12.4 Optical Instruments: Magnifiers, Microscopes, Telescopes, Spectrometer & Fibre Optics
Key Takeaways
Angular magnification compares the angle an image subtends at the eye with the angle the object subtends at the near point ; a simple magnifier gives with the image at the near point.
A compound microscope multiplies objective and eyepiece magnifications: , so both lenses should have short focal lengths.
An astronomical telescope in normal adjustment has and length , so the objective has a long focal length and the eyepiece a short one.
Resolving power improves with a larger aperture and shorter wavelength: the minimum resolvable angle is .
Optical fibres guide light by total internal reflection; the critical angle obeys , and graded-index fibres reduce the spreading of pulses compared with step-index multimode fibres.
Optical Instruments: Magnifiers, Microscopes, Telescopes, Spectrometer & Fibre Optics
Optical instruments use lenses and mirrors to make small or distant objects appear larger, or to analyse light. Questions on this topic are mostly formula-based and fast, provided the sign conventions and the meaning of "magnifying power" are clear.
1. Least Distance of Distinct Vision and Angular Magnification
The near point of a normal eye is about ; this is the least distance of distinct vision. How large an object looks depends on the angle it subtends at the eye, not on its actual size.
The magnifying power (angular magnification) of an instrument is
2. The Simple Microscope (Magnifying Glass)
A convex lens of focal length is held close to the eye with the object inside its focal length. It forms a virtual, erect, enlarged image.
- Image at the near point (maximum magnification):
- Image at infinity (relaxed eye):
Example: a lens with gives with the image at the near point. A shorter focal length (more powerful lens) gives larger magnification.
3. The Compound Microscope
Two converging lenses are used:
- The objective (short focal length ) forms a real, inverted, magnified image of an object placed just beyond its focal point.
- The eyepiece (short focal length ) acts as a simple magnifier for that image.
The total magnifying power is the product of the two stages. With the final image at the near point,
where is approximately the distance between the lenses. The final image is virtual and inverted relative to the object.
Example: , , : .
4. The Astronomical (Refracting) Telescope
The objective has a long focal length and forms a real, inverted image of a distant object at its focal plane. The eyepiece has a short focal length and magnifies that image.
In normal adjustment the final image is at infinity:
Example: and give and a tube length of 105 cm. The final image is inverted, which does not matter for viewing stars; a terrestrial telescope adds an erecting lens and becomes longer by of that lens.
| Instrument | Objective | Eyepiece | Magnifying power |
|---|---|---|---|
| Simple microscope | — | Single lens, short | |
| Compound microscope | Short | Short | |
| Astronomical telescope | Long | Short |
5. Resolving Power
Magnification is useless if two nearby points blur into one. By Rayleigh's criterion, two point sources are just resolved when the central maximum of one diffraction pattern falls on the first minimum of the other (see Section 12.3). For a circular aperture of diameter :
- A telescope with a larger objective resolves finer detail; this is a main reason large telescopes are built.
- An electron microscope achieves far higher resolution than an optical one because electron wavelengths (de Broglie) are much shorter than visible wavelengths.
6. The Spectrometer
A spectrometer measures refractive indices and wavelengths. Its three parts are:
- Collimator: a slit at the focus of a convex lens, producing a parallel beam.
- Turntable: holds a prism or diffraction grating and carries a circular scale with a vernier.
- Telescope: focused for parallel rays, used to view and measure the deviated light.
With a prism set at minimum deviation and prism angle , the refractive index is
With a grating, the wavelength follows from .
7. Michelson's Measurement of the Speed of Light
Michelson used a rotating eight-sided mirror. Light reflected from one face travelled to a distant mirror and back (a round trip of ). The octagonal mirror was spun until the next face arrived in exactly the right position in the time the light took for the round trip, which is of a revolution. If is the rotation frequency,
His results gave a value very close to the modern .
8. Fibre Optics
An optical fibre is a thin glass or plastic core of refractive index surrounded by cladding of lower index . Light entering at a suitable angle strikes the core–cladding boundary at more than the critical angle and is trapped by total internal reflection:
Example: and give , so . Rays must strike the boundary at more than about to the normal.
| Fibre type | Index profile | Behaviour |
|---|---|---|
| Step-index multimode | Uniform core, sharp drop at cladding | Many ray paths of different lengths; pulses spread (dispersion), so suited to short links |
| Graded-index multimode | Index decreases gradually from the axis outward | Outer rays travel faster in lower-index glass and keep pace with axial rays; less dispersion |
| Single-mode | Very thin core (a few micrometres) | Essentially one path; least dispersion, used for long-distance telecommunication |
Signal losses come from absorption by impurities, scattering by tiny variations in the glass, and bending. Signals are restored by repeaters or optical amplifiers along long links. Fibres are lighter than copper, immune to electromagnetic interference, carry far more information, and are used in telephone and internet links, endoscopes and sensors.
An astronomical telescope in normal adjustment has an objective of focal length 120 cm and an eyepiece of focal length 4 cm. What are its magnifying power and length?
30 and 116 cm
480 and 124 cm
30 and 124 cm
34 and 120 cm
A step-index optical fibre has a core of refractive index 1.60 and cladding of refractive index 1.20. What is the critical angle at the core–cladding boundary?
About
About
About
About
Why does a graded-index multimode fibre spread a short light pulse less than a step-index multimode fibre of the same length?
Its core is opaque at the edges, so oblique rays are absorbed
Rays far from the axis travel in lower-index glass, so they move faster and keep pace with axial rays
It uses a higher critical angle, so no ray is ever reflected
Light travels at the vacuum speed of light inside a graded-index core
Sections you finish are checked off in the contents.