7.1 Sinus Rhythms, PACs, Atrial Fibrillation, Atrial Flutter & SVT
Key Takeaways
Abnormal automaticity, triggered activity and re-entry are major mechanisms. Calcium overload can drive delayed afterdepolarisations during digoxin toxicity.
Sinus beats have consistent P-wave morphology. A premature atrial beat can distort the preceding T wave and reset sinus timing.
Atrial fibrillation usually has irregularly irregular ventricular timing and no discrete P waves. Typical flutter can show repeating inferior sawtooth waves and a regular ventricular rate near 150/min with 2:1 conduction.
Multifocal atrial tachycardia has clearly distinct P-wave shapes and atrial rate above 100/min. In typical AVNRT, retrograde atrial activity can be hidden in the QRS.
Three arrhythmia mechanisms
Automaticity means spontaneous impulse formation. The sinoatrial node uses several interacting currents to depolarise between beats. Adrenergic stimulation can increase its rate. Automatic activity can also arise outside the sinus node. A rise and fall in rate over several beats can suggest automatic tachycardia, while abrupt onset and offset can suggest re-entry. Timing is a clue alongside the P-wave pattern and conduction relationship. 2019 ESC supraventricular tachycardia guideline
Triggered activity begins with a preceding action potential. Early afterdepolarisations interrupt repolarisation and are one mechanism of torsades de pointes in the setting of prolonged repolarisation. Delayed afterdepolarisations occur after repolarisation. Digoxin inhibits sodium-potassium ATPase and can increase intracellular calcium. Calcium overload can generate a transient inward current and, if the resulting depolarisation reaches threshold, an ectopic beat. Purkinje fibre study of digitalis-associated triggered activity ESC ventricular arrhythmia guideline
Re-entry involves a wavefront that can travel around a circuit and re-excite recovered tissue. When a premature wavefront is blocked in one direction, slow enough conduction along another route can allow the first route to recover before the wave returns. Typical AV nodal re-entry, AV re-entry using an accessory pathway and typical flutter illustrate circuits of different sizes. 2019 ESC supraventricular tachycardia guideline
Sinus rhythm, pauses and premature atrial beats
Start by finding discrete P waves. A typical sinus P is upright in I and II and negative in aVR. Regular adult sinus rhythm at rest is commonly described as 60–100/min. Ordinary sinus conduction gives one P wave before each QRS and a PR usually between 120 and 200 ms. At 25 mm/s, the usual PR range is three to five small boxes. Sinus activation can coexist with AV block, so identify the atrial source and AV conduction separately. During respiratory sinus arrhythmia, the rate generally rises with inspiration and slows with expiration without a change in P-wave shape. Sinus slowing can be physiological in sleep or athletic training. Sinus acceleration may accompany exercise, pain, fever, anaemia or low circulating volume. 2019 ESC supraventricular tachycardia guideline 2018 ACC/AHA/HRS bradycardia guideline
For an apparent pause, look for a P wave hidden in the preceding T wave and compare several beats. A premature atrial complex (PAC) may conduct with a narrow QRS, conduct with aberrancy or encounter refractory tissue and fail to conduct. A PAC can reset the sinus node. If the interval between the sinus P waves that bracket the PAC is shorter than twice the stable baseline P–P interval, it is an incomplete or non-compensatory pause. A pause that is approximately an integer multiple of the sinus cycle can suggest sinoatrial exit block, but interval timing alone does not establish the mechanism. A pause after termination of AF can be seen with sinus node dysfunction. Assess timing, symptoms and other causes. A single pause duration cannot establish that diagnosis. Atrial and ventricular stimulation study Blocked PAC clinical tracing Bradycardia guideline
Irregular and regular atrial rhythms
| Rhythm | What to look for | How to interpret it |
|---|---|---|
