PracticeBlogFlashcardsEspañol
All Practice Exams

100+ Free AR Electrician Practice Questions

Pass your Arkansas Journeyman Electrician License Exam exam on the first try — instant access, no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
~55% Pass Rate
100+ Questions
100% Free
1 / 100
Question 1
Score: 0/0

According to the NEC 2023 as adopted by Arkansas, what is the definition of a 'branch circuit'?

A
B
C
D
to track
2026 Statistics

Key Facts: AR Electrician Exam

70%

Passing Score

AR DLL

80

Questions

4-hour limit

$50-75

Exam Fee

PSI

NEC 2023

Code Edition

AR DLL

Arkansas requires passing a journeyman electrician exam based on the NEC 2023. The PSI-administered exam has 80 questions, a 4-hour time limit, and requires 70% to pass. The exam fee is approximately $50-75. Arkansas requires documented experience under a licensed electrician.

Sample AR Electrician Practice Questions

Try these sample questions to test your AR Electrician exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1According to the NEC 2023 as adopted by Arkansas, what is the definition of a 'branch circuit'?
A.The circuit conductors between the final overcurrent device and the outlet(s)
B.The circuit conductors between the service point and the main disconnect
C.The circuit conductors between the transformer and the service entrance
D.The circuit conductors between two panelboards
Explanation: Per NEC Article 100, a branch circuit is defined as the circuit conductors between the final overcurrent device protecting the circuit and the outlet(s). This is fundamental to understanding electrical system layout.
2Under Arkansas's NEC 2023 adoption, what is the definition of a 'continuous load'?
A.A load operating for 1 hour or more
B.A load where maximum current continues for 3 hours or more
C.Any load that operates continuously
D.A load exceeding 80% of circuit capacity
Explanation: Per NEC Article 100, a continuous load is one where the maximum current is expected to continue for 3 hours or more. This affects sizing of conductors and overcurrent devices.
3Per the NEC 2023 as adopted in Arkansas, what is the minimum headroom required for working spaces about electrical equipment rated 600V or less?
A.6 feet
B.6 feet 3 inches
C.6 feet 6 inches
D.7 feet
Explanation: Per NEC Section 110.26(A)(3), the minimum headroom for working spaces around electrical equipment rated 600V or less is 6 feet 6 inches (6.5 feet), or the height of the equipment, whichever is greater.
4According to the NEC 2023 adopted by Arkansas, what is the required working space width in front of electrical equipment?
A.24 inches minimum
B.30 inches or the width of the equipment, whichever is greater
C.36 inches minimum
D.48 inches minimum
Explanation: Per NEC Section 110.26(A)(2), the working space width must be at least 30 inches or the width of the equipment, whichever is greater.
5Per NEC 2023 in Arkansas, what is the minimum depth of working space for Condition 1 at 0-150V to ground?
A.2.5 feet
B.3 feet
C.3.5 feet
D.4 feet
Explanation: Per NEC Table 110.26(A)(1), Condition 1 (exposed live parts on one side only) for equipment rated 0-150V to ground requires a minimum working space depth of 3 feet.
6In Arkansas, what is the minimum trade size for EMT per the NEC?
A.1/4 inch
B.3/8 inch
C.1/2 inch
D.3/4 inch
Explanation: Per NEC Section 358.20(A), the minimum trade size for EMT is 1/2 inch (metric designator 16).
7Per the NEC 2023 adopted in Arkansas, what is the maximum height for the center of a disconnect handle?
A.5 feet 6 inches
B.6 feet
C.6 feet 7 inches
D.7 feet
Explanation: Per NEC Section 404.8(A), the center of the operating handle must not be more than 6 feet 7 inches (2.0 m) above the floor when in its highest position.
8Per NEC 2023 in Arkansas, what is the maximum flexible cord length for a garbage disposal?
A.18-36 inches
B.24-48 inches
C.12-24 inches
D.36-60 inches
Explanation: Per NEC Section 422.16(B)(1), a cord-connected garbage disposal must use a flexible cord between 18 and 36 inches in length.
9Under Arkansas's NEC adoption, what is the minimum conductor size for a 20-ampere branch circuit?
A.14 AWG copper
B.12 AWG copper
C.10 AWG copper
D.8 AWG copper
Explanation: Per NEC Section 210.3 and Table 210.3, a 20-ampere branch circuit requires a minimum of 12 AWG copper.
10Per the NEC 2023 in Arkansas, what is the minimum conductor size for a 15-ampere branch circuit?
A.18 AWG
B.16 AWG
C.14 AWG copper
D.12 AWG copper
Explanation: Per NEC Section 210.3, the minimum conductor size for a 15-ampere branch circuit is 14 AWG copper.

About the AR Electrician Exam

The Arkansas journeyman electrician exam is administered by PSI on behalf of the Arkansas Department of Labor and Licensing. It tests NEC 2023 knowledge including electrical theory, wiring methods, grounding and bonding, load calculations, and Arkansas-specific amendments across 80 multiple-choice questions.

Questions

80 scored questions

Time Limit

4 hours

Passing Score

70%

Exam Fee

$50-75 (Arkansas Dept. of Labor & Licensing)

AR Electrician Exam Content Outline

25%

Wiring Methods & Materials

Raceways, cables, conduit fill, conductor ampacity, and NEC Chapter 3 requirements

20%

Grounding & Bonding

Article 250, grounding electrode systems, equipment grounding, bonding

20%

Branch Circuits & Overcurrent Protection

Conductor sizing, GFCI/AFCI, receptacle spacing, overcurrent devices

20%

Load Calculations & Services

Dwelling and commercial calculations, demand factors, service entrance, feeders

15%

Motors, Special Occupancies & NEC General

Motor circuits, transformers, hazardous locations, healthcare, pools, NEC definitions

How to Pass the AR Electrician Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 80 questions
  • Time limit: 4 hours
  • Exam fee: $50-75

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

AR Electrician Study Tips from Top Performers

1Master NEC Article 250 (Grounding and Bonding) — heavily tested on every state exam
2Practice dwelling unit load calculations per NEC Article 220
3Memorize conductor ampacity from Table 310.16 at 75°C
4Study conduit fill using NEC Chapter 9 tables
5Review motor circuit requirements in Article 430

Frequently Asked Questions

What NEC edition does Arkansas use?

Arkansas uses the NEC 2023 edition for the journeyman electrician licensing exam, adopted by the Arkansas Dept. of Labor & Licensing.

Who administers the Arkansas electrician exam?

The exam is administered by PSI on behalf of the Arkansas Dept. of Labor & Licensing. Schedule through PSI after application approval.

Is the exam open book?

Yes, most PSI-administered electrical exams allow a bound copy of the NEC 2023. No loose papers or handwritten notes permitted.

What experience is required?

Arkansas requires completion of an approved apprenticeship or equivalent documented experience working under a licensed electrician.