PracticeVideosBlogFlashcards
All Practice Exams

Free Practice Questions for AR Electrician

Exam-style questions and explanations by OpenExamPrep.

✓ No registration✓ No credit card
446+ Questions
100% Free
Same family resources

Explore More Electrician License

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.

Exam Review

Key Facts: AR Electrician Exam

70%

Passing Score

Prov bulletin

60

Questions

180-minute limit

$80

Exam Fee

Prov (CBT; $56 paper)

NEC 2023

Open-Book Reference

Prov bulletin

Arkansas requires passing a 60-question, open-book journeyman electrician exam administered by Prov, with 180 minutes and a 70% passing score. Prov's bulletin lists the 2023 NEC as the open-book reference, while Arkansas adopted the 2026 NEC as its statewide standard on September 3, 2026. The exam fee is $80 computer-based or $56 on paper.

Sample AR Electrician Practice Questions

Try these sample questions to review concepts for the AR Electrician exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 446+ question experience with AI tutoring.

1According to the NEC 2023 as adopted by Arkansas, what is the definition of a 'branch circuit'?
A.The circuit conductors between the final overcurrent device and the outlet(s)
B.The circuit conductors between the service point and the main disconnect
C.The circuit conductors between the transformer and the service entrance
D.The circuit conductors between two panelboards
Explanation: Per NEC Article 100, a branch circuit is defined as the circuit conductors between the final overcurrent device protecting the circuit and the outlet(s). This is fundamental to understanding electrical system layout.
2Under Arkansas's NEC 2023 adoption, what is the definition of a 'continuous load'?
A.A load operating for 1 hour or more
B.A load where maximum current continues for 3 hours or more
C.Any load that operates continuously
D.A load exceeding 80% of circuit capacity
Explanation: Per NEC Article 100, a continuous load is one where the maximum current is expected to continue for 3 hours or more. This affects sizing of conductors and overcurrent devices.
3Per the NEC 2023 as adopted in Arkansas, what is the minimum headroom required for working spaces about electrical equipment rated 600V or less?
A.6 feet
B.6 feet 3 inches
C.6 feet 6 inches
D.7 feet
Explanation: Per NEC Section 110.26(A)(3), the minimum headroom for working spaces around electrical equipment rated 600V or less is 6 feet 6 inches (6.5 feet), or the height of the equipment, whichever is greater.
4According to the NEC 2023 adopted by Arkansas, what is the required working space width in front of electrical equipment?
A.24 inches minimum
B.30 inches or the width of the equipment, whichever is greater
C.36 inches minimum
D.48 inches minimum
Explanation: Per NEC Section 110.26(A)(2), the working space width must be at least 30 inches or the width of the equipment, whichever is greater.
5Per NEC 2023 in Arkansas, what is the minimum depth of working space for Condition 1 at 0-150V to ground?
A.2.5 feet
B.3 feet
C.3.5 feet
D.4 feet
Explanation: Per NEC Table 110.26(A)(1), Condition 1 (exposed live parts on one side only) for equipment rated 0-150V to ground requires a minimum working space depth of 3 feet.
6In Arkansas, what is the minimum trade size for EMT per the NEC?
A.1/4 inch
B.3/8 inch
C.1/2 inch
D.3/4 inch
Explanation: Per NEC Section 358.20(A), the minimum trade size for EMT is 1/2 inch (metric designator 16).
7Per the NEC 2023 adopted in Arkansas, what is the maximum height for the center of a disconnect handle?
A.5 feet 6 inches
B.6 feet
C.6 feet 7 inches
D.7 feet
Explanation: Per NEC Section 404.8(A), the center of the operating handle must not be more than 6 feet 7 inches (2.0 m) above the floor when in its highest position.
8Per NEC 2023 in Arkansas, what is the maximum flexible cord length for a garbage disposal?
A.18-36 inches
B.24-48 inches
C.12-24 inches
D.36-60 inches
Explanation: Per NEC Section 422.16(B)(1), a cord-connected garbage disposal must use a flexible cord between 18 and 36 inches in length.
9Under Arkansas's NEC adoption, what is the minimum conductor size for a 20-ampere branch circuit?
A.14 AWG copper
B.12 AWG copper
C.10 AWG copper
D.8 AWG copper
Explanation: Per NEC Section 210.3 and Table 210.3, a 20-ampere branch circuit requires a minimum of 12 AWG copper.
10Per the NEC 2023 in Arkansas, what is the minimum conductor size for a 15-ampere branch circuit?
A.18 AWG
B.16 AWG
C.14 AWG copper
D.12 AWG copper
Explanation: Per NEC Section 210.3, the minimum conductor size for a 15-ampere branch circuit is 14 AWG copper.

