4.2 Cardiac Biomarkers (Troponin I/T, CK-MB, Myoglobin, BNP/NT-proBNP) & Kinetics

Key Takeaways

  • Reduced oxygen delivery limits oxidative ATP production. Ischaemic myocardium relies more on glycolysis, and severe or prolonged ischaemia can injure cells.

  • The 2026 Universal Definition describes acute myocardial injury as a rise or fall in cardiac troponin I or T with at least one value above the sex-specific 99th percentile for that assay.

  • Acute myocardial infarction requires acute myocardial injury with clinical evidence of acute ischaemia. Troponin elevation alone does not establish its cause.

  • For suspected recurrent infarction, serial cardiac troponin and clinical reassessment are more informative than a single result or routine CK-MB testing.

  • BNP and NT-proBNP help assess suspected heart failure. Read them in context, including age, kidney function, body size, rhythm and medicines.

Last updated: November 2026

A patient can have acute myocardial infarction (MI) without diagnostic ST elevation on the first ECG. Conversely, a high troponin result can reflect injury from causes other than infarction. Compare the clinical findings, ECG and serial laboratory measurements. A diagnostic ECG or an unstable patient needs immediate escalation, without waiting for an injury marker to rise.

Myocardial energy during ischaemia

Working myocardium uses mitochondria to produce much of its adenosine triphosphate (ATP). It can oxidize fatty acids, glucose or lactate, depending on conditions. In ischaemia, blood flow supplies too little oxygen for the workload. Oxidative ATP production falls and the cells rely more on glycolysis. Glycolysis yields two net ATP molecules from one free glucose molecule. Conversion of pyruvate to lactate regenerates the oxidized form of nicotinamide adenine dinucleotide (NAD), allowing glycolysis to continue. Poor washout and changes in cellular metabolism contribute to tissue acidosis. Lactate accumulation accompanies this process, but the production of lactate is not itself the direct source of every excess proton.

Poor energy supply and acidosis can impair calcium handling, ion gradients and contraction. If injury is severe, intracellular proteins can appear in the blood. An electrocardiogram records changes in electrical activity, while a troponin test measures evidence of cell injury. The two tests can change at different times.

Troponin and the current definition

Troponin C binds calcium. Troponin I helps regulate inhibition of actin–myosin interaction, and troponin T attaches the complex to tropomyosin. Clinical cardiac injury assays measure cardiac troponin I (cTnI) or cardiac troponin T (cTnT). High-sensitivity assays can detect small amounts, and their numeric decision limits differ by assay. Use the units and upper reference limit (URL) specified for the reported assay.

FindingMeaning in the 2026 Universal Definition
Serial rise or fall with at least one result above the sex-specific 99th percentile URLAcute myocardial injury
Persistent troponin above the URL without a meaningful acute changePattern consistent with chronic injury after considering timing
Acute injury with evidence of acute ischaemiaEvaluate for MI and establish the clinical mechanism

The Fifth Universal Definition of Myocardial Infarction, issued in August 2026, uses primary, secondary and procedure-related MI categories. A primary MI can follow an acute coronary process such as plaque disruption with thrombosis. A secondary MI can follow an acute supply–demand imbalance from another illness, with evidence of ischaemia. Acute injury can occur without infarction, for example in myocarditis. Imaging can help confirm and classify the mechanism, and the consensus describes how to use clinical, ECG and biomarker evidence if imaging is unavailable.

A single result obtained soon after symptoms began can be misleading. For suspected non-ST-elevation acute coronary syndrome, use the facility’s validated assay-specific serial pathway. The interval between samples and the amount of change considered significant are part of that pathway. Kidney disease and structural heart disease can contribute to an elevated baseline. Interpret the trajectory and clinical findings alongside the concentration.

