3.2 Excitation-Contraction Coupling, Dipole Vectors & P-QRS-T Genesis
Key Takeaways
Cardiac excitation-contraction coupling relies on extracellular trigger Ca2+ influx through T-tubule L-type channels (DHPR) to open SR ryanodine receptors (RyR2) via calcium-induced calcium release (CICR)
SERCA2a pumps calcium back into the sarcoplasmic reticulum, while the sodium–calcium exchanger removes calcium across the cell membrane. Phospholamban regulates SERCA2a.
A depolarization vector produces a positive deflection when it points toward a lead’s positive pole, a negative deflection when it points away, and zero instantaneous projection when perpendicular.
The electrical polarity of recovery is opposite that of activation. If recovery also proceeds in the opposite direction, the T wave and QRS can have the same predominant polarity in a lead.
The PR interval includes atrial and atrioventricular conduction. The ST segment reflects the early part of ventricular recovery, and a prominent U wave can accompany hypokalaemia.
How does a microscopic transmembrane voltage shift generate both a powerful heartbeat and a reproducible P-QRS-T waveform on the skin? Two bridges connect cellular electrophysiology to clinical cardiology: excitation-contraction coupling (ECC) translates electrical depolarization into sarcomere shortening, while a lead-axis projection explains why the same cardiac event can produce different deflections in different leads.
Excitation-Contraction Coupling (ECC) & Relaxation
Unlike skeletal muscle—where T-tubule voltage sensors mechanically pull open sarcoplasmic reticulum (SR) calcium channels without requiring extracellular calcium entry—cardiac muscle absolutely requires extracellular to contract:
- Action Potential Entry into T-Tubules: The Phase 0 depolarization wave races across the sarcolemma and dives deep into transverse (T) tubules, invaginations positioned directly adjacent to the terminal cisternae of the sarcoplasmic reticulum.
- Calcium-Induced Calcium Release (CICR): Depolarization opens L-type channels (dihydropyridine receptors, DHPR) during Phase 2. A modest influx of trigger () enters the narrow dyadic cleft and binds to ryanodine receptors (RyR2) on the SR membrane, causing RyR2 channels to burst open and release a massive surge of stored into the cytosol.
- Cross-Bridge Cycling & Force Generation: Cytosolic binds Troponin C (TnC) on the thin actin filament, shifting the troponin-tropomyosin complex aside to expose myosin-binding sites on actin. Myosin heads cycle through ATP-dependent binding and release. The power stroke pulls the thin filaments inward and shortens the sarcomere.
- Active Relaxation (Lusitropy): As Phase 2 ends and inactivates, two transport systems clear cytosolic so dissociates from TnC and the myocardium relaxes:
- SERCA2a (-ATPase): Uses ATP to pump much of the released back into the SR lumen at the expense of ATP. Unphosphorylated phospholamban (PLB) brakes SERCA2a; sympathetic -adrenergic stimulation activates protein kinase A (PKA) to phosphorylate PLB, releasing that brake and accelerating relaxation (positive lusitropy).
- Exchanger (NCX) & PMCA: In its extrusion mode, NCX moves cytosolic out of the cell by importing for every exported, with minor assistance from sarcolemmal -ATPase (PMCA).
Note
Cardiac Glycoside Mechanism (Digoxin): Digoxin inhibits the sarcolemmal -ATPase, elevating intracellular . Because the inward gradient weakens, NCX extrudes less during diastole, leaving more to be sequestered by SERCA2a into the SR. Subsequent beats release larger SR transients, increasing contractility (positive inotropy).
Electrical Dipole Theory & Lead Vector Projection
When the myocardium is uniformly at rest, the net voltage difference due to cardiac activation is small. The tracing is near its baseline.
When a depolarization wave advances across myocardium, depolarized cells behind the wavefront become negative on the outside while resting cells ahead remain positive on the outside. This boundary forms a moving electrical dipole whose dipole vector points from negative to positive—meaning in the same direction as the spreading depolarization wave. In a simplified model, a lead records a projection of the net cardiac vector. A vector of size at angle to the positive lead axis has the projection:
This geometric relationship yields three bedrock ECG rules:
- Wavefront moving toward the positive electrode (, ): Records an upward (positive) deflection.
- Wavefront moving away from the positive electrode (, ): Records a downward (negative) deflection.
- Wavefront moving perpendicular to the lead axis (, ): Has zero projection at that instant. If the vector changes direction during the wave, positive and negative deflections can both appear.
