3. Cardiac History and Medication Documentation
Key Takeaways
Document the presenting symptoms and relevant cardiac history - prior MI, angina, heart failure, hypertension, arrhythmias (especially atrial fibrillation), strokes, cardiac surgeries, and implanted devices - before the recording begins.
Record any pacemaker or implantable cardioverter-defibrillator (ICD). Some devices can pace, but visible pacing spikes depend on the device, its activity, and the recorder.
Record current drugs and relevant timing. Metoprolol can slow heart rate, some diuretics can lower potassium, and ACE inhibitors can lower blood pressure and raise potassium.
Documentation must be factual and contemporaneous - recorded at the time of collection, in objective language, in the patient's chart or electronic health record (EHR).
Collect information needed for the task and share it through authorized clinical channels with appropriate privacy safeguards.
Why History and Medications Matter to the Tracing
An EKG is never interpreted in a vacuum. The same tracing can be normal for one patient and alarming for another, depending on history, symptoms, and medications. That is why the Patient Care and Preparation blueprint includes documenting history, medications, and devices (2.5), recognizing common conditions (2.6), and recognizing the effects of common medication classes (2.7). The technician does not interpret the tracing and does not diagnose - but the technician is frequently the person who makes sure the history a physician needs is present in the chart when the interpretation happens. Acquiring, recognizing, and reporting is your scope; judging what the tracing means is not.
What to Document Before Testing
Collect a focused history before electrodes come out of the pack. Ask open-ended questions, listen, and record what the patient reports:
- Presenting symptoms - chest pain or pressure (and what provokes or relieves it), palpitations, shortness of breath, dizziness, syncope, swelling of the ankles.
- Prior cardiac events - previous myocardial infarction (MI), angina, or heart failure (HF).
- Hypertension - persistently elevated blood pressure.
- Arrhythmias - especially atrial fibrillation (AF), a common sustained arrhythmia. Ventricular response is usually irregularly irregular, with exceptions such as complete AV block or ventricular pacing.
- Implanted devices - pacemaker or implantable cardioverter-defibrillator (ICD).
- Neurologic history — stroke or transient ischemic attack (TIA). Record what the patient or chart identifies, and promptly escalate new focal neurologic symptoms.
- Cardiac surgeries and procedures - coronary artery bypass graft (CABG) surgery, stent placement or other coronary interventions, valve repair or replacement.
| Condition | Basic meaning | Why it matters to the technician |
|---|---|---|
| Hypertension | Chronically elevated blood pressure | Common reason for testing; baseline vitals matter |
| Myocardial infarction | Death of heart muscle due to ischemia | Prior injury may affect the baseline tracing. Report new symptoms promptly. |
| Myocardial ischemia | Oxygen supply to heart muscle is insufficient for demand | Report new chest pressure or relevant symptoms promptly. |
| Transient ischemic attack (TIA) | Transient focal neurologic symptoms due to ischemia without acute infarction | Document the history and promptly escalate new focal symptoms even if they resolve. |
| Atrial fibrillation | Chaotic atrial rhythm; irregular pulse | Explains an irregular rhythm so it is not mistaken for artifact |
| Heart failure | Syndrome in which a structural or functional heart problem impairs filling or ejection | The patient may have trouble lying flat. Adapt positioning as directed and note the position. |
| Valve disease | Damaged or replaced heart valve | May explain murmurs, prior surgeries, or anticoagulant use |
Implanted Devices: Pacemakers and ICDs
Record the device type when known and use verified information, such as the chart or device card. A pacemaker or a pacing-capable ICD may produce brief pacing spikes. Some devices lack the relevant pacing function, a pacing-capable device may not be pacing during the recording, and small pacing pulses may not be apparent on the tracing. Device history helps the clinician interpret what is present. A routine recording does not require adjusting a device or applying a magnet. Other procedures involving magnets or electrocautery require a separate plan from the clinical team.
Medications That Shape the Tracing
The medication list provides context for observed rate, conduction, and other findings:
| Medication class | Common examples | Relevance to the EKG encounter |
|---|---|---|
| Beta-blockers | Metoprolol, atenolol | Slow the heart rate - a resting rate of 55 may be the expected drug effect, not a new problem |
| Calcium channel blockers | Diltiazem, verapamil | Also slow the rate and affect conduction |
| Cardiac glycoside | Digoxin | Can slow ventricular response in atrial fibrillation. It has a separate role in selected patients with heart failure. |
| Loop and thiazide diuretics | Furosemide, hydrochlorothiazide | Can lower potassium. The clinician evaluates electrolyte results and the tracing together. |
| Angiotensin-converting enzyme (ACE) inhibitors | Lisinopril | Reduce angiotensin II formation and lower blood pressure. Potassium can rise. |
| Antiarrhythmics | Amiodarone and related drugs | Prescribed specifically to change rhythm and conduction |
| Anticoagulants / antiplatelets | Warfarin, apixaban, aspirin | Skin bruises and bleeds easily - prepare skin gently, expect easy marks |
The pattern to remember for the exam: beta-blockers lower the rate; diuretics shift potassium. A slow rate can occur with metoprolol. Document the rate, associated symptoms, and the medication so the clinician can evaluate other possible causes. The technician records the facts; the interpreter decides what they mean.
Where and How to Document
History and medications belong in the patient's chart or electronic health record (EHR) - the same record the tracing is attached to, not a loose note or your memory. Follow three documentation rules:
- Factual - objective observations and the patient's own words for symptoms ('crushing pressure under the sternum for one hour'), never your speculation or diagnosis.
- Contemporaneous - recorded at the time of collection, not reconstructed at the end of shift. Late entries are marked as such per policy.
- Attributed - your identification on each entry, with the date and time.
If a family member supplies history for a patient who cannot answer, record who provided it. If a name or last dose is uncertain, identify the source and record the uncertainty. Verify it through the facility’s medication-reconciliation process rather than guessing.
Important
Everything you gather is confidential health information. Collect what the assignment requires and use authorized channels, with reasonable safeguards for conversations in shared settings. Privacy is part of the documentation task, not a separate nicety.
Scenario: The Slow Rate
A pre-operative patient's resting rate reads 52 beats per minute, and the monitor technician flags it. The chart you documented lists metoprolol taken daily for hypertension and an ICD implanted two years ago. Record the rate, symptoms and vital signs, timing of any pacing spikes, and available medication and device details. Give the designated clinician the tracing and context. Clinical judgment determines whether the rate reflects medication effects, device behavior, or a new problem.
A patient's resting tracing shows a slow heart rate. The chart lists metoprolol. Why must the technician document this medication before testing?
Beta-blockers such as metoprolol slow the heart rate, so the medication entry lets the interpreter judge whether the slow rate is the expected drug effect or a new problem
Beta-blockers raise the heart rate, which explains why the tracing is fast
Metoprolol has no relationship to the tracing, so documenting it is optional
The medication must be held before any EKG can be performed
Why must the technician record an implanted pacemaker or ICD before performing an EKG?
The device requires a different skin-cleaning product
Turn the device off before recording
Record the device type for billing alone
Device history helps the clinician interpret any pacing activity and plan care for procedures that may interact with the device
Sections you finish are checked off in the contents.