About the AR Electrician Exam

The Arkansas journeyman electrician exam is administered by Prov, Inc. for the Arkansas Board of Electrical Examiners. It has 60 open-book questions in 180 minutes, with the 2023 NEC listed as the open-book reference, across grounding and bonding, trade knowledge and calculations, services and overcurrent protection, raceways, conductors, motors, general-use equipment, special occupancies, low-voltage circuits and safety.

Exam sponsor: Arkansas Dept. of Labor & Licensing. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Questions

60 questions

Time Limit

180 minutes

Passing Score

70%

Exam / Certification Fees

$80 CBT / $56 paper

Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

10%

Grounding and Bonding

6 questions: grounding electrode systems, equipment grounding and bonding

15%

General Knowledge of the Electrical Trade and Calculations

9 questions: electrical theory, units and calculations

13%

Service, Feeders, Branch Feeders and Overcurrent Protection

8 questions: services, feeders, branch circuits and overcurrent devices

13%

Raceways and Enclosures

8 questions: raceways, boxes, cabinets and cable trays

12%

Conductors

7 questions: conductor types, insulation and ampacity

12%

Motors and Controls

7 questions: motor circuits, disconnecting means and controllers

10%

Utilization and General Use Equipment

6 questions: switches, receptacles, cords, luminaires and appliances

7%

Special Occupancies and Equipment

4 questions: hazardous locations, pools, information technology rooms and other special equipment

3%

Low Voltage Circuits, Including Alarms and Communications

2 questions: Class 1, 2 and 3 circuits, fire alarms and communications

5%

Safety

3 questions: electrical safety practices

Preparing for the AR Electrician Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 60 questions
  • Time limit: 180 minutes
  • Exam / certification fees: $80 CBT / $56 paper Official sources

Using Our Practice Resources

  • Work through all 446 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

AR Electrician: Suggested Study Strategy

1Master NEC Article 250 (Grounding and Bonding) — 6 of the 60 questions
2Practice dwelling unit load calculations per NEC Article 220
3Memorize conductor ampacity from Table 310.16 at 75°C
4Study conduit fill using NEC Chapter 9 tables
5Review motor circuit requirements in Article 430

Frequently Asked Questions

What NEC edition does Arkansas use?

Prov's bulletin (effective October 31, 2026) lists the 2023 NEC as the open-book reference for the journeyman exam and permits older or newer editions in the testing room. Arkansas adopted the 2026 NEC, with state amendments on AFCI and GFCI protection, as its statewide standard on September 3, 2026.

Who administers the Arkansas electrician exam?

The exam is administered by Prov, Inc. for the Arkansas Board of Electrical Examiners. Register and schedule at provexam.com/scheduler and test at one of Prov's 10 Arkansas centers or remotely.

Is the exam open book?

Yes. The NEC is permitted as an open-book reference. Permanent tabs and pen highlighting are allowed, but repositionable tabs, sticky notes and handwritten notes are not, and you cannot mark the book during the exam.

What experience is required?

Arkansas requires completion of an approved apprenticeship or equivalent documented experience working under a licensed electrician.