By contrast, during repolarization, restoring the positive exterior places negative exterior charges ahead of the wavefront and positive charges behind it. Consequently, a repolarization dipole vector points opposite to the physical direction of repolarization travel.
Why a positive QRS often has a positive T wave
Rapid activation reaches much of the inner ventricular wall through the Purkinje system and then spreads through the working wall. In a simplified example, a net activation front travels toward a lead’s positive pole and produces a positive QRS deflection. If the recovery front travels in the reverse physical direction, its reversed electrical sign yields a positive T wave in the same lead.
The actual T wave also depends on the distribution of action potential durations and activation times across the ventricles, including regional gradients beyond wall depth. Upright T waves are common in left lateral leads. An inverted T wave must be interpreted by lead, age, tracing and patient context. It has several possible causes, including ischaemia and altered ventricular activation.
Mapping Cellular Events to Surface ECG Components
The surface ECG sums signals over the whole heart. The links below are useful approximations rather than direct measurements of one cell.
| ECG Component | Normal Duration / Feature | Cellular & Anatomical Correlate |
|---|---|---|
| P wave | Duration ; amplitude in limb leads | Atrial depolarization (Phase 0 ): right atrium activates slightly before left atrium; SA node firing itself is too low-voltage to appear |
| PR interval | (onset of P to onset of QRS) | Total time for atrial depolarization plus conduction through AV node, Bundle of His, and Purkinje network |
| PR segment | Isoelectric line from end of P to start of QRS | Much of this interval reflects slow AV nodal conduction and transmission through the proximal ventricular conduction system |
| QRS complex | Duration () | Ventricular depolarization (Phase 0 ): (1) left-to-right septal vector (small lateral Q, small R); (2) dominant LV apical/free-wall vector; (3) basal vector. Obscures atrial repolarization ( wave) |
| ST segment | Isoelectric from J-point to T-wave onset | Ventricles are broadly depolarized and the net voltage difference across the body surface is generally small |
| T wave | Asymmetric (gentler upslope, steeper downslope); concordant with QRS | Net ventricular repolarization, as activation regions recover at different times |
| U wave | Small positive deflection () best seen in | Often more visible with a slow rate. A prominent U wave can accompany hypokalaemia, and its precise physiological origin is uncertain. |
Atrial repolarization is usually too small to identify on a standard ECG and is often obscured by the QRS. With independent atrial and ventricular activity it can sometimes be seen separately. Distinguish this atrial signal from the U wave, which follows the ventricular T wave.
Sources: Experimental local control of cardiac calcium release · Cardiac excitation–contraction coupling · ECG technical statement · ECG standards for ST, T and U waves
What triggers the massive release of stored calcium from the sarcoplasmic reticulum (SR) into the cytosol of a ventricular myocyte during Phase 2?
Direct mechanical tethering between T-tubule voltage sensors and RyR1 without extracellular Ca2+ entry
Rapid Na+ influx through Na_v1.5 channels binding directly to troponin C
Trigger Ca2+ entering through T-tubule L-type Ca2+ channels binding to SR ryanodine receptors (RyR2)
Activation of SERCA2a pumps driven by inward-rectifier I_K1 current
In a simplified ventricular model the activation front travels toward the positive pole of a lead, while recovery spreads in the opposite physical direction. Why can both deflections be positive?
Repolarization has the opposite electrical sign from depolarization, so the reverse physical direction also reverses the sign of the recorded projection
Both depolarization and repolarization spread from epicardium to endocardium while carrying identical external charge polarity
The T wave actually reflects atrial repolarization rather than ventricular Phase 3 potassium efflux
Ventricular repolarization travels perpendicularly to leads I and V5–V6, maximizing cosine theta
In a resting patient with a normal ECG, which cellular state explains why the ST segment sits flat on the isoelectric baseline?
All ventricular myocytes are resting stably at -90 mV during Phase 4
Impulses are trapped inside the AV node during slow L-type Ca2+ conduction
Rapid Phase 0 Na+ channels are firing asymmetrically across the interventricular septum
Much of the ventricular myocardium remains depolarized, producing a small net voltage gradient in the recording
A patient with potassium of 2.6 mmol/L has flattened T waves and an unusually visible deflection after the T wave in V2–V4. What is the post-T deflection called?
Late atrial depolarization delayed inside Bachmann's bundle
A prominent U wave
Premature SA nodal firing occurring during ventricular isovolumetric contraction
Unmasked atrial repolarization (Ta wave) occurring before the QRS complex