3.3 Cardiac Cycle Phases, Pressure-Volume Loops & Heart Sounds (S1-S4)

Key Takeaways

  • At 75 beats/min, a cardiac cycle lasts 0.80 seconds. As rate rises, diastole usually shortens more than systole.

  • The left ventricular pressure–volume loop starts isovolumetric contraction at mitral closure and isovolumetric relaxation at aortic closure. Both phases occur with the mitral and aortic valves closed.

  • Compare right- and left-sided pressures in context. Pulmonary artery wedge pressure estimates left atrial pressure when the measurement is valid.

  • The jugular venous a wave reflects atrial contraction. The v wave rises as the right atrium fills while the tricuspid valve is closed.

  • S1 occurs near the start of systole and S2 near the end. S3 accompanies early filling and S4 requires organized atrial contraction.

Last updated: November 2026

While the ECG captures the heart's electrical trigger, the cardiac cycle describes the resulting mechanical sequence of pressure changes, valve openings and closures, volume shifts, and heart sounds. At a resting heart rate of 75 bpm75\text{ bpm}, each complete cycle lasts 60/75=0.80 s60 / 75 = 0.80\text{ s} (800 ms800\text{ ms}), split into approximately 0.30 s0.30\text{ s} of ventricular systole and 0.50 s0.50\text{ s} of ventricular diastole. Crucially, when heart rate climbs sharply during tachycardia, diastole shortens much more than systole—squeezing both passive ventricular filling time and left ventricular coronary perfusion (which occurs predominantly during diastole when myocardial wall tension drops).

The 7 Phases of the Cardiac Cycle (Wiggers Diagram)

The Wiggers diagram places electrical and mechanical events on the same timeline. Use the ECG as an approximate reference because valve motion and heart sounds follow changes in pressure, not a fixed point on the ECG. In these illustrative adult volumes:

  1. Atrial Systole (Late Diastole / Atrial Kick): Preceded by the P wave, atrial contraction adds to ventricular filling (the atrial kick), raising ventricular volume to its maximum end-diastolic volume (EDV≈120 mL\text{EDV} \approx 120\text{ mL}). It generates the 'a' wave on the atrial and jugular venous pressure (JVP) tracings and, in a stiff ventricle, an S4 heart sound.
  2. Isovolumetric Contraction: Shortly after ventricular activation begins, ventricular pressure rises above the upstream atrial pressure, snapping the mitral and tricuspid (AV) valves shut and producing the S1 heart sound (lub). Because the aortic and pulmonic (semilunar) valves are not yet open, the inlet and outlet valves for each ventricle are closed during its isovolumetric phase: ventricular volume stays locked at EDV (120 mL120\text{ mL}) while LV pressure rockets from 8 mmHg8\text{ mmHg} to 80 mmHg80\text{ mmHg}. Bulging of the closed tricuspid valve into the right atrium creates the 'c' wave on the JVP.
  3. Rapid Ejection: Once LV pressure exceeds aortic diastolic pressure (≈80 mmHg\approx 80\text{ mmHg}) and RV pressure exceeds pulmonary artery diastolic pressure (≈10 mmHg\approx 10\text{ mmHg}), the semilunar valves open silently. Pressure peaks (LV/Aorta ≈120 mmHg\text{LV/Aorta } \approx 120\text{ mmHg}; RV/PA ≈25 mmHg\text{RV/PA } \approx 25\text{ mmHg}), and a large portion of stroke volume leaves during rapid ejection, around the ST segment. Downward descent of the AV valve ring and atrial relaxation produce the JVP 'x' descent.
  4. Reduced Ejection: Coinciding with the T wave, active contraction fades as repolarization begins. Ventricular pressure dips slightly below aortic pressure, yet forward outflow continues briefly due to fluid kinetic momentum while blood simultaneously pools behind closed AV valves in the atria, inscribing the rising 'v' wave.
  5. Isovolumetric Relaxation: Near the end of ventricular systole, the arterial pressure becomes greater than the falling ventricular pressure and the aortic and pulmonary valves close, producing the S2 heart sound (dub) and the dicrotic notch (incisura) on the aortic pressure curve. With both valves of each ventricle closed during its isovolumetric interval, volume stays constant at end-systolic volume (ESV≈50 mL\text{ESV} \approx 50\text{ mL}) as LV pressure plunges rapidly.
  6. Rapid Ventricular Filling: Each atrioventricular valve opens when its ventricular pressure drops below the corresponding atrial pressure. Blood accumulated in the atria flows rapidly into the ventricles, creating the JVP 'y' descent and, when ventricular compliance is altered or flow is brisk, the S3 heart sound.
  7. Reduced Ventricular Filling (Diastasis): The slowest phase of mid-diastole during which venous return flows steadily through open AV valves until the next P wave restarts atrial systole.
Cardiac Cycle PhaseApproximate ECG TimingValve Status for Each VentriclePressure & Volume EventHeart Sound / JVP Wave
1. Atrial SystoleP wave to PR segmentAV open; SL closedAtrial contraction completes filling to EDV (~120 mL)S4 (if stiff LV); JVP a wave
2. Isovolumetric ContractionQRS complexInlet and outlet closedAV closure; LV pressure spikes 8→80 mmHg8 \rightarrow 80\text{ mmHg} at constant EDVS1 (M1,T1M_1, T_1); JVP c wave
3. Rapid EjectionST segmentAV closed; SL openSL valves open; peak LV/Aorta 120 mmHg120\text{ mmHg}; fast outflowNormal silent; JVP x descent
4. Reduced EjectionOften overlaps the T waveAV closed; SL openMomentum-driven outflow; atria fill passivelyNormal silent; JVP v wave rises
5. Isovolumetric RelaxationAround the end of ventricular repolarizationAll 4 valves closedSL closure; aortic dicrotic notch; LV pressure plunges at constant ESV (~50 mL)S2 (A2,P2A_2, P_2)
6. Rapid FillingTP segment (early)AV open; SL closedAV valves open; Rapid passive fillingS3 (if rapid/overload); JVP y descent
7. Reduced Filling (Diastasis)TP segment (late)AV open; SL closedSlow passive filling plateau before next P waveSilent