| Multifocal atrial tachycardia (MAT) | At least three distinct P-wave shapes in a single lead, an isoelectric baseline between them and irregular timing | The atrial rate is above 100/min. With similar morphology at a slower rate, the pattern is termed wandering atrial pacemaker. MAT can occur with severe pulmonary disease. |
| Atrial fibrillation (AF) | No consistent discrete P waves and irregularly irregular R–R intervals when AV conduction is intact | Fibrillatory activity may be subtle. A slow regular ventricular response during AF warrants assessment for conduction block or a paced/escape rhythm. |
| Typical atrial flutter | Repetitive atrial waves, often negative and sawtooth-shaped in II, III and aVF in the common counterclockwise circuit | Fixed AV conduction produces a regular ventricular rhythm. Variable conduction may produce irregular ventricular timing. |
| Typical AVNRT | Regular tachycardia and retrograde atrial activity close to or within the QRS | A new terminal pseudo-r′ in V1 or pseudo-S in inferior leads can help identify it. Their absence does not rule it out. |
| Orthodromic AVRT | Usually a regular narrow QRS and a retrograde P wave after or near the QRS | Conduction travels down the AV node and back to the atria through an accessory pathway. The atrial timing depends on pathway location and conduction. |
Worked example. A regular narrow tachycardia has a ventricular rate of 150/min and repetitive atrial waves every 200 ms in the inferior leads. That is 300 atrial activations per minute and one ventricular response for every two atrial activations. One flutter wave can be buried in the QRS or T wave, so inspect more than one lead. Transient AV block during supervised adenosine use can reveal continuing flutter waves. In AVNRT or AVRT, blocking the AV node can terminate a circuit that requires it. Capture the transition when the treating team uses the adult algorithm. Treatment eligibility depends on stability, QRS width, regularity and possible pre-excitation. 2019 ESC supraventricular tachycardia guideline 2024 ESC atrial fibrillation guideline 2025 AHA adult advanced life support
In digoxin toxicity, which cellular event can trigger an ectopic beat after the preceding action potential has repolarised?
Early afterdepolarizations (EADs) occurring in phase 2–3 due to potassium channel blockade
Delayed afterdepolarizations (DADs) occurring in phase 4 due to intracellular Ca2+ overload
Accelerated spontaneous phase 4 funny-current depolarization inside healthy sinoatrial nodal cells
Anatomical macro-reentry around the cavotricuspid isthmus independent of preceding action potentials
A regular narrow tachycardia has a ventricular rate of 150/min. Temporary AV block during supervised testing reveals continuous inferior sawtooth waves at about 300/min while the atrial rhythm persists. What was the initial rhythm?
Typical slow-fast AV nodal reentrant tachycardia (AVNRT)
Multifocal atrial tachycardia secondary to acute COPD exacerbation
Atrial fibrillation with rapid ventricular response and Ashman aberrancy
Atrial flutter with 2:1 AV conduction
On a rhythm strip with a baseline sinus P-P interval of 800 ms (75 bpm), an early ectopic P' wave appears at 520 ms and conducts with a narrow QRS, followed by a pause before the next sinus P wave. Measuring from the pre-ectopic sinus P wave to the post-ectopic sinus P wave gives 1,350 ms. How is this pause classified and why?
A non-compensatory (incomplete) pause characteristic of a PAC that penetrated and reset the sinoatrial node
A full compensatory pause characteristic of a PAC that left the sinoatrial node completely undisturbed
Sinoatrial exit block Type II because the encompassing interval is an exact multiple of the baseline cycle
An interpolated ectopic beat because the sinus cycle length remained completely unchanged
A 68-year-old man hospitalized for severe COPD exacerbation has a heart rate of 128 bpm. Every visible P wave is conducted. His lead II rhythm strip demonstrates irregular R-R intervals, an isoelectric baseline, and four clearly distinct P-wave morphologies with varying PR intervals. Which rhythm is present?
Atrial fibrillation with coarse fibrillatory waves
Wandering atrial pacemaker
Multifocal atrial tachycardia (MAT)
Respiratory sinus arrhythmia
Sections you finish are checked off in the contents.