol.

Second-Degree AV Block, Mobitz Type II: The Dangerous Dropped Beat

Mobitz II shows a single nonconducted P wave with stable P–P spacing and unchanged PR intervals in the conducted beats on either side of the drop. For example, PR intervals of 0.16 seconds before and after a missed QRS support this pattern if the P wave arrives on time and the strip also shows successive conducted beats. Sinus slowing around the drop or a premature P hidden in T can mimic other block patterns. A wide QRS often accompanies Mobitz II, but a narrow QRS does not exclude it.

Mobitz II reflects disease within or below the His bundle and can progress to high-grade or complete block. Report a suspected pattern directly and promptly. A patient with hypotension, altered mental status, chest discomfort or other signs of low perfusion requires immediate help. High-grade AV block has at least two successive nonconducted P waves at a physiologic atrial rate with some other atrial impulses still conducting.

Third-Degree (Complete) AV Block

Third-degree AV block means no atrial impulses conduct to the ventricles. When sinus P waves and a regular escape are visible, the P waves and QRS complexes often maintain separate cadences, with a slower ventricular rate and changing apparent PR intervals. Follow the P waves through QRS complexes, ST segments and T waves. Atrial and ventricular independence is a clue; AV dissociation can have causes other than complete block.

A junctional escape often runs near 40–60 bpm and may be narrow. A ventricular escape often runs near 20–40 bpm and is usually wide. Report suspected complete block promptly, whatever the escape morphology. Assess the patient and activate emergency help for signs of compromise.

The 2:1 Caution: When You Cannot Tell Which Mobitz It Is

When every other sinus P wave conducts, describe 2:1 AV conduction. The ratio supplies no consecutive conducted beats within the pattern, so it cannot establish Mobitz I versus Mobitz II. Other segments with a different ratio, or clinical evaluation, may clarify the level. QRS width alone is insufficient. State the atrial and ventricular rates, ratio, symptoms and timing, and escalate a new finding promptly.

Comparing AV Conduction Patterns

PatternPR and conductionImportant reporting detail
First-degree AV delayPR >0.20 s, 1:1 conductionRecord the measured interval and symptoms
Mobitz ITypical PR lengthening and a nonconducted P, then a shorter PRDescribe the grouped beats and the patient’s condition
Mobitz IIOn-time nonconducted P with constant PR before and afterEscalate promptly; progression is possible
2:1 AV conductionEvery other P conductsState the ratio and both rates without assigning a subtype
High-grade AV blockAt least two consecutive P waves fail to conduct, with some conduction elsewhereReport promptly and assess perfusion
Complete AV blockNo evidence of atrial impulses conductingReport the escape rate, QRS width and perfusion promptly

What the Technician Does

  • Check the patient first. Escalate symptomatic bradycardia or signs of poor perfusion immediately. If the patient becomes unresponsive, follow the adult BLS assessment.
  • State the PR behavior, atrial and ventricular rates, P-to-QRS ratio, escape morphology and times. Use a second lead or a repeat when appropriate to distinguish real atrial activity from artifact without delaying escalation.
  • Compare each candidate blocked P with the expected P–P cycle. A premature P concealed in a T wave can mimic a dropped beat.

Compare two strips at an atrial rate of 68 bpm. Both show one on-time P wave without a QRS after several conducted beats. In the first, PR measurements are 0.16 seconds on both sides of the drop. This supports Mobitz II. In the second, PR lengths increase from 0.18 to 0.26 to 0.30 seconds before the drop and restart at 0.18. This supports Mobitz I. Report both with the strip and the patient’s condition; the Mobitz II pattern has particular risk of progression.

Test Your Knowledge

P waves are regular. The PR increases from 0.16 to 0.24 to 0.28 seconds, an on-time P wave has no following QRS, and the next PR restarts at 0.16 seconds. Which pattern fits?

A

First-degree AV block, because every P wave eventually conducts

B

Second-degree AV block, Mobitz type I (Wenckebach)

C

Second-degree AV block, Mobitz type II

D

Third-degree AV block with a junctional escape rhythm

Test Your Knowledge

Which statement best explains why Mobitz type II is treated as more dangerous than Wenckebach?

A

It produces a slower atrial rate than Wenckebach does

B

Its dropped beats are always preceded by progressively longer PR intervals

C

Its constant-PR sudden drops can progress without warning to complete heart block or long pauses

D

It occurs only in patients taking rate-slowing medications

Test Your Knowledge

In a tracing with complete AV block, which escape location is most consistent with a wide QRS at 28 bpm?

A

A ventricular escape pacemaker

B

A junctional escape pacemaker

C

Normal sinus conduction with a wide QRS

D

First-degree AV block

Test Your Knowledge

A strip shows 2:1 conduction — every other P wave blocked — with a narrow QRS. What is the correct technician understanding?

A

A narrow QRS proves Wenckebach, so report it routinely

B

The ratio proves Mobitz II

C

This is first-degree delay because some beats conduct

D

Describe 2:1 AV conduction, assess the patient and report promptly. The ratio alone cannot establish a Mobitz subtype.

Sections you finish are checked off in the contents.