Older markers and a repeat presentation

MarkerWhat it measures and why it matters
CK-MBAn isoenzyme of creatine kinase that often returns toward baseline sooner than troponin. Skeletal muscle can also contribute. Current practice uses cardiac troponin for routine assessment, including suspected recurrence.
MyoglobinAn early oxygen-binding protein released by both skeletal and cardiac muscle, which limits its specificity for infarction.
AST and LDHEnzymes from several tissues. They were used historically and have been superseded for routine diagnosis.

Suppose the same high-sensitivity cTnI assay reports a decrease from 820 to 340 ng/L after an infarction. Later the patient has renewed chest pain, new regional ECG changes and cTnI of 610 ng/L. The increase from the last sample is 270 ng/L. A renewed rise in this clinical setting raises concern for recurrence. The clinical team also considers complications of the first event, the timing of any procedure and whether coronary imaging is needed. A single persistent elevation cannot distinguish the first event from a new one. The 2026 definition notes that adding routine CK-MB does not clarify this question.

Natriuretic peptides and acute dyspnoea

Myocardial wall stress stimulates release of proBNP. Processing produces active B-type natriuretic peptide (BNP) and N-terminal proBNP (NT-proBNP). These markers address a different question from injury markers. In a patient with shortness of breath, they can support assessment for heart failure alongside the exam, ECG and imaging.

Setting in the 2021 ESC heart failure guidelineLower values make heart failure less likely
Acute presentationBNP below 100 pg/mL or NT-proBNP below 300 pg/mL
Non-acute assessmentBNP below 35 pg/mL or NT-proBNP below 125 pg/mL

These cutoffs are used in diagnostic pathways alongside patient findings. Obesity can lower results, while older age, kidney dysfunction and atrial fibrillation can raise them. NT-proBNP is not a direct neprilysin substrate. It can be easier to interpret when BNP changes during initiation of sacubitril/valsartan, but neither assay eliminates the need for clinical assessment.

Sources: Fifth Universal Definition of MI, §§5–7 and 14 · ACC/AHA 2025 acute coronary syndromes guideline · ESC 2021 acute and chronic heart failure guideline · Experimental study of metabolic responses in low-flow ischaemia · Ischaemia experiments on intra- and extracellular pH

Sources: PARADIGM-HF biomarker analysis

Loading diagram...
Biomarker Selection Across Chest Pain & Dyspnea Timeframes
Test Your Knowledge

When myocardial oxygen supply becomes inadequate, why does metabolically stressed myocardium depend more on glycolysis?

A

Reduced oxygen delivery limits oxidative phosphorylation, so glycolysis supplies a small amount of ATP without directly requiring oxygen

B

Oxygen deficiency makes mitochondrial fatty-acid oxidation faster than normal

C

Oxygen deficiency prevents cells from converting glucose to pyruvate

D

Glycolysis produces ATP only after troponin leaves the cell

Test Your Knowledge

A patient develops new ischaemic symptoms several days after acute MI. Troponin is still above its reference limit. Which laboratory approach best helps assess possible recurrence?

A

Use myoglobin alone to determine if the injury is cardiac

B

Assume any persistent troponin elevation proves new infarction

C

Compare serial cardiac troponin with prior results and consider the new ECG findings and symptoms

D

Substitute a single CK-MB result for the clinical assessment

Test Your Knowledge

Under the 2026 Universal Definition, which result pattern meets the biomarker criterion for acute myocardial injury?

A

A single troponin below the upper reference limit

B

A rise or fall in cardiac troponin I or T with at least one value above the assay’s sex-specific 99th percentile

C

A high BNP despite serial troponin results below the upper reference limit

D

One result for Troponin C with no serial result

Test Your Knowledge

Which statement is appropriate when checking a natriuretic peptide result in an adult with acute dyspnoea who takes sacubitril/valsartan?

A

A BNP below 100 pg/mL confirms acute heart failure

B

Neprilysin degrades NT-proBNP directly, so the value is unusable

C

Myoglobin is preferred because it measures ventricular wall stress

D

NT-proBNP is not a direct neprilysin substrate, and a value below 300 pg/mL makes acute heart failure less likely in the ESC diagnostic pathway

Sections you finish are checked off in the contents.