Normal Intracardiac & Great Vessel Pressures

The examples below illustrate resting pressure relationships for a single adult profile. Use the clinical team’s reference ranges and measurement conditions to interpret catheter readings:

Chamber / VesselSystolic / Diastolic (mmHg)Mean Pressure (mmHg)Clinical Landmark
Right Atrium (RA / CVP)a/v waves 2–844Pressure in the right atrium approximates central venous pressure under appropriate measurement conditions
Right Ventricle (RV)25/425 / 4—Low-pressure pump driving pulmonary circuit
Pulmonary Artery (PA)25/1025 / 10≈15\approx 15Pulmonary hypertension defined as mean PA >20 mmHg> 20\text{ mmHg}
Left Atrium (LA / PCWP)Varies over the cycle88Pulmonary artery wedge pressure (PAWP, also called PCWP) estimates mean left atrial pressure when measured appropriately
Left Ventricle (LV)120/8120 / 8 (peak systolic / end-diastolic)—End-diastolic pressure depends on both filling and ventricular compliance
Aorta120/80120 / 80≈93\approx 93 (simple resting estimate)Systolic matches LV peak (absent aortic stenosis); diastolic maintains coronary flow

Left Ventricular Pressure-Volume (PV) Loop & JVP Waveforms

Plotting left ventricular pressure (y-axis) against left ventricular volume (x-axis) yields a counterclockwise Pressure-Volume (PV) loop whose four corners represent valve transitions:

  • Bottom-right corner: Mitral valve closes (S1) at EDV≈120 mL\text{EDV} \approx 120\text{ mL} and LVEDP≈8 mmHg\text{LVEDP} \approx 8\text{ mmHg}.
  • Right vertical border: Isovolumetric contraction (volume unchanged at 120 mL120\text{ mL}) until aortic valve opens at the top-right corner (≈80 mmHg\approx 80\text{ mmHg}).
  • Top curve: Systolic ejection, peaking near 120 mmHg120\text{ mmHg} and ending at the top-left corner where the aortic valve closes (S2) at ESV≈50 mL\text{ESV} \approx 50\text{ mL}.
  • Left vertical border: Isovolumetric relaxation (volume unchanged at 50 mL50\text{ mL}) down to the bottom-left corner where the mitral valve opens (≈8–10 mmHg\approx 8\text{–}10\text{ mmHg}).
  • Width and Area: Loop width equals Stroke Volume (SV=EDV−ESV=120−50=70 mL\text{SV} = \text{EDV} - \text{ESV} = 120 - 50 = 70\text{ mL}), giving an Ejection Fraction of 70/120×100%≈58.3%70 / 120 \times 100\% \approx 58.3\%. The enclosed loop area represents external stroke work. The slope of the line connecting end-systolic points (ESPVR, EesE_{es}) is an index of contractility when estimated from a series of loops at different loads.

