11.1 Ultrasound Principles, Transthoracic/Stress Echocardiography & Tilt-Table Testing

Key Takeaways

  • A transducer converts electrical signals into ultrasound and returning echoes into electrical signals. A higher frequency can improve resolution at the cost of penetration.

  • Pulsed Doppler selects a depth and can alias. Continuous-wave Doppler can measure fast jets but cannot assign the signal to one depth.

  • Treadmill stress echo compares rest images with views obtained promptly after exercise. The 2020 ASE guideline calls for acquiring post-exercise images as soon as possible, within one to two minutes.

  • Tilt testing records symptoms with heart rate and beat-to-beat pressure. Orthostatic tachycardia on one test contributes to the evaluation and cannot establish POTS by itself.

Last updated: November 2026

Ultrasound and Doppler

A phased-array transducer sends pulses into tissue and detects returning echoes. Its piezoelectric elements convert electrical energy to mechanical waves and return signals to electrical form. A higher frequency shortens wavelength and can improve resolution, while greater attenuation limits penetration. Choose settings for the depth and patient rather than assuming every probe uses a fixed frequency. Echoes arise at boundaries where acoustic impedance changes. Coupling gel reduces the thin air gap between the probe and skin. For adult transthoracic echocardiography (TTE), the probe uses accessible chest-wall windows to avoid much of the interference from rib and lung. ASE comprehensive adult TTE guideline

The Doppler frequency shift from moving blood depends on the component of velocity along the beam. Align as nearly parallel to flow as possible. A poor angle can underestimate the velocity and therefore the calculated gradient. The simplified Bernoulli relation is ΔP≈4v2\Delta P \approx 4v^2 in mmHg when velocity vv is expressed in m/s and the upstream velocity can reasonably be neglected. A peak velocity of 4.0 m/s across an aortic valve gives a peak instantaneous gradient of 64 mmHg, which is a different measurement from the mean gradient used in valve assessment. In a separate example, a 3.0 m/s tricuspid regurgitant jet and estimated right atrial pressure of 10 mmHg give RV systolic pressure of approximately 46 mmHg. This estimates pulmonary artery systolic pressure if there is no relevant obstruction between the RV and pulmonary artery. An inadequate jet or uncertain right atrial pressure reduces reliability. ASE/EACVI aortic stenosis update 2025 ASE right-heart guideline

ModeWhat it measures or displays
2DCross-sectional anatomy, chambers and wall motion
M-modeMotion along a single ultrasound line over time
Pulsed-wave DopplerVelocity signal at a selected depth. The Nyquist limit depends on pulse repetition frequency and the recorded signal can alias.
Continuous-wave DopplerHigh velocities along the beam, with no single depth of origin
Colour DopplerFlow information over the image. Check the map for the assigned colour and direction.

Echocardiographic windows and test preparation

Left lateral positioning often helps with parasternal and apical TTE views. Parasternal long and short axes show complementary sections through the ventricle and valves. Apical four- and two-chamber views can be used together to estimate LV volumes and EF by the biplane method. The subcostal window is useful for the atrial septum and inferior vena cava in a suitable view. Suprasternal views can show the aortic arch. The ECG time reference helps the operator align images with cardiac cycle events. Follow the imaging team's directions for the patient's actual position and electrode sites. ASE comprehensive TTE guideline

Transoesophageal echocardiography (TEE) images from the oesophagus, close to the left atrium. It can evaluate the left atrial appendage, prosthetic valves and suspected endocarditis when clinically indicated. If TEE is requested before cardioversion to evaluate for thrombus, the close view of the appendage is useful. Confirm the procedural team's preparation, including relevant swallowing history and fasting and sedation instructions, then document ECG and other observations within the assigned role. ASE/SCA comprehensive TEE guideline

Stress echo compares regional wall motion at rest and during or immediately after stress. Exercise and dobutamine can increase myocardial work. New regional dysfunction can support inducible ischaemia. With treadmill testing, capture post-exercise images promptly, within one to two minutes per ASE, because wall motion can normalise during recovery. A bicycle protocol can acquire images during exercise. Follow the team's medication instructions and plan for the specific modality. The 2026 ASNC caffeine guidance for vasodilator myocardial perfusion imaging is a separate preparation pathway. Record symptoms, ECG and pressure according to the echo protocol. ASE stress echo guideline 2026 ASNC SPECT/PET stress guideline

Worked comparison. An ECG is available from both an exercise echo and a tilt study. In the exercise echo, relate any ST changes to the workload and the timing of each image. In the tilt study, match lightheadedness to the simultaneous pressure and rhythm. A rise in rate can be an expected response to standing, so state how large the rise was, how long it lasted and whether pressure fell.

Head-up tilt testing

The team may use tilt to investigate reflex syncope, orthostatic hypotension or orthostatic intolerance. Record the supine baseline and monitor ECG, beat-to-beat pressure and symptoms during the upright phase. Select tilt angle and duration for the question under the approved protocol. A vasovagal episode can include hypotension, cardioinhibition or both. A sustained adult rate increase of at least 30/min within ten minutes without orthostatic hypotension can support evaluation for postural orthostatic tachycardia syndrome (POTS). The diagnosis also requires persistent compatible symptoms and consideration of alternative causes. Report symptomatic pressure or rhythm changes promptly. EFAS autonomic testing consensus NIH expert consensus on POTS

Test Your Knowledge

With appropriate Doppler alignment and negligible upstream velocity, a peak aortic jet velocity is 4.0 m/s. What is the simplified peak instantaneous gradient?

A

16 mmHg

B

64 mmHg

C

32 mmHg

D

128 mmHg

Test Your Knowledge

When imaging is ordered to check the left atrial appendage for thrombus before cardioversion, which study benefits from a probe placed behind the left atrium?

A

Routine subcostal TTE

B

M-mode parasternal TTE

C

Suprasternal notch TTE

D

Transoesophageal echocardiography

Test Your Knowledge

Why does the team acquire post-treadmill stress echo views as soon as possible after exercise?

A

Stress-induced regional wall-motion changes can fade during early recovery

B

Gel ceases coupling the probe as soon as exercise stops

C

Doppler can measure flow only during recovery

D

The transducer automatically switches to M-mode after one minute

Test Your Knowledge

An adult with recurrent upright lightheadedness has a sustained rise from 72 to 114/min within six minutes of tilt. Blood pressure changes from 118/74 to 114/76 mmHg. Which finding can be recorded from this observation?

A

Cardioinhibitory syncope with a pause

B

Vasodepressor syncope with a large pressure drop

C

Orthostatic tachycardia supporting evaluation for POTS

D

Orthostatic hypotension based on the diastolic change

Sections you finish are checked off in the contents.