4. Recognizing Critical Findings (STEMI, Lethal Arrhythmias)
Key Takeaways
Ventricular fibrillation, pulseless ventricular tachycardia, and asystole are cardiac arrest rhythms. Activate emergency response immediately and provide BLS as indicated within training.
For a flat tracing, assess the patient first. In suspected arrest, begin the indicated BLS response without waiting to inspect the leads or confirm asystole.
Report new ST elevation in contiguous leads, an acute-MI machine alert, or ischemic symptoms with a conduction abnormality promptly. The clinician applies the lead-specific criteria and interprets the findings.
The technician reports to the assigned nurse (per protocol) and the provider, directly and at once, covering rhythm, rate, symptoms, vital signs, and the machine alert — in SBAR structure.
Report critical findings directly and promptly, follow the emergency protocol for instability, and document the response afterward.
The Findings That Cannot Wait
The recognition tasks in Domain 5 culminate here: lethal rhythms and STEMI-level findings that require the technician to stop, escalate immediately, and document. The operating rule is simple: any rhythm or waveform finding that could kill within minutes, or that signals an acute coronary occlusion, is reported the moment it is seen — directly, to a person, not into a queue.
The Lethal Rhythms
Ventricular fibrillation (VF). Chaotic, irregular waves of every shape and height; no identifiable P waves, QRS complexes, or T waves; and no effective mechanical contraction — no pulse. VF is a cardiac arrest rhythm: the patient collapses. Recognition is instant, and the response is the emergency response team with CPR and defibrillation by trained responders. The technician calls for help and follows facility protocol.
Pulseless ventricular tachycardia (VT). Ventricular tachycardia appears as a rapid, usually regular, wide-complex rhythm. Ventricular tachycardia can impair filling and cardiac output. Determine whether the patient has a definite pulse using the indicated response assessment. Any sustained VT — and any VT in an unresponsive, pulseless patient — is an emergency. If the patient is unresponsive and not breathing normally, activate emergency response and follow the adult BLS assessment within your training.
Asystole. A nearly flat trace without discernible ventricular electrical activity can represent asystole. A loose cable or detached electrodes can imitate it. Assess responsiveness first. For an unresponsive adult with absent or abnormal breathing, activate emergency response and follow BLS immediately; a trained responder checks breathing and pulse together within 10 seconds. If no pulse is definitely felt, start CPR and use the AED when available. If the patient is responsive, check the cable, electrodes, and display settings. In an arrest, the team can verify the signal alongside resuscitation.
Severe bradyarrhythmias. Rates in the 20s and 30s, long pauses (Section 3), or a slow wide-complex escape rhythm can fail to sustain perfusion. They are urgent findings with immediate notification, and the symptomatic patient is never left alone.
| Rhythm | Tracing appearance | Patient status | Technician action |
|---|---|---|---|
| Ventricular fibrillation | Chaotic irregular waves; no organized complexes | No pulse; cardiac arrest | Activate emergency response immediately |
| Pulseless VT | Rapid wide-complex rhythm | No pulse despite the tracing | Activate emergency response immediately |
| Asystole | Near-flat trace without discernible ventricular activity | Arrest when clinically confirmed | Treat suspected arrest promptly; verify the signal without delaying care |
| Severe bradycardia | Rate roughly under 40, long pauses, or slow wide escape | Often symptomatic | Immediate report; stay with the patient |
STEMI-Level Findings
ST-segment elevation. New elevation at the J point in contiguous leads can signal acute coronary occlusion. Outside leads V2–V3, the usual threshold is at least 1 mm in two contiguous leads when left ventricular hypertrophy or bundle branch block does not account for the pattern. V2–V3 have separate age- and sex-dependent thresholds. Report the leads, amount of elevation, any reciprocal changes, and symptoms. For orientation, II, III, and aVF view the inferior wall; V1–V4 view septal and anterior regions; I, aVL, V5, and V6 view lateral regions.
Left bundle branch block (LBBB) with ischemic symptoms. Report these symptoms and the tracing urgently. LBBB changes the baseline ST-T pattern, so the clinician assesses for concordant or disproportionate changes using the appropriate criteria and clinical context. The fact that LBBB is new is insufficient by itself to classify the tracing as a STEMI equivalent.
Machine acute-MI alerts. Many 12-lead units print interpretation banners such as ACUTE MI SUSPECTED. Relay the alert immediately along with the tracing and symptoms. Machine interpretation can miss ischemic changes or flag another pattern. Report the flag as machine-generated and include the observed tracing and symptoms.
Other urgent flags. Report suspected VT and a new high-grade or complete AV block promptly. Do not wait to see whether a possible VT run lasts 30 seconds. In high-grade AV block, two or more consecutive P waves fail to conduct while others still conduct. With complete block, atrial impulses fail to conduct and an escape may drive ventricular activity. For AF with a fast ventricular response, report the rate and symptoms and follow the urgent pathway for acute distress or signs of poor perfusion. A rate or waveform alone does not determine the patient’s status.
The Escalation Protocol
- WHO: the patient's assigned nurse first when protocol directs, and the physician or provider responsible for the patient, per the facility's critical-findings policy. Know the chain before you need it.
- HOW: directly and immediately — face to face or by phone — using the facility's SBAR structure: Situation, Background, Assessment, Recommendation. The guide's Domain 1 communication chapter covers SBAR and communication standards in full.
- WHAT: the rhythm and rate you measured; the specific waveform finding (ST elevation and in which leads, pause length, machine alert text); the patient's symptoms and vital signs; and the exact time of the finding.
Important
The sequence is recognize, report, record. Report first, then document — never let documentation delay the call.
The Do-Not-Do List
- Do not interpret the tracing to the patient or family — no reassuring them that it is nothing, and no frightening them with your conclusions.
- Do not administer treatment, medication, or oxygen on your own authority, even if you anticipate the order.
- Do not wait to batch critical findings with routine reporting, end-of-shift handoff, or the next scheduled rounding.
- Do not trust or dismiss the machine interpretation — escalate the pattern itself.
- Do not leave the tracing in the machine or walk away after uploading it; the report is complete only when a human being has acknowledged it.
Documenting the Alert
Every alert generates its own documentation: the time the finding was identified, exactly what was seen, to whom it was reported (name and role), the time of the report, the response received, and any repeat escalation. Section 6 covers the full documentation workflow, including the follow-up loop when nobody acknowledges your report.
The monitor tracing suddenly becomes a flat line. What is the technician's first action?
Declare asystole and start compressions based on the monitor alone
Increase the paper speed and recapture the tracing
Report asystole and leave to troubleshoot the monitor
Assess the patient immediately. If arrest is suspected, activate emergency response and follow adult BLS. Check equipment without delaying care.
Which description matches ventricular fibrillation?
A regular narrow-complex rhythm at 180 bpm with visible P waves
Chaotic, irregular waves of varying shape and height with no identifiable P waves, QRS complexes, or T waves, and no palpable pulse
A slow regular rhythm at 38 bpm with upright P waves
A flat, isoelectric tracing with no electrical activity
A 12-lead shows 3 mm of ST elevation in leads V2 through V4 in a diaphoretic patient with crushing chest pressure, and the machine prints an acute-MI alert. What is the correct action?
Notify the physician immediately and follow the facility STEMI escalation protocol, documenting the time of the finding and the report
Reposition the electrodes and retake the EKG before telling anyone
Explain to the patient that the machine may be wrong
Batch the finding with the next scheduled rounding report
Sections you finish are checked off in the contents.