On the jugular venous pulse (JVP), absence of the a wave characterizes atrial fibrillation (loss of coordinated atrial kick), whereas giant cannon 'a' waves occur in complete (3rd-degree) AV block or VT when the right atrium contracts against a closed tricuspid valve. Prominent v waves may accompany tricuspid regurgitation. A rapid y descent can accompany constrictive pericarditis. Neither sign alone establishes a diagnosis.

Auscultatory Heart Sounds (S1–S4) & Physiological Splitting

Normal valves open silently; audible heart sounds arise from abrupt deceleration of blood columns and vibration of leaflets/walls when valves close or ventricles fill rapidly:

  • S1 (Lub): Caused by mitral (M1M_1) followed closely by tricuspid (T1T_1) valve closure early in ventricular systole, shortly after QRS onset. It can be louder when mitral leaflets remain wide apart at contraction onset (short PR interval, early mitral stenosis) and softer in 1st-degree AV block (long PR interval) or severe mitral regurgitation.
  • S2 (Dub): Caused by aortic (A2A_2) followed by pulmonic (P2P_2) valve closure near the end of ventricular systole. During normal inspiration, changes in right-sided filling and pulmonary vascular impedance delay P2P_2. A2A_2 can move slightly earlier—producing physiological inspiratory splitting (A2A_2 and P2P_2 separate during inspiration and move closer during expiration). By contrast, wide fixed splitting occurs in atrial septal defect (ASD), and paradoxical (reversed) splitting (splitting on expiration, merging on inspiration) occurs in left bundle branch block (LBBB) or severe aortic stenosis where delayed LV ejection pushes A2A_2 past P2P_2.
  • S3 (Ventricular Gallop, Ken-tuc-ky): Low-pitched sound heard best with the stethoscope bell at the apex during early diastole (rapid ventricular filling). It can be physiological in children, young adults or pregnancy. In an older or symptomatic adult it can suggest abnormal filling or volume overload and warrants clinical correlation.
  • S4 (Atrial Gallop, Ten-nes-see): Low-pitched sound heard with the bell during late diastole (atrial systole) as the atria force blood into a stiff, non-compliant ventricle (e.g., chronic hypertension, concentric LV hypertrophy, aortic stenosis, acute myocardial ischemia). Because S4 requires coordinated atrial contraction, S4 cannot exist in atrial fibrillation.

Sources: OpenStax Cardiac Cycle · Suga and Sagawa ventricular pressure–volume experiments · ESC/ERS pulmonary hypertension guideline · Shaver and colleagues, Second Heart Sound

Test Your Knowledge

Which combination accurately pairs a cardiac valve transition with its ECG landmark, pressure-volume loop corner, and auscultatory sound?

A

Mitral closure just after ventricular activation begins occurs at the bottom-right corner of the left ventricular loop and contributes to S1

B

Aortic valve opening at the P wave corresponds to the top-left corner (ESV ~50 mL) and generates S2

C

Tricuspid valve opening during isovolumetric contraction generates the aortic dicrotic notch and S4

D

Mitral valve opening at the end of the T wave marks the top-right corner and generates S1

Test Your Knowledge

Why does physiological splitting of the second heart sound (S2) widen during inspiration in a healthy adult?

A

Inspiration raises intrathoracic pressure, hastening pulmonic valve closure (P2) ahead of aortic closure (A2)

B

Inspiration increases sympathetic tone solely to the left ventricle, delaying A2 while P2 stays fixed

C

Inspiration delays pulmonary valve closure relative to aortic closure, widening the A2–P2 interval

D

Inspiration causes premature mitral closure (M1) during the ST segment

Test Your Knowledge

An adult with long-standing untreated hypertension and concentric left ventricular hypertrophy presents in normal sinus rhythm with an extra low-pitched sound heard just before S1. Which mechanism explains this finding, and what happens to it if the patient develops atrial fibrillation?

A

An S3 gallop from rapid early diastolic filling; it grows louder in atrial fibrillation

B

An S4 atrial gallop caused by forceful atrial contraction into a stiff, non-compliant ventricle; it disappears in atrial fibrillation

C

Physiological S2 splitting from delayed A2 closure; it reverses during atrial fibrillation

D

Mitral opening snap caused by low left atrial pressure; it merges with S1

Test Your Knowledge

A patient with complete (third-degree) AV block develops intermittent giant 'cannon a waves' on the jugular venous pulse (JVP) tracing. What produces these waves?

A

Passive right atrial filling during late systole across an incompetent tricuspid valve

B

Rapid passive emptying of the right atrium in constrictive pericarditis

C

Downward pulling of the tricuspid annulus during early right ventricular ejection

D

Right atrial contraction occurring against a closed tricuspid valve during ventricular systole

Sections you finish are checked off in the contents.